Effect of Drilling Fluid Systems and Temperature on Oil Mist and Vapour Levels Generated from Shale Shaker

被引:8
作者
Steinsvag, Kjersti [1 ]
Galea, Karen S. [2 ]
Kruger, Kirsti [1 ]
Peikli, Vegard [1 ]
Sanchez-Jimenez, Araceli [2 ]
Saetvedt, Esther [1 ]
Searl, Alison [2 ]
Cherrie, John W. [2 ]
Van Tongeren, Martie [2 ]
机构
[1] Statoil ASA, NO-0243 Oslo, Norway
[2] Inst Occupat Med, Edinburgh EH14 4AP, Midlothian, Scotland
关键词
drilling fluids; exposure determinants; offshore petroleum industry; oil mist; oil vapour; CABLE MANUFACTURING COMPANY; EXPOSURE CONDITIONS; WORKERS; MORTALITY; CANCER;
D O I
10.1093/annhyg/meq097
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Workers in the drilling section of the offshore petroleum industry are exposed to air pollutants generated by drilling fluids. Oil mist and oil vapour concentrations have been measured in the drilling fluid processing areas for decades; however, little work has been carried out to investigate exposure determinants such as drilling fluid viscosity and temperature. A study was undertaken to investigate the effect of two different oil-based drilling fluid systems and their temperature on oil mist, oil vapour, and total volatile organic compounds (TVOC) levels in a simulated shale shaker room at a purpose-built test centre. Oil mist and oil vapour concentrations were sampled simultaneously using a sampling arrangement consisting of a Millipore closed cassette loaded with glass fibre and cellulose acetate filters attached to a backup charcoal tube. TVOCs were measured by a PhoCheck photo-ionization detector direct reading instrument. Concentrations of oil mist, oil vapour, and TVOC in the atmosphere surrounding the shale shaker were assessed during three separate test periods. Two oil-based drilling fluids, denoted 'System 2.0' and 'System 3.5', containing base oils with a viscosity of 2.0 and 3.3-3.7 mm(2) s(-1) at 40 degrees C, respectively, were used at temperatures ranging from 40 to 75 degrees C. In general, the System 2.0 yielded low oil mist levels, but high oil vapour concentrations, while the opposite was found for the System 3.5. Statistical significant differences between the drilling fluid systems were found for oil mist (P = 0.025),vapour (P < 0.001), and TVOC (P = 0.011). Increasing temperature increased the oil mist, oil vapour, and TVOC levels. Oil vapour levels at the test facility exceeded the Norwegian oil vapour occupational exposure limit (OEL) of 30 mg m(-3) when the drilling fluid temperature was >= 50 degrees C. The practice of testing compliance of oil vapour exposure from drilling fluids systems containing base oils with viscosity of <= 2.0 mm(2) s(-1) at 40 degrees C against the Norwegian oil vapour OEL is questioned since these base oils are very similar to white spirit. To reduce exposures, relevant technical control measures in this area are to cool the drilling fluid <50 degrees C before it enters the shale shaker units, enclose shale shakers and related equipment, in addition to careful consideration of which fluid system to use.
引用
收藏
页码:347 / 356
页数:10
相关论文
共 18 条
[1]  
ACGIH, 1992, DOC THRESH LIM VAL B
[2]  
ARNESEN U, 1985, ARBETE HALSA, V13, P1
[3]   Modeling of Oil Mist and Oil Vapor Concentration in the Shale Shaker Area on Offshore Drilling Installations [J].
Bratveit, Magne ;
Steinsvag, Kjersti ;
Lie, Stein Atle ;
Moen, Bente E. .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2009, 6 (11) :679-686
[5]  
Galea KS, 2010, TM1001 IOM
[6]  
HAUG E, 1988, REVISJON LOSEMIDDELN
[7]   Improving the working environment and drilling economics through better understanding of oil-based drilling fluid chemistry [J].
James, RW ;
Schel, T ;
Navestad, P ;
Geddes, TA ;
Nelson, MG ;
Webster, D .
SPE DRILLING & COMPLETION, 2000, 15 (04) :254-260
[8]  
MALVIK B, 1988, STF21A88028
[9]  
*NIOSH, 1996, 5026 NIOSH
[10]  
NIOSH National Institute on Occupational Safety and Health, 2003, 1500 NIOSH