Development and in vitro validation of a simplified numerical model for the design of a biomimetic femoral stem

被引:43
作者
Jette, Bruno [1 ]
Brailovski, Vladimir [1 ]
Simoneau, Charles [1 ]
Dumas, Mathieu [1 ]
Terriault, Patrick [1 ]
机构
[1] Ecole Technol Super, Dept Mech Engn, 1100 None Dame St West, Montreal, PQ H3C 1K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Diamond cubic lattice structure; Laser powder-bed fusion; Finite element analysis; Digital image correlation; Biomimetic femoral stem; Hip prosthesis; FINITE-ELEMENT-ANALYSIS; MECHANICAL-PROPERTIES; STRAIN DISTRIBUTION; PROXIMAL FEMUR; STRUCTURAL-PROPERTIES; BONE-RESORPTION; HIP-REPLACEMENT; WOLFFS LAW; COMPOSITE; COMPONENTS;
D O I
10.1016/j.jmbbm.2017.10.019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Dense and stiff metallic femoral stems implanted into femurs for total hip arthroplasties produce a stress shielding effect since they modify the original load sharing path in the bony structure. Consequently, in the long term, the strain adaptive nature of bones leads to bone resorption, implant loosening, and the need for arthroplasty revision. The design of new cementless femoral stems integrating open porous structures can reduce the global stiffness of the stems, allowing them a better match with that of bones and provide their firm fixation via bone ingrowth, and, thus reduce the risk of implantation failure. Methods: This paper aims to develop and validate a simplified numerical model of stress shielding, which calculates the levels of bone resorption or formation by comparing strain distributions on the surface of the intact and the implanted femurs subjected to a simulated biological loading. Two femoral stems produced by laser powder-bed fusion using Ti-6Al-4V alloy are employed: the first is fully dense, while the second features a diamond cubic lattice structure in its core. The validation consists of a comparison of the numerically calculated force-displacement diagrams, and displacement and strain fields with their experimental equivalents obtained using the digital image correlation technique. Results and conclusions: The numerical models showed reasonable agreement between the force-displacement diagrams. Also, satisfactory results for the correlation analyses of the total displacement and equivalent strain fields were obtained. The stress shielding effect of the implant was assessed by comparing the equivalent strain fields of the implanted and intact femurs. The results obtained predicted less bone resorption in the femur implanted with the porous stem than with its dense counterpart.
引用
收藏
页码:539 / 550
页数:12
相关论文
共 77 条
  • [1] Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis
    Anguiano-Sanchez, Jesica
    Martinez-Romero, Oscar
    Siller, Hector R.
    Diaz-Elizondo, Jose A.
    Flores-Villalba, Eduardo
    Rodriguez, Ciro A.
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [2] [Anonymous], 2007, Med. Sci, DOI [10.3923/jms.2007.460.467, DOI 10.3923/JMS.2007.460.467]
  • [3] [Anonymous], 2010, 72064 ISO
  • [4] High-strength porous biomaterials for bone replacement: A strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints
    Arabnejad, Sajad
    Johnston, R. Burnett
    Pura, Jenny Ann
    Singh, Baljinder
    Tanzer, Michael
    Pasini, Damiano
    [J]. ACTA BIOMATERIALIA, 2016, 30 : 345 - 356
  • [5] ASME, 2012, V V 10 1 ILL CONC VE
  • [6] State of the art review on design and manufacture of hybrid biomedical materials: Hip and knee prostheses
    Bahraminasab, Marjan
    Farahmand, Farzam
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (09) : 785 - 813
  • [7] AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - THEORETICAL DEVELOPMENT
    BEAUPRE, GS
    ORR, TE
    CARTER, DR
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) : 651 - 661
  • [8] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [9] The role of parameter identification in finite element contact analyses with reference to orthopaedic biomechanics applications
    Bernakiewicz, M
    Viceconti, M
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (01) : 61 - 67
  • [10] BOBYN JD, 1990, CLIN ORTHOP RELAT R, P196