Optimal phased-array combination for spectroscopy

被引:74
作者
Bydder, Mark [1 ]
Hamilton, Gavin [1 ]
Yokoo, Takeshi [1 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
spectroscopy; SVD; phased array; coils;
D O I
10.1016/j.mri.2008.01.050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method for making weighted linear combinations of the spectra acquired by a phased-array coil is described. Unlike most previous combination methods, no special reference points in the data are chosen to represent the coil weights. Instead, all the data points are used, which results in optimal signal-to-noise ratio more reliable estimation. The method uses singular value decomposition to identify the coil weights and extract the principal component of variation in the signal. Subsequent processing of the combined signal (e.g., Fourier transform, baseline correction, phasing) may proceed as per a single coil acquisition. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:847 / 850
页数:4
相关论文
共 19 条
  • [1] Time-domain combination of MR spectroscopy data acquired using phased-array coils
    Brown, MA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1207 - 1213
  • [2] Noise reduction in multiple-echo data sets using singular value decomposition
    Bydder, Mark
    Du, Jiang
    [J]. MAGNETIC RESONANCE IMAGING, 2006, 24 (07) : 849 - 856
  • [3] THE SINGULAR-VALUE DECOMPOSITION AND LONG AND SHORT SPACES OF NOISY MATRICES
    DEMOOR, B
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1993, 41 (09) : 2826 - 2838
  • [4] The rapid and automatic combination of proton MRSI data using multi-channel coils without water suppressionl
    Dong, Zhengchao
    Peterson, Bradley
    [J]. MAGNETIC RESONANCE IMAGING, 2007, 25 (08) : 1148 - 1154
  • [5] ENGELNMULLGES G, 1996, NUMER ALGORITHMS, P166
  • [6] AN NMR PHASED-ARRAY FOR HUMAN CARDIAC P-31 SPECTROSCOPY
    HARDY, CJ
    BOTTOMLEY, PA
    ROHLING, KW
    ROEMER, PB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) : 54 - 64
  • [7] An automated algorithm for combining multivoxel MRS data acquired with phased-array coils
    Maril, N
    Lenkinski, RE
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 317 - 322
  • [8] An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes
    Prock, T
    Collins, DJ
    Dzik-Jurasz, ASK
    Leach, MO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (02) : N39 - N46
  • [9] THE NMR PHASED-ARRAY
    ROEMER, PB
    EDELSTEIN, WA
    HAYES, CE
    SOUZA, SP
    MUELLER, OM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 192 - 225
  • [10] Spectral analysis of multichannel MRS data
    Sandgren, N
    Stoica, P
    Frigo, FJ
    Selén, Y
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2005, 175 (01) : 79 - 91