Tricuspid and Pulmonary Valve Disease Evaluation and Management

被引:15
作者
Shah, Pravin M. [1 ]
机构
[1] Hoag Mem Hosp, Hoag Heart Valve Ctr, Newport Beach, CA USA
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2010年 / 63卷 / 11期
关键词
Tricuspid regurgitation; Tricuspid valve repair; Pulmonary stenosis; Percutaneous pulmonary valve replacement; BALLOON VALVULOPLASTY; EXERCISE CAPACITY; MIDTERM OUTCOMES; RISK-FACTORS; REGURGITATION; IMPLANTATION; STENOSIS; REPAIR; REPLACEMENT; SEVERITY;
D O I
10.1016/S0300-8932(10)70304-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The clinical detection and quantification of tricuspid valve disease, although important, is not entirely accurate. Diagnostic evaluation is based on echocardiography, and color flow Doppler is useful for quantifying tricuspid regurgitation. Echocardiography provides information on heart chamber dimensions, right ventricular function, and the degree of pulmonary hypertension. In addition, tricuspid stenosis can be accurately assessed using mean and end-diastolic pressure gradient measurements. The treatment options for tricuspid stenosis include balloon valvuloplasty and surgical valve repair. Functional tricuspid regurgitation associated with left heart disease may require surgical attention during an operation to treat the left heart disease. Severe tricuspid regurgitation usually requires surgery to be performed in association with mitral valve surgery. Mild-to-moderate tricuspid regurgitation requires surgery when annular dilatation or severe pulmonary hypertension is present. The surgical options include tricuspid valve repair, with or without an annuloplasty ring. In patients with a primary anatomic deformity of the tricuspid valve, replacement of the valve with a bioprosthesis or mechanical valve may be considered. Intermediate and long-term results favor annuloplasty valve repair over valve replacement. Pulmonary valve disease is predominantly congenital, and generally takes the form of pulmonary stenosis. Pulmonary regurgitation often results from surgical or balloon valvuloplasty and is associated with deleterious long-term sequelae. The recent development of percutaneous valve replacement was a major advance.
引用
收藏
页码:1349 / 1365
页数:17
相关论文
共 38 条
  • [11] Tricuspid valve surgery: a thirty-year assessment of early and late outcome
    Guenther, Thomas
    Noebauer, Christian
    Mazzitelli, Domenico
    Busch, Raymonde
    Tassani-Prell, Peter
    Lange, Ruediger
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (02) : 402 - 409
  • [12] LONG-TERM PULMONARY REGURGITATION FOLLOWING BALLOON VALVULOPLASTY FOR PULMONARY STENOSIS: RISK FACTORS AND RELATIONSHIP TO EXERCISE CAPACITY AND VENTRICULAR VOLUME AND FUNCTION
    Harrild, David M.
    Powell, Andrew J.
    Trang, X. Trang
    Geva, Tal
    Lock, James E.
    Rhodes, Jonathan
    McElhinney, Doff B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) : 1041 - 1047
  • [13] Joudinaud TM, 2006, J HEART VALVE DIS, V15, P382
  • [14] Percutaneous pulmonary valve implantation in humans - Results in 59 consecutive patients
    Khambadkone, S
    Coats, L
    Taylor, A
    Boudjemline, Y
    Derrick, G
    Tsang, V
    Cooper, J
    Muthurangu, V
    Hegde, SR
    Razavi, RS
    Pellerin, D
    Deanfield, J
    Bonhoeffer, P
    [J]. CIRCULATION, 2005, 112 (08) : 1189 - 1197
  • [15] Total resection and complete reconstruction of the tricuspid valve in acute infective endocarditis
    Konstantinov, Igor E.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (02) : 531 - 532
  • [16] Edge-to-edge tricuspid valve repair: An adjuvant technique for residual tricuspid regurgitation
    Lai, Yong-Qiang
    Meng, Xu
    Bai, Tao
    Zhang, Chun
    Luo, Yi
    Zhang, Zhao-Guang
    [J]. ANNALS OF THORACIC SURGERY, 2006, 81 (06) : 2179 - 2182
  • [17] Balloon Pulmonary Valvuloplasty, Pulmonary Regurgitation, and Exercise Capacity The Good, the Bad, and the Not Yet Clear
    Latson, Larry A.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) : 1048 - 1049
  • [18] Percutaneous pulmonary valve implantation impact of evolving technology and learning curve on clinical outcome
    Lurz, Philipp
    Coats, Louise
    Khambadkone, Sachin
    Nordmeyer, Johannes
    Boudjemline, Younes
    Schievano, Silvia
    Muthurangu, Vivek
    Lee, Twin Yen
    Parenzan, Giovanni
    Derrick, Graham
    Cullen, Seamus
    Walker, Fiona
    Tsang, Victor
    Deanfield, John
    Taylor, Andrew M.
    Bonhoeffer, Philipp
    [J]. CIRCULATION, 2008, 117 (15) : 1964 - 1972
  • [19] Tricuspid valve repair: Durability and risk factors for failure
    McCarthy, PM
    Bhudia, SK
    Rajeswaran, J
    Hoercher, KJ
    Lytle, BW
    Cosgrove, DM
    Blackstone, EH
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (03) : 674 - 685
  • [20] Prognosis of carcinoid heart disease - Analysis of 200 cases over two decades
    Moller, JE
    Pellikka, PA
    Bernheim, AM
    Schaff, HV
    Rubin, J
    Connolly, HM
    [J]. CIRCULATION, 2005, 112 (21) : 3320 - 3327