Comparing the performance of mono- and biplane fluoroscopy systems in diagnostic and interventional neuroangiography using the dose-area product

被引:9
|
作者
Johnson, D [1 ]
Coley, SJ
Kyrion, J
Taylor, WJ
机构
[1] Atkinson Morleys Hosp, Dept Neuroradiol, London SW20 0NE, England
[2] UCL Natl Hosp Neurol & Neurosurg, Lysholm Radiol Dept, London WC1N 3BG, England
[3] Univ London St Georges Hosp, Radiat Protect Ctr, London NW7 0QT, England
关键词
cerebral angiography; radiation dose; interventional neuroradiology; fluoroscopy;
D O I
10.1007/s002340000512
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Biplane digital imaging systems are favoured in neurointerventional practice since they are believed to contribute to safer, quicker and more efficacious procedures. Our aim was to establish if such equipment exposes patients to the same level of ionising radiation as monoplane systems. We reviewed monoplane and biplane fluoroscopy screening times and dose-area products (DAP) for 267 diagnostic cerebral angiograms and 56 neurointerventional cases. Significantly lower DAP for the latter were recorded on the biplane equipment, demonstrating an important reduction in patient exposure to radiation. There were no significant differences between the two systems for diagnostic cerebral angiography.
引用
收藏
页码:728 / 734
页数:7
相关论文
共 6 条
  • [1] Comparing the performance of mono- and biplane fluoroscopy systems in diagnostic and interventional neuroangiography using the dose-area product
    D. Johnson
    S. J. Coley
    J. Kyrion
    W. J. Taylor
    Neuroradiology, 2001, 43 : 728 - 734
  • [2] Comparing the performance of mono-planar and bi-planar systems in neuroangiography using dose-area product
    Johnson, DR
    Kyrion, J
    Taylor, W
    RADIOLOGY, 2000, 217 : 598 - 598
  • [3] Practical In situ Calibration for Dose-area Product Meter in Interventional Fluoroscopy: Beam-area Method
    Dhaifina, Fara Farisa
    Ibrahim, Raushan Fikr Ilham
    Raharja, Hanendya Disha Randy
    Lubis, Lukmanda Evan
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 167 - 172
  • [4] A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose-area product meter
    Thwaites, JH
    Rafferty, MW
    Gray, N
    Black, J
    Stock, B
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (05): : 899 - 907
  • [5] Estimate Eye Lens Dose by Using Personal Dose Equivalent (HP (10)) and Dose-Area Product (DAP) in Interventional Procedures
    Hu, P.
    Wang, J.
    Hu, W.
    Liu, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E276 - E276
  • [6] A preliminary study to determine the diagnostic reference level using dose-area product for limited-area cone beam CT
    Endo, A.
    Katoh, T.
    Vasudeva, S. B.
    Kobayashi, I.
    Okano, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (04)