Acoustic shadows detection, application to accurate reconstruction of 3D intraoperative ultrasound

被引:6
作者
Hellier, Pierre [1 ,2 ,3 ,5 ]
Coupe, Pierrick [1 ,2 ,3 ]
Meyer, Pierre [1 ,2 ,3 ]
Morandi, Xavier [1 ,2 ,3 ,4 ]
Collins, D. Louis [5 ]
机构
[1] IRISA, VisAGeS U746 Unit Project, INRIA, Campus Beaulieu, F-35042 Rennes, France
[2] IRISA, VisAGeS U746 Unit Project, INSERM, F-35042 Rennes, France
[3] Univ Rennes 1, CNRS, F-35042 Rennes, France
[4] Univ Rennes 1, Ctr Hosp Regional, Serv Neurochirurgie, F-35042 Rennes, France
[5] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2T5, Canada
来源
2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4 | 2008年
关键词
biomedical image processing; biomedical acoustics; image restoration;
D O I
10.1109/ISBI.2008.4541310
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Acoustic shadows appear in ultrasound images as regions of low signal intensity after boundaries with very high acoustic impedance differences. Acoustic shadows can be viewed as informative features to detect lesions or calcifications, or can be considered as damageable artifacts for image processing tasks such as segmentation, registration or 3D reconstruction. In both cases, the detection of these acoustic shadows is useful. This paper proposes a new geometrical method to detect these shadows based on statistical analysis of intensity profiles along the lines that compose the B-scan image. The results demonstrate that this detection improves the accuracy of 3D reconstruction of intraoperative ultrasound.
引用
收藏
页码:1569 / +
页数:2
相关论文
共 11 条
[1]   Probe trajectory interpolation for 3D reconstruction of freehand ultrasound [J].
Coupe, Pierrick ;
Hellier, Pierre ;
Morandi, Xavier ;
Barillot, Christian .
MEDICAL IMAGE ANALYSIS, 2007, 11 (06) :604-615
[2]   Computerized analysis of shadowing on breast ultrasound for improved lesion detection [J].
Drukker, K ;
Giger, ML ;
Mendelson, EB .
MEDICAL PHYSICS, 2003, 30 (07) :1833-1842
[3]   A novel multiscale nonlinear thresholding method for ultrasonic speckle suppressing [J].
Hao, XH ;
Gao, SK ;
Gao, XR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :787-794
[4]   Image denoising using total least squares [J].
Hirakawa, Keigo ;
Parks, Thomas W. .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (09) :2730-2742
[5]  
KRISSIAN K, 2005, CVPR 05, P547
[6]  
Leroy A, 2004, LECT NOTES COMPUT SC, V3216, P837
[7]   AN ADAPTIVE WEIGHTED MEDIAN FILTER FOR SPECKLE SUPPRESSION IN MEDICAL ULTRASONIC IMAGES [J].
LOUPAS, T ;
MCDICKEN, WN ;
ALLAN, PL .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1989, 36 (01) :129-135
[8]  
MADABHUSI A, 2006, EMBS, P3070
[9]   Registration of freehand 3D ultrasound and magnetic resonance liver images [J].
Penney, GP ;
Blackall, JM ;
Hamady, MS ;
Sabharwal, T ;
Adam, A ;
Hawkes, DJ .
MEDICAL IMAGE ANALYSIS, 2004, 8 (01) :81-91
[10]  
Roche A, 2000, INT J IMAG SYST TECH, V11, P71, DOI 10.1002/(SICI)1098-1098(2000)11:1<71::AID-IMA8>3.0.CO