Some clinical applications of the electrochemical biosensors

被引:14
作者
Arredondo, Michelle [1 ]
Stoytcheva, Margarita [1 ]
Zlatev, Roumen [1 ]
Gochev, Velizar [2 ]
机构
[1] Univ Autonoma Baja California, Inst Ingn, Mexicali 21280, Baja California, Mexico
[2] Paisij Hilendarski Univ Plovdiv, Dept Biochem & Microbiol, BG-4000 Plovdiv, Bulgaria
关键词
Biosensors; clinical analysis; cholinesterases; glucose; trypsin; AMPEROMETRIC ENZYME ELECTRODES; SERUM-CHOLINESTERASE ACTIVITY; GLUCOSE-OXIDASE; CARBON NANOTUBE; ACUTE-PANCREATITIS; IMMOBILIZED ACETYLCHOLINESTERASE; ORGANOPHOSPHORUS PESTICIDES; CARBAMATE INSECTICIDES; COMPOSITE FILM; BLOOD-GLUCOSE;
D O I
10.2174/138955712802762031
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Electrochemical biosensing, due to its sensitivity and specificity, combined with the low-cost and operation convenience of the equipment, is considered as a promising point-of-care approach in clinical analysis. This review presents the basic principles of operation, the current status, and the trends in the development and the clinical implementation of some selected electrochemical biosensors. These include: electrochemical glucose biosensors successfully applied in diabetes management, and electrochemical biosensors for cholinesterases and trypsin activities determination. The latter, although less common, demonstrate the potential of improving the existing clinical methods in the diagnostics and the treatment of neurotoxic, neurological, and pancreatic diseases.
引用
收藏
页码:1301 / 1313
页数:13
相关论文
共 185 条
[61]   Nanomaterial-based electrochemical biosensors for medical applications [J].
Kerman, Kagan ;
Saito, Masato ;
Yamamura, Shohei ;
Takamura, Yuzuru ;
Tamiya, Eiichi .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (07) :585-592
[62]   MULTIPLEXED FIBER BRAGG GRATING STRAIN-SENSOR SYSTEM WITH A FIBER FABRY-PEROT WAVELENGTH FILTER [J].
KERSEY, AD ;
BERKOFF, TA ;
MOREY, WW .
OPTICS LETTERS, 1993, 18 (16) :1370-1372
[63]   An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes [J].
Kong, Tao ;
Chen, Yang ;
Ye, Yiping ;
Zhang, Kun ;
Wang, Zhenxing ;
Wang, Xiaoping .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01) :344-350
[64]  
Kost G.J., 2002, Principles practice of point-of-care testing
[65]  
Kulys J., 1981, ANAL SYSTEMS BASIS I
[66]   ELECTRON EXCHANGE BETWEEN THE ENZYME ACTIVE-CENTER AND ORGANIC METAL [J].
KULYS, JJ ;
SAMALIUS, AS ;
SVIRMICKAS, GJS .
FEBS LETTERS, 1980, 114 (01) :7-10
[67]  
Kumar C.S.S.R., 2007, NANOMATERIALS BIOSEN
[68]   High-performance biosensors based on enzyme precipitate coating in gold nanoparticle-conjugated single-walled carbon nanotube network films [J].
Kwon, Ki Young ;
Yang, Seung Bo ;
Kong, Byung-Seon ;
Kim, Jungbae ;
Jung, Hee-Tae .
CARBON, 2010, 48 (15) :4504-4509
[69]   Procalcitonin, soluble interleukin-2 receptor, and soluble E-selectin in predicting the severity of acute pancreatitis [J].
Kylänpää-Bäck, ML ;
Takala, A ;
Kemppainen, EA ;
Puolakkainen, PA ;
Leppäniemi, AK ;
Karonen, SL ;
Orpana, A ;
Haapiainen, RK ;
Repo, H .
CRITICAL CARE MEDICINE, 2001, 29 (01) :63-69
[70]   Protein engineering and electrochemical biosensors [J].
Lambrianou, Andreas ;
Demin, Soren ;
Hall, Elizabeth A. H. .
BIOSENSING FOR THE 21ST CENTURY, 2008, 109 :65-96