Bismuth Microelectrode Array for Adsorptive Stripping Voltammetry to Detect Lead and Cadmium in Beverage

被引:8
作者
Liu De-Meng [1 ,2 ]
Jin Yan [1 ,2 ]
Jin Qing-Hui [1 ]
Zhao Jian-Long [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
关键词
Bismuth array; Lead; Cadmium; Adsorptive stripping voltammetry; HEAVY-METAL ANALYSIS; ELECTRODES; CARBON; IONS; FILM;
D O I
10.3724/SP.J.1096.2011.01748
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A heavy metal sensor fabricated by microelectronic mechanical system (MEMS) technology was described in this study. The sensor is three-electronic system which consisted of Bi microelectronic array working electrode, Pt counter electrode and Ag/AgCl reference electrode. Bi is low-toxic heavy metal, so the using of Bi as reaction substances can make detection process more safely. Microarray electrode takes many advantages, such as high-throughput, miniaturization and anti-interference. The experiment result shows that the sensor has a good performance in simultaneously detecting Pb2+, Cd2+. The detection limits of these two metals are 0.067 mg/L (Pb) and 0.064 mg/L (Cd) respectively with good repeatability. The sensor has been applied to detect Pb2+ (0.1 mg/L) and Cd2+ (0.025 mg/L) in Orange juice with satisfactory results.
引用
收藏
页码:1748 / 1752
页数:5
相关论文
共 13 条
[1]   Anodic stripping voltammetry at in situ bismuth-plated carbon and gold microdisc electrodes in variable electrolyte content unstirred solutions [J].
Baldrianova, L. ;
Svancara, I. ;
Economou, A. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2006, 580 (01) :24-31
[2]   Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis [J].
Choi, JY ;
Seo, K ;
Cho, SR ;
Oh, JR ;
Kahng, SH ;
Park, J .
ANALYTICA CHIMICA ACTA, 2001, 443 (02) :241-247
[3]  
Gong WL, 2008, CHINESE J ANAL CHEM, V36, P177
[4]  
Karel Stulik., 2000, Pure Appl. Chem, V72, P1483
[5]   Novel disposable bismuth-sputtered electrodes for the determination of trace metals by stripping voltammetry [J].
Kokkinos, Christos ;
Economou, Anastasios ;
Raptis, Loannis ;
Efstathiou, Constantinos E. ;
Speliotis, Thanasis .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (12) :2795-2800
[6]  
Li JP, 2002, CHINESE J ANAL CHEM, V30, P1092
[7]   Heavy metal analysis of rainwaters: A comparison of TXRF and ASV analytical capabilities [J].
Montero Alvarez, A. ;
Estevez Alvarez, J. R. ;
Padilla Alvarez, R. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (02) :427-433
[8]   Microfabricated electrochemical analysis system for heavy metal detection [J].
Reay, RJ ;
Flannery, AF ;
Storment, CW ;
Kounaves, SP ;
Kovacs, GTA .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :450-455
[9]   Bismuth-coated diamond-like carbon microelectrodes for heavy metals determination [J].
Rehacek, Vlastimil ;
Hotovy, Ivan ;
Vojs, Marian .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :193-197
[10]   Detection of heavy metal ions in water by high-resolution surface plasmon resonance spectroscopy combined with anodic stripping voltammetry [J].
Wang, Shaopeng ;
Forzani, Erica S. ;
Tao, Nongjian .
ANALYTICAL CHEMISTRY, 2007, 79 (12) :4427-4432