Polystyrene-divinylbenzene-glycidyl methacrylate stationary phase grafted with poly (amidoamine) dendrimers for ion chromatography

被引:32
|
作者
Guo, Dandan [1 ]
Lou, Chaoyan [1 ]
Zhang, Peimin [1 ]
Zhang, Jiajie [1 ]
Wang, Nani [1 ,2 ]
Wu, Shuchao [3 ]
Zhu, Yan [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Xixi Campus, Hangzhou 310028, Zhejiang, Peoples R China
[2] Zhejiang Acad Tradit Chinese Med, Dept Med, Hangzhou, Zhejiang, Peoples R China
[3] Zhejiang Inst Geol & Mineral Resources, Hangzhou 310007, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Ion chromatography; Poly amidoamine dendrimers; Grafting stationary phase; Inorganic anions; Carbohydrates; ANION-EXCHANGERS; SEPARATION; PAMAM; PERFORMANCE;
D O I
10.1016/j.chroma.2016.05.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a novel ion exchange stationary phase based on different generations of poly (amidoamine) dendrimers (PAMAM) was developed for the determination of inorganic anions and carbohydrates. Synthesis of the PAMAM was carried out with the polymerization reaction of ethylenediamine and methyl acrylate. The synthesized PAMAM was then grafted to the polystyrene-divinylbenzene-glycidyl methacrylate (PS-GMA) to form PAMAM-based beads. These beads were finally modified with 1,4-butanediol diglycidyl ether (BDDE) to generate the anion exchanger, which were characterized by scanning electron microscopy (SEM), brunauer-emmett-teller (BET), fourier transform infrared spectroscopy (FTIR), and elemental analysis. Elemental analysis, breakthrough curves and capacity factors showed that more epoxy groups and higher PAMAM generations in stationary phase could result in higher anion exchange capacity. The efficiency, durability and stability of the proposed anion exchanger were investigated by using six inorganic anions (fluoride, chloride, nitrite, bromide, nitrate and sulfate) and four carbohydrates (trehalose, glucose, maltotriose and galacturonic acid) as analytes, respectively. The reliability of the proposed ion chromatographic stationary phase was demonstrated by determining the content of galacturonic acid in polysaccharides from Poria cocos and Atractylodes macrocephala. The relative standard deviations of retention time, peak height, and peak area for galacturonic acid were 0.39%, 1.22%, and 2.02%, respectively. The spiked recoveries were in the range of 88.29%-100.51% for plant polysaccharides. Due to the good structural homogeneity, intense internal porosity, biological compatibility and high density of active groups in PAMAM, this grafted stationary phase showed good ion-exchange characteristics, especially in biological charged molecules. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 23 条
  • [1] The polystyrene-divinylbenzene stationary phase modified with poly (Amine-Epichlorohydrin) for ion chromatography
    Huang, Zhongping
    Zhuge, Chun
    Zhu, Qiulian
    Liu, Huijun
    She, Yuanbin
    Zhu, Yan
    MICROCHEMICAL JOURNAL, 2020, 155
  • [2] Fabrication of graphene oxide polymer composite particles with grafted poly(amidoamine) dendrimers and their application in ion chromatography
    Guo, Dandan
    Lou, Chaoyan
    Huang, Zhongping
    Muhammad, Nadeem
    Zhao Qiming
    Wu, Shuchao
    Zhu, Yan
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (11) : 8653 - 8660
  • [3] The polystyrene-divinylbenzene stationary phase hybridized with oxidized nanodiamonds for liquid chromatography
    Huang, Zhongping
    Yao, Peng
    Zhu, Qiulian
    Wang, Lili
    Zhu, Yan
    TALANTA, 2018, 185 : 221 - 228
  • [4] Poly(ethylene oxide)-bonded stationary phase for capillary ion chromatography
    Takeuchi, Toyohide
    Oktavia, Budhi
    Lim, Lee Wah
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (04) : 1267 - 1272
  • [5] Fabrication of polyethyleneimine grafted maleopimaric acid glycidyl methacrylate ester stationary phase for mixed-mode liquid chromatography
    Zeng, Lei
    Wu, Huiying
    Jiang, Lijuan
    Li, Hao
    Shi, Boan
    Lei, Fuhou
    MICROCHEMICAL JOURNAL, 2024, 197
  • [6] Poly (styrene-divinyl benzene-glycidylmethacrylate) stationary phase grafted with poly amidoamine (PAMAM) dendrimers for rapid determination of phenylene diamine isomers in HPLC
    Guo, Dandan
    Lou, Chaoyan
    Wang, Nani
    Chen, Meilan
    Zhang, Peimin
    Wu, Shuchao
    Zhu, Yan
    TALANTA, 2017, 168 : 188 - 195
  • [7] Iodide analysis by ion chromatography on a new stationary phase of polystyrene-divinylbenzene agglomerated with polymerized-epichlorohydrin-dimethylamine
    Wang, Mu-Hua
    Huang, Zhong-Ping
    Liu, Jun-Wei
    He, Jie
    Zhang, Jia-Jie
    Zhu, Yan
    CHINESE CHEMICAL LETTERS, 2015, 26 (08) : 1026 - 1030
  • [8] Polystyrene immobilized ionenes as novel stationary phase for ion chromatography
    Raskop, Michael P.
    Grimm, Andreas
    Seubert, Andreas
    MICROCHIMICA ACTA, 2007, 158 (1-2) : 85 - 94
  • [9] Preparation of polystyrene-b-poly(ethylene/propylene)-b-polystyrene grafted glycidyl methacrylate and its compatibility with recycled polypropylene/recycled high impact polystyrene blends
    Kong, Yufei
    Li, Yingchun
    Hu, Guosheng
    Lin, Jing
    Pan, Duo
    Dong, Dongyao
    Wujick, Evan
    Shao, Qian
    Wu, Minjian
    Zhao, Jizhang
    Guo, Zhanhu
    POLYMER, 2018, 145 : 232 - 241
  • [10] Poly(ethylene oxide)-bonded stationary phase for capillary ion chromatography
    Toyohide Takeuchi
    Budhi Oktavia
    Lee Wah Lim
    Analytical and Bioanalytical Chemistry, 2009, 393 : 1267 - 1272