Computed Tomography Density as a Bio-marker for Histologic Grade of Otosclerosis: A Human Temporal Bone Pathology Study

被引:1
|
作者
Quesnel, Alicia M. [1 ]
Ishai, Reuven [3 ]
Meehan, Timothy [4 ]
O'Malley, Jennifer T. [1 ]
Mitchell, Renee [5 ]
Shin, Jennifer J. [2 ]
Curtin, Hugh D. [5 ]
Nadol, Joseph B., Jr. [1 ,2 ]
McKenna, Michael J. [6 ]
Juliano, Amy F. [5 ]
机构
[1] Harvard Med Sch, Dept Otolaryngol Head & Neck Surg, Massachusetts Eye & Ear, Boston, MA 02115 USA
[2] Harvard Med Sch, Dept Otolaryngol Head & Neck Surg, Boston, MA 02115 USA
[3] Ruth & Bruce Rappaport Fac Med, Rambam Hlth Care Campus, Dept ENT, Haifa, Israel
[4] Midwest Radiol, Roseville, MN USA
[5] Harvard Med Sch, Massachusetts Eye & Ear, Dept Radiol, Boston, MA 02115 USA
[6] Akouos Inc, Boston, MA USA
关键词
computed tomography; computed tomography densitometry; computed tomography density; grading; histology; otopathology; otosclerosis; radiology; temporal bone pathology; SENSORINEURAL HEARING-LOSS; HISTOPATHOLOGY; CT; DENSITOMETRY; EXPRESSION; DIAGNOSIS; STAPES;
D O I
10.1097/MAO.0000000000003535
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis Computed tomography (CT) density measurement can be used to objectively distinguish otosclerosis from normal bone and to determine histologic grades of otosclerosis. Background Otosclerosis can be seen on CT as subtle radiolucent areas. An objective radiologic measurement that corresponds to known otosclerosis pathology may improve diagnostic accuracy, and could be used as a radiologic biomarker for otosclerosis grade. Methods A blinded, randomized evaluation of both histologic grade on histopathology slides and CT density measurement was performed on 78 human temporal bone specimens (31 with otosclerosis and 47 controls) that had undergone high-resolution multi-detector CT before histologic processing. Assessments were performed at 11 regions of interest (ROIs) in the otic capsule for each specimen. Results The CT density measurement mean (Hounsfield Units) +/- standard deviation for all ROIs (Nos. 1-9) was 2245 +/- 854 for grade 0 (no otosclerosis, n = 711), 1896 +/- 317 for grade 1 (inactive otosclerosis, n = 109), and 1632 +/- 255 for grades 2 and 3 combined (mixed/active otosclerosis, n 35). There was a strong inverse correlation of CT density to histologic grade at ROIs Nos. 1-5 (ANOVA, p < 0.0001). The inter-rater reliability for CT density was very good (correlation coefficient 0.87, p < 0.05). ROC curves suggested a cut-off of 2,150HU to distinguish otosclerosis from normal bone, and 1,811HU to distinguish low grade from mixed/high grade otosclerosis. Conclusions In human temporal bone specimens, CT density may be used to distinguish normal bone from bone involved by otosclerosis. A higher histologic grade (i.e., indicating a more active otosclerotic focus) correlated with lower density.
引用
收藏
页码:E605 / E612
页数:8
相关论文
共 50 条
  • [1] Prevalence of histologic otosclerosis: An unbiased temporal bone study in Caucasians
    Declau, F.
    van Spaendonck, M.
    Timmermans, J. P.
    Michaels, L.
    Liang, J.
    Qiu, J. P.
    van de Heyning, P.
    Otosclerosis and Stapes Surgery, 2007, 65 : 6 - 16
  • [2] Temporal Bone High Resolution Computed Tomography Findings in a Case of Postpartum Otosclerosis
    Parillo, Marco
    Bitonti, Maria Teresa
    Vaccarino, Federica
    Zobel, Bruno Beomonte
    Mallio, Carlo Augusto
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2024, 76 (01) : 1130 - 1133
  • [3] Temporal Bone High Resolution Computed Tomography Findings in a Case of Postpartum Otosclerosis
    Marco Parillo
    Maria Teresa Bitonti
    Federica Vaccarino
    Bruno Beomonte Zobel
    Carlo Augusto Mallio
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2024, 76 : 1130 - 1133
  • [4] Bone Density Development of the Temporal Bone Assessed by Computed Tomography
    Takahashi, Kuniyuki
    Morita, Yuka
    Ohshima, Shinsuke
    Izumi, Shuji
    Kubota, Yamato
    Horii, Arata
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : 1445 - 1449
  • [5] Automated detection of otosclerosis with interpretable deep learning using temporal bone computed tomography images
    Wang, Zheng
    Song, Jian
    Lin, Kaibin
    Hong, Wei
    Mao, Shuang
    Wu, Xuewen
    Zhang, Jianglin
    HELIYON, 2024, 10 (08)
  • [6] HISTOLOGIC STUDY OF PERFUSED HUMAN TEMPORAL BONE
    RUTLEDGE, LJ
    LARYNGOSCOPE, 1969, 79 (12): : 2104 - &
  • [7] Otosclerosis: Incidence of positive findings on temporal bone computed tomography (TBCT) and audiometric correlation in Korean patients
    Min, Jin-Young
    Chung, Won-Ho
    Lee, Woo Young
    Cho, Yang Sun
    Hong, Sung Hwa
    Kim, Hyoung Jin
    Lee, Hyun-Seok
    AURIS NASUS LARYNX, 2010, 37 (01) : 23 - 28
  • [8] Value of temporal bone density measurements in otosclerosis patients with normal-appearing computed tomographic scan
    Tringali, Stephane
    Pouget, Jean-Francois
    Bertholon, Pierre
    Dubreuil, Christian
    Martin, Christian
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2007, 116 (03): : 195 - 198
  • [9] The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant Site: Micro-Computed Tomography and Histologic Analysis
    Suttapreyasri, Srisurang
    Suapear, Pradipat
    Leepong, Narit
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2026 - 2031
  • [10] Bone density in human dentate and edentulous mandibles using computed tomography
    Bassi, F
    Procchio, M
    Fava, C
    Schierano, G
    Preti, G
    CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (05) : 356 - 361