Experimental Study of Suppressing Vertical PS Fires Using Water Spray

被引:0
作者
Zhao, Hengze [1 ]
Zhang, Yongming [1 ]
Hu, Haibing [1 ]
Zhao, Lanming [1 ]
机构
[1] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
来源
ENGINEERING AND MANUFACTURING TECHNOLOGIES | 2014年 / 541-542卷
关键词
water spray; suppression; EPS and XPS material; vertical fire;
D O I
10.4028/www.scientific.net/AMM.541-542.1403
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Water suppression experiments of EPS and XPS are conducted in Standard Combustion Chamber in USTC in Hefei. The 20 cm * 20 cm PSs were held against a 600 mm*600 mm vertical gypsum board fixed by a steel frame structures to simulate a building facade. A series of results have been obtained. When the water spray is not applied, the EPS is easier to melt, drip and pyrolyze than XPS under the same fire load, but causes less amount of CO than the amount of XPS without any water application. When the water is applied, neither EPS nor XPS has a trend to drip. The amount of CO caused by EPS or XPS under water spray is much less than that of non-spray. Also the extinguishment time falls fast once the PS materials are applied with water. In addition, these experimental results demonstrate the feasibility of the designed rig in studying the fire suppression on vertical PS materials using water spray.
引用
收藏
页码:1403 / 1407
页数:5
相关论文
共 50 条
  • [21] Experimental and numerical study on attenuation of thermal radiation from large-scale pool fires by water mist curtain
    Zhu, Pei
    Wang, Xishi
    Wang, Zhigang
    Cong, Haiyong
    Ni, Xiaomin
    JOURNAL OF FIRE SCIENCES, 2015, 33 (04) : 269 - 289
  • [22] Reignition of cable tray fires induced by the suppression of the water spray using horizontally arranged nozzles:A full-scale fire experiment and numerical simulation
    Huang, Xianjia
    Wang, Jinlong
    Wang, Zengchen
    Wen, Jing
    Peng, Lan
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 210
  • [23] Experimental study on turbulent mixing of spray droplets in crossflow
    Bai, Bo-Feng
    Zhang, Hai-Bin
    Liu, Li
    Sun, Hui-Juan
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (06) : 1012 - 1020
  • [24] A numerical study of the interaction of water spray with a fire plume
    Hua, JS
    Kumar, K
    Khoo, BC
    Xue, H
    FIRE SAFETY JOURNAL, 2002, 37 (07) : 631 - 657
  • [25] Experimental study on the influence of the water spray cooling on air-cooled condenser of the split-type air conditioner
    Charoensin-O-larn, Roytor
    Kavee, Narin
    Klinbun, Jirapol
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [26] Experimental evaluation of individual effects of water mist spray characteristics on thermal radiation attenuation using twin-fluid nozzles with full-cone spray pattern
    Jo, Jae Geun
    Lee, Chi Young
    PROCESS SAFETY PROGRESS, 2023, 42 (01) : 141 - 154
  • [27] AN IMPROVED SOLUTION FOR SHIELDING OF THERMAL RADIATION OF FIRES USING MIST CURTAINS OF PURE WATER OR SEA WATER
    Dombrovsky, Leonid A.
    Dembele, Siaka
    PROCEEDINGS OF CHT-21 ICHMT INTERNATIONAL SYMPOSIUM ON ADVANCES IN COMPUTATIONAL HEAT TRANSFER, 2021, 2021,
  • [28] Stair phenomenon study in spectrum infrared transmission of water spray
    Chen Zhong-wei
    Zhang Li
    Liang Chao
    Wang Hong-bin
    Zhang Ling-jiang
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: INFRARED IMAGING AND APPLICATIONS, 2013, 8907
  • [29] Experimental study on fire smoke control using water mist curtain in channel
    Wang, Zhigang
    Wang, Xishi
    Huang, Yanqing
    Tao, Changfa
    Zhang, Heping
    JOURNAL OF HAZARDOUS MATERIALS, 2018, 342 : 231 - 241
  • [30] Parametric study of design fires for tunnels with water-based fire suppression systems
    Li, Ying Zhen
    Ingason, Haukur
    FIRE SAFETY JOURNAL, 2021, 120