Semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma stage III/IV-A feasibility study

被引:63
作者
Fabel, M. [1 ,2 ]
von Tengg-Kobligk, H. [1 ]
Giesel, F. L. [1 ]
Bornemann, L. [3 ]
Dicken, V. [3 ]
Kopp-Schneider, A. [5 ]
Moser, C. [4 ]
Delorme, S. [1 ]
Kauczor, H. -U. [1 ]
机构
[1] German Canc Res Ctr, Dept Oncol Diagnost & Therapy, D-69120 Heidelberg, Germany
[2] Univ Hosp Schleswig Holstein, Dept Radiol, D-24105 Kiel, Germany
[3] MeVis Res GmbH, Bremen, Germany
[4] Univ Heidelberg Hosp, Dept Dermatol, Heidelberg, Germany
[5] German Canc Res Ctr, Dept Biostat, D-69120 Heidelberg, Germany
关键词
lymph nodes; RECIST; therapy monitoring; volumetric analysis; malignant melanoma;
D O I
10.1007/s00330-008-0866-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Therapy monitoring in oncological patient care requires accurate and reliable imaging and post-processing methods. RECIST criteria are the current standard, with inherent disadvantages. The aim of this study was to investigate the feasibility of semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma compared to manual volumetric analysis and RECIST. Multislice CT was performed in 47 patients, covering the chest, abdomen and pelvis. In total, 227 suspicious, enlarged lymph nodes were evaluated retrospectively by two radiologists regarding diameters (RECIST), manually measured volume by placement of ROIs and semi-automated volumetric analysis. Volume (ml), quality of segmentation (++/-) and time effort (s) were evaluated in the study. The semi-automated volumetric analysis software tool was rated acceptable to excellent in 81% of all cases (reader 1) and 79% (reader 2). Median time for the entire segmentation process and necessary corrections was shorter with the semi-automated software than by manual segmentation. Bland-Altman plots showed a significantly lower interobserver variability for semi-automated volumetric than for RECIST measurements. The study demonstrated feasibility of volumetric analysis of lymph node metastases. The software allows a fast and robust segmentation in up to 80% of all cases. Ease of use and time needed are acceptable for application in the clinical routine. Variability and interuser bias were reduced to about one third of the values found for RECIST measurements.
引用
收藏
页码:1114 / 1122
页数:9
相关论文
共 20 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs
    Bolte, H
    Riedel, C
    Jahnke, T
    Inan, N
    Freitag, S
    Kohl, G
    Heller, M
    Biederer, J
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (01) : 28 - 35
  • [3] Informatics in radiology (infoRAD) -: New tools for computer assistance in thoracic CT -: Part 2.: Therapy monitoring of pulmonary metastases
    Bornemann, L
    Kuhnigk, JM
    Dicken, V
    Zidowitz, S
    Kuemmerlen, B
    Krass, S
    Peitgen, HO
    Wein, BB
    Schubert, H
    Shin, HO
    Wormanns, D
    [J]. RADIOGRAPHICS, 2005, 25 (03) : 841 - 848
  • [4] OncoTREAT: a software assistant for cancer therapy monitoring
    Bornemann, Lars
    Dicken, Volker
    Kuhnigk, Jan-Martin
    Wormanns, Dag
    Shin, Hoen-Oh
    Bauknecht, Hans-Christian
    Diehl, Volker
    Fabel, Michael
    Meier, Stefan
    Kress, Oliver
    Krass, Stefan
    Peitgen, Heinz-Otto
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 1 (05) : 231 - 242
  • [5] Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    Erasmus, JJ
    Gladish, GW
    Broemeling, L
    Sabloff, BS
    Truong, MT
    Herbst, RS
    Munden, RF
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (13) : 2574 - 2582
  • [6] Clinical cancer advances 2005: Major research advances in cancer treatment, prevention, and screening - A report from the American Society of Clinical Oncology
    Herbst, RS
    Bajorin, DF
    Bleiberg, H
    Blum, D
    Hao, D
    Johnson, BE
    Ozols, RF
    Demetri, GD
    Ganz, PA
    Kris, MG
    Levin, B
    Markman, M
    Raghavan, D
    Reaman, GH
    Sawaya, R
    Schuchter, LM
    Sweetenham, JW
    Vahdat, LT
    Vokes, EE
    Winn, RJ
    Mayer, RJ
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (01) : 190 - 205
  • [7] Evaluation of the response to treatment of solid tumours - a consensus statement of the International Cancer Imaging Society
    Husband, JE
    Schwartz, LH
    Spencer, J
    Ollivier, L
    King, DM
    Johnson, R
    Reznek, R
    [J]. BRITISH JOURNAL OF CANCER, 2004, 90 (12) : 2256 - 2260
  • [8] Measuring response in solid tumors: Unidimensional versus bidimensional measurement
    James, K
    Eisenhauer, E
    Christian, M
    Terenziani, M
    Vena, D
    Muldal, A
    Therasse, P
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1999, 91 (06) : 523 - 528
  • [9] Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
    Marten, K
    Auer, F
    Schmidt, S
    Kohl, G
    Rummeny, EJ
    Engelke, C
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (04) : 781 - 790
  • [10] MILLER AB, 1981, CANCER, V47, P207, DOI 10.1002/1097-0142(19810101)47:1<207::AID-CNCR2820470134>3.0.CO