Study on Calculation Model for Compressive Strength of Water Saturated Recycled Aggregate Concrete

被引:7
作者
Ge, Pei [1 ]
Huang, Wei [1 ]
Zhang, Hao [1 ]
Quan, Wenli [1 ]
Guo, Yuting [1 ]
机构
[1] Xian Univ Architecture & Technol, Coll Civil Engn, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Recycled aggregate concrete; Water saturation; Mix proportion design; Compressive strength; Calculation model; FLY-ASH; MECHANICAL-PROPERTIES; DYNAMIC-BEHAVIOR;
D O I
10.1007/s12205-021-0286-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been proved that the compressive strength of water saturated concrete is lower than that of air dry concrete. Due to the water absorption of recycled aggregate (RA) is noticeably higher than that of natural aggregate (NA), the mechanical properties of water saturated recycled aggregate concrete (RAC) are quite different from those of water saturated natural aggregate concrete (NAC). At the same time, the calculation of concrete compressive strength is the first step of concrete mix proportion design. Therefore, it is essential to investigate the compressive strength of RAC in water saturated state. In this study, firstly, the water content and effective water absorption of NA, recycled brick aggregate (RBA) and recycled concrete aggregate (RCA), as well as the water content and effective water absorption of concrete specimen were tested; secondly, the effects of water/cement ratio, water saturation and coarse aggregate types on the compressive strength of water saturated concrete were studied; finally, the calculation model for compressive strength of water saturated concrete was proposed. The test results show that: Within 120 hours, the maximum effective water absorption of NA, RCA and RBA is 0.32%, 0.61% and 8.18%, respectively. Within 240 hour, the maximum effective water absorption of NAC, recycled concrete aggregate concrete (RCAC) and recycled brick aggregate concrete (RBAC) is 0.73%, 0.81% and 1.89%, respectively. In air dry and water saturated state, the descending order of compressive strength of concrete is: NAC > RCAC > RBAC. The average relative error of the calculation model for compressive strength of water saturated concrete is 7.1%. In the calculation model, water/cement ratio, effective water absorption, water saturation and coarse aggregate types are considered. The results of this study have great significance for the mix proportion design of water saturated concrete.
引用
收藏
页码:273 / 285
页数:13
相关论文
共 46 条
[1]  
[Anonymous], 2017, C330C330M17 ASTM INT
[2]  
[Anonymous], 2018, C39C39M18 ASTM INT
[3]  
[Anonymous], 1990, 8121101990 BS
[4]  
[Anonymous], 2007, ASTM C29/C29M-07
[5]  
[Anonymous], 2014, Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
[6]  
[Anonymous], 1991, ACI, 211.1-91: Standard practice for selecting proportions for normal, heavyweight, and mass concrete
[7]  
[Anonymous], 1998, 211298 ACI
[8]   Cementing Efficiency of Flash and Rotary-Calcined Metakaolin in Concrete [J].
Ashish, Deepankar Kumar ;
Verma, Surender Kumar .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2019, 31 (12)
[9]  
ASTM, 2015, C12715 ASTM ASTM INT
[10]   Internal Curing Effect and Compressive Strength Calculation of Recycled Clay Brick Aggregate Concrete [J].
Chen, Feng ;
Wu, Kai ;
Ren, Lijian ;
Xu, Jianan ;
Zheng, Huiming .
MATERIALS, 2019, 12 (11)