A 3D navigation template for guiding a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation: a study protocol for multicentre randomised controlled trials

被引:10
|
作者
Shao, Zhen-Xuan [1 ,2 ]
He, Wei [3 ]
He, Shao-Qi [4 ]
Lin, Sheng-Lei [5 ]
Huang, Zhe-Yu [6 ]
Tang, Hong-Chao [7 ]
Ni, Wen-Fei [1 ,2 ]
Wang, Xiang-Yang [1 ,2 ]
Wu, Ai-Min [1 ,2 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Orthopaed Hosp, Dept Spine Surg, Wenzhou, Peoples R China
[2] Wenzhou Med Univ, Yuying Childrens Hosp, Med Sch 2, Zhejiang Spine Ctr, Wenzhou, Peoples R China
[3] Zhejiang Univ, Peoples Hosp Shaoxing, Dept Orthopaed, Shaoxing Hosp, Shaoxing, Peoples R China
[4] Wenzhou Med Univ, Affiliated Hosp 3, Dept Orthopaed, Peoples Hosp Ruian, Ruian, Peoples R China
[5] Wenzhou Med Univ, Dept Orthopaed, Wenzhou Ctr Hosp, Dingli Hosp, Wenzhou, Peoples R China
[6] Ningbo 6 Hosp, Dept Orthopaed, Ningbo, Zhejiang, Peoples R China
[7] Jiaxing Hosp Zhejiang Gen Corps Armed Police Forc, Dept Orthopaed, Jiaxing, Peoples R China
来源
BMJ OPEN | 2017年 / 7卷 / 07期
基金
中国国家自然科学基金;
关键词
INTERBODY FUSION; SPINAL STENOSIS; PLACEMENT; GUIDANCE; DISEASE;
D O I
10.1136/bmjopen-2017-016328
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The incidence of lumbar disc degeneration disease has increased in recent years. Lumbar interbody fusion using two unilateral pedicle screws and a translaminar facet screw fixation has advantages of minimal invasiveness and lower costs compared with the traditional methods. Moreover, a method guided by a three-dimensional (3D) navigation template may help us improve the surgical accuracy and the success rate. This is the first randomised study using a 3D navigation template to guide a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation. Methods and analysis Patients who meet the criteria of the surgery will be randomly divided into experimental groups and control groups by a computer-generated randomisation schedule. We will preoperatively design an individual 3D navigation template using CATIA software and MeditoolCreate. The following primary outcomes will be collected: screw angles compared with the optimal screw trajectories in 3D digital images, length of the wound incision, operative time, intraoperative blood loss and complications. The following secondary outcomes will be collected: visual analogue scale (VAS) for back pain, VAS for leg pain and the Oswestry Disability Index. These parameters will be evaluated on day 1 and then 3, 6, 12 and 24 months postoperatively. Ethics and dissemination The study has been reviewed and approved by the institutional ethics review board of the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University. The results will be presented at scientific communities and peer-reviewed journals.
引用
收藏
页数:7
相关论文
共 20 条
  • [1] Innovative 3D Navigation Module for Precise Unilateral Pedicle Screw Combined with Contralateral Translaminar Facet Screw Placement in Lumbar Spine Surgery
    Chen, Xu
    Dai, Hanhao
    Luo, Jun
    Zhang, Huaizhi
    Song, Chao
    Deng, Zhibo
    Zhang, Yanyan
    Li, Xing
    Dai, Jianhui
    Xu, Jie
    ORTHOPAEDIC SURGERY, 2024, 16 (12) : 3026 - 3035
  • [2] Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
    Guo, Fei
    Dai, Jianhao
    Zhang, Junxiang
    Ma, Yichuan
    Zhu, Guanghui
    Shen, Junjie
    Niu, Guoqi
    PLOS ONE, 2017, 12 (02):
  • [3] Unilateral versus bilateral pedicle screw fixation in short-segment lumbar spinal fusion: a meta-analysis of randomised controlled trials
    Xin, Zengfeng
    Li, Weixu
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (02) : 355 - 364
  • [4] Combination of Percutaneous Unilateral Translaminar Facet Screw Fixation and Interbody Fusion for Treatment of Lower Lumbar Vertebra Diseases: a Follow-Up Study
    Zeng, Zhong-you
    Zhang, Jian-qiao
    Song, Yong-xin
    Yan, Wei-feng
    Wu, Peng
    Tang, Hong-cao
    Han, Jian-fu
    ORTHOPAEDIC SURGERY, 2014, 6 (02) : 110 - 117
  • [5] How Safe Is Unilateral Pedicle Screw Fixation in Lumbar Fusion Surgery for Management of 2-Level Lumbar Degenerative Disorders Compared with Bilateral Pedicle Screw Fixation? Meta-analysis of Randomized Controlled Trials
    Muthu, Sathish
    Chellamuthu, Girinivasan
    WORLD NEUROSURGERY, 2020, 140 : 357 - 368
  • [6] Design and application of a novel patient-specific 3D printed drill navigational guiding template in percutaneous thoracolumbar pedicle screw fixation: A cadaveric study
    Li, Zhonghai
    Xu, Dingjun
    Li, FengNing
    Liu, Mozhen
    Xu, Gang
    Yang, Ming
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 73 : 294 - 298
  • [7] Clinical Use of 3D Printing Guide Plate in Posterior Lumbar Pedicle Screw Fixation
    Chen, Hongliang
    Wu, Dongying
    Yang, Huilin
    Guo, Kaijin
    MEDICAL SCIENCE MONITOR, 2015, 21 : 3948 - 3954
  • [8] Unilateral versus Bilateral Pedicle Screw Fixation for Degenerative Lumbar Diseases: A Meta-Analysis of 10 Randomized Controlled Trials
    Li, Xianzhou
    Lv, Chaoliang
    Yan, Tingzhen
    MEDICAL SCIENCE MONITOR, 2015, 21 : 782 - 790
  • [9] Minimally invasive unilateral pedicle screws and a translaminar facet screw fixation and interbody fusion for treatment of single-segment lower lumbar vertebral disease: surgical technique and preliminary clinical results
    Huang, Peng
    Wang, Yiguo
    Xu, Jiao
    Xiao, Bo
    Liu, Jianheng
    Che, Luyang
    Mao, Keya
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [10] Cranial facet joint injuries in percutaneous lumbar pedicle screw placement: a matched-pair analysis comparing intraoperative 3D navigation and conventional fluoroscopy
    Hohenhaus, Marc
    Watzlawick, Ralf
    Masalha, Waseem
    Volz, Florian
    Scholz, Christoph
    Hubbe, Ulrich
    Klingler, Jan-Helge
    EUROPEAN SPINE JOURNAL, 2021, 30 (01) : 88 - 96