OUTCOMES OF MANAGEMENT OF MID-SHAFT CLAVICLE FRACTURES IN SAUDI ARABIA

被引:0
作者
Alqahtani, Mohammed Saeed [1 ]
Alsalaiman, Zyad Musaad [1 ]
Almejrad, Fahad Abdulmohsen [1 ]
Alqarni, Moayad Abdullah [1 ]
Al Sirhani, Meshari Ushabab [1 ]
机构
[1] Almaarefa Univ, Riyadh, Saudi Arabia
来源
INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES | 2019年 / 6卷 / 01期
关键词
Clavicle; Mid-shaft; Fracture; Open reduction internal fixation; Complications; PLATE FIXATION; EPIDEMIOLOGY;
D O I
10.5281/zenodo.2541095
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background: Open reduction and internal fixation (ORIF) using plate osteosynthesis for midshaft clavicle fractures is often complicated by the prominence of the implant due to the subcutaneous position of the clavicle. Reoperation rates for symptomatic clavicle plate removal have been reported to be as high as 53%. We sought to determine to which degree do clinical outcomes (all cause reoperation rate and rate of fracture union) differ between types of clavicle plates. Materials and methods: A retrospective chart review was performed in Riyadh, Saudi Arabia hospitals database for patients treated with ORIF for mid-shaft clavicle fractures (OTA/AO type 15-B). Implants included in this review were 2.7 mm reconstruction plates, 3.5 mm reconstruction plates, 3.5 mm precontoured clavicle plates and 3.5 mm locking compression plates. The primary outcome measure was the all cause reoperation rate. Secondary outcomes compared he rate fracture union, documented infection, hardware failures and clinical symptoms at the surgical site among the various plate types. Data was collected and descriptive statistics were analyzed. p values < 0.05 were considered statistically significant. Results: A total of 102 midshaft clavicle fractures treated with ORIF were included in this study. The majority of patients were <= 50 years old (83.3%) and male (72.5%). The overall union rate for all plating constructs was 97.1%. We found that age, sex and smoking were not associated with the rate of re-operation. In addition, the fracture classification, type of implant used and number of screws used didn't increase the risk of revision surgery. In addition, more than 50% of patients complaining of pain at 6 weeks post-operatively required a second surgery for removal of hardware. Moreover, there was no association between age, sex, smoking, fracture classification or plate type and the rate of union. Interestingly, clavicle fractures fixed with 3.5 mm reconstruction plates were more likely to have hardware failure due to plastic deformation, whereas 2.7 mm plates were more likely to fail by plate breakage. Conclusion: Although different types of implants have different biomechanical properties, no difference in reoperation, union and plate removal rates were found between the various plate types. Future studies with a larger sample size are required to further examine these outcomes.
引用
收藏
页码:1122 / 1130
页数:9
相关论文
共 50 条
  • [21] Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review
    Houwert, R. Marijn
    Wijdicks, Frans-Jasper
    Bisschop, Charlotte Steins
    Verleisdonk, Egbert-Jan
    Kruyt, Moyo
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) : 579 - 585
  • [22] Effects of Internal Fixation for Mid-Shaft Clavicle Fractures on Shoulder Kinematics During Humeral Elevations
    Hung, Li-Wei
    Lu, Hsuan-Yu
    Chang, Chung-Hsun
    Chen, Tsan-Yang
    Wang, Ting-Ming
    Lu, Tung-Wu
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [23] Comparison of plate osteosynthesis versus non-operative management for mid-shaft clavicle fractures-A prospective study
    Bhardwaj, Akshay
    Sharma, Gaurav
    Patil, Ashok
    Rahate, Vaijnath
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (06): : 1104 - 1107
  • [24] Residual kinematic deviations of the shoulder during humeral elevation after conservative treatment for mid-shaft clavicle fractures
    Hung, Li-Wei
    Lu, Hsuan-Yu
    Chen, Tsan-Yang
    Wang, Ting-Ming
    Lu, Tung-Wu
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [25] Stability of mid-shaft clavicle fractures after plate fixation versus intramedullary repair and after hardware removal
    Sean D. Smith
    Coen A. Wijdicks
    Kyle S. Jansson
    Robert E. Boykin
    Frank Martetschlaeger
    Peter-Paul de Meijer
    Peter J. Millett
    Tom R. Hackett
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 448 - 455
  • [26] Displaced mid-shaft clavicular fractures: state of the art for athletes and young active people
    Saragaglia, Dominique
    Refaie, Ramsay
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (10) : 2679 - 2686
  • [27] Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review
    R. Marijn Houwert
    Frans-Jasper Wijdicks
    Charlotte Steins Bisschop
    Egbert-Jan Verleisdonk
    Moyo Kruyt
    International Orthopaedics, 2012, 36 : 579 - 585
  • [28] Functional Results Following Titanium Elastic-Stable Intramedullary Nailing (ESIN) of Mid-Shaft Clavicle Fractures
    Braun, K. F.
    Siebenlist, S.
    Sandmann, G. H.
    Martetschlaeger, F.
    Kraus, T.
    Schroedl, C.
    Kirchhoff, C.
    Neumaier, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2014, 81 (02) : 118 - 121
  • [29] Management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis
    Yanbin Zhu
    Ye Tian
    Tianhua Dong
    Wei Chen
    Fei Zhang
    Yingze Zhang
    International Orthopaedics, 2015, 39 : 319 - 328
  • [30] Comparison of plate fixation vs. intramedullary fixation for the management of mid-shaft clavicle fractures: A systematic review and meta-analysis of randomised controlled trials
    Ju, Weina
    Mohamed, Sayid Omar
    Qi, Baochang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (03) : 2783 - 2793