Iatrogenic vasospasm in carotid artery stent angioplasty with distal protection devices

被引:11
作者
Schirmer, Clemens M.
Hoit, Daniel A.
Malek, Adel M.
机构
[1] Tufts Univ New England Med Ctr, Cardiovasc & Endovasc Div, Dept Neurosurg, Boston, MA 02111 USA
[2] Tufts Univ, Sch Med, Boston, MA 02111 USA
关键词
carotid artery disease; dissection; intimal injury; stent placement; vasospasm;
D O I
10.3171/FOC/2008/24/2/E12
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Distal protection devices (DPDs) have decreased the risk of embolic stroke among patients with carotid artery ( CA) disease undergoing CA stent placement. The FilterWire EX is a first-generation fixed-basket DPD with a filter rigidly attached to a guidewire. Second-generation mobile-basket DPDs (RX Accunet or SpiderFX) allow movement of the filter relative to the guidewire and can thus reduce the potential for vessel irritation, vasospasm, or intimal injury during CA stent placement. Methods. Stent angioplasty was attempted in 40 CAs (37 patients) using the fixed-basket FilterWire DPD, a second-generation mobile-basket DPD, or no protection in 12, 6, and 22 arteries, respectively. Clinical presentation, angiographic details relating to the incidence of vasospasm or dissection, and clinical outcome data were recorded and analyzed. Results. Vasospasm was associated with use of the fixed-basket FilterWire device ( 8[67%] of 12 cases) compared with the bare unfiltered guidewire group (3[14%] of 22) and the second-generation mobile-basket DPD group (1[17%] of 6, p < 0.004). Secondary angioplasty was also associated with intraprocedural vasospasm. In a multivariate analysis, FilterWire use was an independent risk factor for vasospasm (p < 0.0003). Conclusions. A high incidence of vasospasm was observed following CA stent placement procedures in which the fixed-basket FilterWire EX DPD was used but not in unprotected CA stent placement or procedures in which a second-generation mobile-basket DPD was used. Although this phenomenon was self-limited in all instances, vasospasm should be considered a risk of these devices and may predispose to more serious vascular injury. Coronary artery stent placement should be performed with a second-generation mobile-basket DPD to minimize the risks of embolic complications and iatrogenic vascular injury.
引用
收藏
页数:7
相关论文
共 33 条
  • [1] Effect of the distal-balloon protection system on microembolization during carotid stenting
    Al-Mubarak, N
    Roubin, GS
    Vitek, JJ
    Iyer, SS
    New, G
    Leon, MB
    [J]. CIRCULATION, 2001, 104 (17) : 1999 - 2002
  • [2] Bosiers M, 2003, J ENDOVASC THER, V10, P695, DOI 10.1583/1545-1550(2003)010<0695:BEWFEI>2.0.CO
  • [3] 2
  • [4] Brown MM, 2001, LANCET, V357, P1729
  • [5] Complication with an embolic protection device during carotid angioplasty
    Cardaioli, P
    Giordan, M
    Panfili, M
    Chioin, R
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (02) : 234 - 236
  • [6] INTRA-CRANICAL PRESSURE DURING NITROGLYCERIN-INDUCED HYPOTENSION
    COTTRELL, JE
    GUPTA, B
    RAPPAPORT, H
    TURNDORF, H
    RANSOHOFF, J
    FLAMM, ES
    [J]. JOURNAL OF NEUROSURGERY, 1980, 53 (03) : 309 - 311
  • [7] Percutaneous transluminal angioplasty of the symptomatic atherosclerotic carotid arteries - Results, complications, and follow-up
    GilPeralta, A
    Mayol, A
    Marcos, JRG
    Gonzalez, A
    Ruano, J
    Boza, F
    Duran, F
    [J]. STROKE, 1996, 27 (12) : 2271 - 2273
  • [8] Protected carotid stenting in high-surgical-risk patients: The ARCHeR results
    Gray, William A.
    Hopkins, L. Nelson
    Yadav, Sanjay
    Davis, Thomas
    Wholey, Mark
    Atkinson, Richard
    Cremonesi, Alberto
    Fairman, Ronald
    Walker, Gary
    Verta, Patrick
    Popma, Jeff
    Virmani, Renu
    Cohen, David J.
    [J]. JOURNAL OF VASCULAR SURGERY, 2006, 44 (02) : 258 - 268
  • [9] Initial multicenter experience with a novel distal protection filter during carotid artery stent implantation
    Grube, E
    Colombo, A
    Hauptmann, E
    Londero, H
    Reifart, N
    Gerckens, U
    Stone, GW
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) : 139 - 146
  • [10] Henry M, 1998, J ENDOVASC SURG, V5, P293, DOI 10.1583/1074-6218(1998)005<0293:AASOTE>2.0.CO