Selective determination of ammonium ions by high-speed ion-exclusion chromatography on a weakly basic anion-exchange resin column

被引:30
|
作者
Mori, M
Tanaka, K
Helaleh, MIH
Xu, Q
Ikedo, M
Ogura, Y
Sato, S
Hu, WZ
Hasebe, K
机构
[1] Natl Inst & Adv Ind Sci & Technol Seto, Aichi 4890884, Japan
[2] Chubu Univ, Natl Inst Adv Ind Sci & Technol Seto, Aichi 4890884, Japan
[3] Chubu Univ, Grad Sch Engn, Aichi 4890884, Japan
[4] Tosoh Corp, Yamaguchi 7468501, Japan
[5] Hokkaido Univ, Kita Ku, Sapporo, Hokkaido 0608010, Japan
关键词
water analysis; environmental analysis; ammonium ions; inorganic cations; tetrabutylammonium hydroxide;
D O I
10.1016/S0021-9673(03)00625-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes an ion-exclusion chromatographic system for the rapid and selective determination of ammonium ion. The optimized ion-exclusion chromatographic system was established with a polymethacrylate-based weakly basic anion-exchange resin column (TSKgel DEAE-5PW) as the separation column, an aqueous solution containing 0.05 mM tetramethylammonium hydroxide (pH 9.10) as eluent with conductimetric detection for the analyte determination. Under the optimum chromatographic conditions, ammonium ion was determined within 2.3 min with a detection limit (S/N = 3) better than 0.125 muM. Ammonium ion in rain and river waters was precisely determined using this ion-exclusion chromatographic system. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 7 条
  • [1] High-speed simultaneous ion-exclusion/cation-exchange chromatography of anions and cations on a weakly acidic cation-exchange resin column
    Mori, M
    Tanaka, K
    Helaleh, MIH
    Xu, Q
    Ikedo, M
    Ogura, Y
    Sato, S
    Hu, WZ
    Hasebe, K
    Haddad, PR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 219 - 224
  • [2] High-speed ion-exclusion chromatography of dissolved carbon dioxide on a small weakly acidic cation-exchange resin column with ion-exchange enhancement columns of conductivity detection
    Mori, M
    Ikedo, M
    Hu, WZ
    Helaleh, MIH
    Xu, Q
    Itabashi, H
    Tanaka, K
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1092 (02) : 250 - 253
  • [3] High-performance ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin
    Tanaka, K
    Ohta, K
    Haddad, PR
    Fritz, JS
    Miyanaga, A
    Hu, WZ
    Hasebe, K
    Lee, KP
    Sarzanini, C
    JOURNAL OF CHROMATOGRAPHY A, 2001, 920 (1-2) : 239 - 245
  • [4] Determination of some aliphatic carboxylic acids in anaerobic digestion process waters by ion-exclusion chromatography with conductimetric detection on a weakly acidic cation-exchange resin column
    Ito, K
    Takayama, Y
    Ikedo, M
    Mori, M
    Taoda, H
    Xu, Q
    Hu, WZ
    Sunahara, H
    Hayashi, T
    Sato, S
    Hirokawa, T
    Tanaka, K
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1039 (1-2) : 141 - 145
  • [5] Simultaneous ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin by elution with sulfosalicylic acid
    Tanaka, K
    Ohta, K
    Haddad, PR
    Fritz, JS
    Miyanaga, A
    Hu, WZ
    Hasebe, K
    JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) : 167 - 174
  • [6] Ion-exclusion chromatography with the direct UV detection of non-absorbing inorganic cations using an anion-exchange conversion column in the iodide-form
    Mori, Masanobu
    Itabashi, Hideyuki
    Ikedo, Mikaru
    Tanaka, Kazuhiko
    TALANTA, 2006, 70 (01) : 174 - 177
  • [7] Determination of inorganic cations and ammonium in environmental waters by ion chromatography with a high-capacity cation-exchange column
    Thomas, DH
    Rey, M
    Jackson, PE
    JOURNAL OF CHROMATOGRAPHY A, 2002, 956 (1-2) : 181 - 186