Experimental Study on Seismic Performance of Precast Pretensioned Prestressed Concrete Beam-Column Interior Joints Using UHPC for Connection

被引:11
作者
Xiong, Xueyu [1 ,2 ]
Xie, Yifan [1 ]
Yao, Gangfeng [3 ]
Liu, Ju [1 ]
Yan, Laizhang [4 ]
He, Liang [5 ]
机构
[1] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Key Lab Adv Civil Engn Mat, Shanghai 200092, Peoples R China
[3] Suzhou Univ Sci & Technol, Sch Civil Engn, Suzhou 215011, Peoples R China
[4] China Railway 24th Construct Bur Anhui Engn Co Lt, Hefei 230011, Peoples R China
[5] China Construct Sci & Technol Grp East China Co L, Shanghai 200126, Peoples R China
基金
中国国家自然科学基金;
关键词
UHPC; precast pretensioned beam-column interior joint; seismic performance; anchoring length of strands; BOND; BEHAVIOR; REINFORCEMENT; BARS; STRENGTH;
D O I
10.3390/ma15165791
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The traditional connections and reinforcement details of precast RC frames are complex and cause difficulty in construction. Ultra-high-performance concrete (UHPC) exhibits outstanding compressive strength and bond strength with rebars and strands; thus, the usage of UHPC in the joint core area will reduce the amount of transverse reinforcement and shorten the anchoring length of beam rebars as well as strands significantly. Moreover, the lap splice connections of precast columns can be placed in the UHPC joint zone and the construction process will be simplified. This paper presented a novel joint consisting of a precast pretensioned prestressed concrete beam, an ordinary precast reinforced concrete (RC) column, and a UHPC joint zone. To study the seismic performance of the proposed joints, six novel interior joints and one monolithic RC joint were tested under low-cyclic loads. Variables such as the axial force, the compressive strength of UHPC, the stirrup ratio were considered in the tests. The test results indicate that the proposed joints exhibit comparable seismic performance of the monolithic RC joint. An anchorage length of 40 times the strands-diameter and a lap splice length of 16 times the rebar-diameter are adequate for prestressed strands and precast column rebars, respectively. A minimum column depth is suggested as 13 times the diameter of the beam-top continuous rebars passing through the joint. In addition, a nine-time rebar diameter is sufficient for the anchorage of beam bottom rebars. The shear strength of UHPC in the joint core area is suggested as 0.8 times the square root of the UHPC compressive strength.
引用
收藏
页数:27
相关论文
共 54 条
  • [1] Factors affecting bond development between Ultra High Performance Concrete (UHPC) and steel bar reinforcement
    Alkaysi, Mo
    El-Tawil, Sherif
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 144 : 412 - 422
  • [2] [Anonymous], 2006, NZS3101 2006
  • [3] [Anonymous], 2004, 1992 1 2 EC 2
  • [4] [Anonymous], 2005, ACI Committee 374
  • [5] [Anonymous], 2015, DGJ08 69 2015
  • [6] [Anonymous], 2015, GB50010 2010
  • [7] [Anonymous], 2002, ACI 352R 02
  • [8] [Anonymous], 2019, Aci 318-19
  • [9] [Anonymous], 2016, JGJ369 2016
  • [10] Bond stress between conventional reinforcement and steel fibre reinforced reactive powder concrete
    Bae, Baek-Il
    Choi, Hyun-Ki
    Choi, Chang-Sik
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 112 : 825 - 835