Predictors of functional outcome following transsyndesmotic screw fixation of ankle fractures

被引:401
作者
Weening, B
Bhandari, M
机构
[1] McMaster Univ, Med Ctr, Dept Clin Epidemiol & Biostat, Hamilton, ON L8N 3Z5, Canada
[2] McMaster Univ, Div Orthopaed Surg, Hamilton, ON, Canada
关键词
syndesmosis; ankle fracture; functional outcomes; internal fixation; complications;
D O I
10.1097/00005131-200502000-00006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Given the continued debate regarding syndesmotic screw fixation, we reviewed our institution's series of ankle syndesmotic screw insertions: 1) to examine technical aspects of syndesmotic screw fixation; and 2) to identify predictors of function and quality of life utilizing validated instruments. Design: Retrospective observational study (level TV). Setting: Three university hospitals. Patients and Methods: All patients with ankle injuries who received syndesmotic screw fixation at 3 university-affiliated hospitals from 1998 to 2001. A combined hospital database for all 3 university affiliated hospitals was searched to identify all ankle fractures. Potentially eligible patients' charts were hand searched to determine the use of syndesmotic screw fixation. Radiographs from each patient were assessed for final eligibility for study inclusion. Baseline demographic information, fracture type (Lauge-Hansen, AO Weber), radiographic measurements of syndesmotic reduction, type of implants (number of screws, number of cortices, screw size), and screw removal at follow-up were determined. All radiographs were standardized for magnification. Patients also reported return to work, a visual analogue ankle pain score, and completed 2 functional outcomes instruments (Short Musculoskeletal Functional Assessment Index, Olerud and Molander Scale). Main Outcomes: Return to work, a visual analogue ankle pain score, and 3 functional outcomes instruments (Short Musculoskeletal Functional Assessment Index, Olerud and Molander Scale). (80%). Seventy percent of injuries were pronation external rotation injuries, and 30% were supination external rotation injuries. The ankle was dislocated in 45% of cases. The most common constructs for fixation included lateral plates with syndesmotic screws (45%). The majority of constructs included a single 3.5-mm cortical screw through 3 cortices of bone. Based upon postoperative x-rays, 16% of syndesmoses were not reduced. Additionally, 8 patients were deemed have inappropriate/lack of indications for syndesmotic screw insertion. At final follow-up (N = 39 patients, mean 18.1 months), patients achieved good function and quality of life (mean scores: Short Musculoskeletal Functional Assessment functional index = 11.4 +/- 10.6, Short Musculoskeletal Functional Assessment bother index = 13.5 +/- 13.1, Olerud and Molander = 74.1 +/- 23.4, visual analogue pain scale = 1.7 +/- 1.9). The only significant predictor of functional outcome was reduction of the syndesmosis (P = 0.04). This variable alone accounted for 18% of the variation in Short Musculoskeletal Functional Assessment Index physical function scores and 15% of the variance in the Olerud and Molander (running subscale) outcome measure. Conclusions/Signifleance: Our findings suggest: 1) technical aspects of syndesmotic screw fixation vary between surgeons; 2) 16% of syndesmotic screws may have been unnecessary; and 3) despite variability in technique and indications, anatomic reduction of syndesmosis was significantly associated with improved Short Musculoskeletal Functional Assessment Index functional outcome. Larger, prospective studies are needed to further explore our findings.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 31 条
[1]   CONTROVERSIES IN DIAGNOSIS AND MANAGEMENT OF SYNDESMOSIS INJURIES OF THE ANKLE [J].
AMENDOLA, A .
FOOT & ANKLE, 1992, 13 (01) :44-50
[2]   MECHANICAL CONSIDERATIONS FOR THE SYNDESMOSIS SCREW - A CADAVER STUDY [J].
BODEN, SD ;
LABROPOULOS, PA ;
MCCOWIN, P ;
LESTINI, WF ;
HURWITZ, SR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (10) :1548-1555
[3]   TIBIOTALAR JOINT DYNAMICS - INDICATIONS FOR THE SYNDESMOTIC SCREW - A CADAVER STUDY [J].
BURNS, WC ;
PRAKASH, K ;
ADELAAR, R ;
BEAUDOIN, A ;
KRAUSE, W .
FOOT & ANKLE, 1993, 14 (03) :153-158
[4]  
CHISSELL HR, 1995, J BONE JOINT SURG BR, V77B, P435
[5]   Ankle fractures and syndesmosis injuries [J].
Donatto, KC .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (01) :79-+
[6]   Syndesmotic disruption in low fibular fractures associated with deltoid ligament injury [J].
Ebraheim, NA ;
Elgafy, H ;
Padanilam, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (409) :260-267
[7]   Musculoskeletal function assessment instrument: Criterion and construct validity [J].
Engelberg, R ;
Martin, DP ;
Agel, J ;
Obremsky, W ;
Coronado, G ;
Swiontkowski, MF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (02) :182-192
[8]   Musculoskeletal function assessment: Reference values for patient and non-patient samples [J].
Engelberg, R ;
Martin, DP ;
Agel, J ;
Swiontkowski, MF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (01) :101-108
[9]   Early complications of surgically managed ankle fractures related to the AO classification - A review of 118 ankle fractures treated with open reduction and internal fixation [J].
Hoiness, P ;
Stromsoe, K .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (5-6) :276-279
[10]  
Inman V. T., 1976, The joints of the ankle