Comparison of erythrocyte sedimentation rate measurement by the automated SEDIsystem™ and conventional Westergren method using the Bland and Altman statistical method

被引:15
作者
AlFadhli, SM [1 ]
Al-Awadhi, AM [1 ]
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Med Lab Sci, Sulibikhat 90805, Kuwait
关键词
erythrocyte sedimentation rate; SEDIsystem (TM); Westergren method;
D O I
10.1159/000085742
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the performance of SEDIsystemTM, a fully automated analyzer for the measurement of the erythrocyte sedimentation rate ( ESR), with the manual Westergren method. Materials and Methods: Both methods were applied to 150 randomly selected subjects. The linear regression and Bland and Altman data analysis methods were used to measure the agreement between the automated and manual methods. Results: The regression analysis showed a good correlation between the two methods ( r = 0.91). The Bland and Altman data analysis showed no systematic bias ( 95% confidence interval for mean difference); however, limits of agreement were between 11.52 and - 37.88. This indicates that ESR values measured by the SEDIsystem may be 11.52 mm/ h above or 37.88 mm/ h below the reference method. A greater scatter of data was also observed with abnormally high ( 1 25 mm/ h) ESR results ( mean of difference = - 21.4 and limits of agreement = - 45.2 and 2.26) compared with normal ( < 25 mm/ h) readings ( mean of difference = - 3.9 and limits of agreement = - 13.5 and 5.7). Conclusion: The Bland and Altman statistical analysis showed a wide degree of scatter between results obtained by the two ESR techniques that was not clearly demonstrated using the linear regression analysis. The automated system was found to underestimate ESR with the Bland and Altman statistical analysis, and therefore a correction factor is recommended. Copyright (C) 2005 S. Karger AG, Basel.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 1921, Acta. Med. Scand, DOI [10.1152/physrev.1929.9.2.241, DOI 10.1111/J.0954-6820.1921.TB15179.X]
[2]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Comparison of the erythrocyte sedimentation rate measured in the eye casualty department by the Seditainer method with an automated system [J].
Browning, AC ;
Burbidge, AA ;
Hodgkins, PR .
EYE, 1999, 13 (6) :754-757
[5]  
BULL BS, 1993, J CLIN PATHOL, V46, P198
[6]  
Dewitte K, 2002, CLIN CHEM, V48, P799
[7]  
Happe MR, 2002, AM J CLIN PATHOL, V118, P14
[8]  
Imafuku Y, 1998, HEMATOL CELL THER, V40, P27
[9]  
Kallner Anders, 1994, Upsala Journal of Medical Sciences, V99, P179
[10]  
Lewis SM, 2001, DACIE LEWIS PRACTICA, P527