Point-of-Care Cerebrospinal Fluid Detection

被引:14
|
作者
Kita, Ashley E. [1 ]
Bradbury, Daniel W. [2 ]
Taylor, Zachary D. [2 ,3 ,4 ]
Kamei, Daniel T. [2 ]
St John, Maie A. [1 ,3 ,5 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Head & Neck Surg, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Henry Samueli Sch Engn & Appl Sci, Los Angeles, CA USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, UCLA Head & Neck Canc Program, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Dept Surg, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Jonsson Comprehens Canc Ctr, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院;
关键词
cerebrospinal fluid leak; semiquantitative; lateral-flow immunoassay; diagnostic; point of care; otolaryngology; beta-trace protein; BETA-TRACE PROTEIN; PROSTAGLANDIN-D SYNTHASE; RHINORRHEA; COMPLICATIONS; DIAGNOSIS; OTORRHEA; SERUM; SURGERY; LEAKAGE; MARKER;
D O I
10.1177/0194599818789075
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective A cerebrospinal fluid leak is one of the most serious complications in otolaryngology. It may occur as a result of injury to the skull base, typically traumatic or iatrogenic. While the presence of a leak is often discerned in the emergent setting, distinguishing normal secretions from those containing cerebrospinal fluid can be difficult during postoperative visits in the clinic. As most current laboratory-based assays are labor intensive and require several days to result, we aim to develop a more user-friendly and rapid point-of-care cerebrospinal fluid detection device. Study Design Our laboratory developed a barcode-style lateral-flow immunoassay utilizing antibodies for beta-trace protein, a protein abundant in and specific for cerebrospinal fluid, with a concentration of 1.3 mg/L delineating a positive result. Setting Tertiary medical center. Subjects and Methods Tests with known concentrations of resuspended beta-trace protein and the contents of discarded lumbar drains (presumed to contain cerebrospinal fluid) were performed to validate our novel device. Results Our results demonstrate the ability of our device to semiquantitatively identify concentrations of beta-trace protein from 0.3-90 mg/L, which is within the required range to diagnose a leak, thus making beta-trace protein an excellent target for rapid clinical detection. Conclusion Herein we detail the creation and initial validation of the first point-of-care cerebrospinal fluid detection device. This device is a feasible method to more efficiently and cost-effectively identify cerebrospinal fluid leaks, minimize costs, and improve patient outcomes.
引用
收藏
页码:824 / 829
页数:6
相关论文
共 50 条
  • [31] Developments in Point-of-Care Diagnostic Technology for Cancer Detection
    Hayes, Bryony
    Murphy, Caroline
    Crawley, Aoife
    O'Kennedy, Richard
    DIAGNOSTICS, 2018, 8 (02):
  • [32] Interfacing Pathogen Detection with Smartphones for Point-of-Care Applications
    Ding, Xiong
    Mauk, Michael G.
    Yin, Kun
    Kadimisetty, Karteek
    Liu, Changchun
    ANALYTICAL CHEMISTRY, 2019, 91 (01) : 655 - 672
  • [33] A Lateral Flow Device for Point-of-Care Detection of Doxorubicin
    Pomili, Tania
    Gatto, Francesca
    Pompa, Pier Paolo
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [34] Point-of-Care Sonographic Detection of Intestinal Ascaris lumbricoides in the Pediatric Emergency Department
    Kessler, David O.
    Gurwitz, Avrahom
    Tsung, James W.
    PEDIATRIC EMERGENCY CARE, 2010, 26 (08) : 586 - 587
  • [35] Recombinase polymerase amplification: a promising point-of-care detection method for enteric viruses
    Moore, Matthew D.
    Jaykus, Lee-Ann
    FUTURE VIROLOGY, 2017, 12 (08) : 421 - 429
  • [36] Detection of Cannabinoids in Oral Fluid Specimens as the Preferred Biological Matrix for a Point-of-Care Biosensor Diagnostic Device
    Trif, Calin
    Harpaz, Dorin
    Eltzov, Evgeni
    Parcharoen, Yardnapar
    Pechyen, Chiravoot
    Marks, Robert S.
    BIOSENSORS-BASEL, 2024, 14 (03):
  • [37] Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2
    Ke, Chiao-Hsu
    Du, Mao-Yuan
    Hsieh, Wang-Ju
    Lin, Chiu-Chiao
    Ting, James Mingjuh
    Chiou, Ming-Tang
    Lin, Chao-Nan
    JOURNAL OF VETERINARY SCIENCE, 2024, 25 (02)
  • [38] Methods of Respiratory Virus Detection: Advances towards Point-of-Care for Early Intervention
    Lu, Siming
    Lin, Sha
    Zhang, Hongrui
    Liang, Liguo
    Shen, Shien
    MICROMACHINES, 2021, 12 (06)
  • [39] Magneto-nanosensor smartphone platform for the detection of HIV and leukocytosis at point-of-care
    Ng, Elaine
    Yao, Chengyang
    Shultz, Tyler O.
    Ross-Howe, Sara
    Wang, Shan X.
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2019, 16 : 10 - 19
  • [40] Evaluation of a point-of-care immunoassay test kit 'StrongStep' for cryptococcal antigen detection
    Mpoza, Edward
    Mukaremera, Liliane
    Kundura, Didas Atwebembere
    Akampurira, Andrew
    Luggya, Tonny
    Tadeo, Kiiza Kandole
    Pastick, Katelyn A.
    Bridge, Sarah C.
    Tugume, Lillian
    Kiggundu, Reuben
    Musubire, Abdu K.
    Williams, Darlisha A.
    Muzoora, Conrad
    Nalintya, Elizabeth
    Rajasingham, Radha
    Rhein, Joshua
    Boulware, David R.
    Meya, David B.
    Abassi, Mahsa
    PLOS ONE, 2018, 13 (01):