Experimental study of concrete-filled CHS stub columns with inner FRP tubes

被引:42
|
作者
Long, Yue-Ling [1 ,3 ]
Li, Wen-Tao [1 ]
Dai, Jian-Guo [2 ]
Gardner, Leroy [3 ]
机构
[1] Guangdong Univ Technol, Dept Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Axial compression; Composite; Concrete-filled steel tube; Ductility; Experiments; Inner FRP tube; Load bearing capacity; STEEL TUBULAR COLUMNS; STRESS-STRAIN MODEL; CONFINED CONCRETE; BOX COLUMNS; BEHAVIOR; STRENGTH; TESTS; HOLLOW; HSC;
D O I
10.1016/j.tws.2017.10.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study into the axial compressive behaviour of concrete-filled circular hollow section (CHS) steel columns with internal fibre reinforced polymer (FRP) tubes is presented in this paper. A total of 17 concrete filled steel tubular (CFST) columns were tested, 15 with an inner FRP tube and 2 with no inner tube. Complementary material tests and tests on 15 FRP-confined concrete (FCC) columns were also carried out. The varied test parameters included the concrete strength, the ratio of the diameter of the steel tube to that of the FRP tube, the diameter to wall thickness ratio of the inner FRP tube and the type (influencing principally the rupture strain) of the FRP. It was found that the presence of the inner FRP tube led to considerably improved axial compressive behaviour due to the greater levels of confinement afforded to the 'doubly-confined' inner concrete core; the load-bearing capacity was increased by between about 10% and 50% and the ductility was also enhanced. Greater benefits arose with (1) increasing diameter of the inner FRP tube due to the increased portion of the cross-section that is doubly-confined and (2) increasing wall thickness of the inner FRP tube due to the increased level of confinement afforded to the inner concrete core. The load-deflection responses of all tested specimens were reported, revealing that failure was generally gradual with no sharp loss in load-bearing capacity, implying that the embedment of the inner FRP tube within the concrete enables it to continue to provide a reasonable degree of confinement even after the initiation of fibre rupture; this is different to the sudden loss of confinement typically observed in FRP externally jacketed concrete columns.
引用
收藏
页码:606 / 621
页数:16
相关论文
共 50 条
  • [21] EXPERIMENTAL STUDY OF CONCRETE-FILLED COLD-FORMED STEEL TUBULAR COLUMNS
    Zhu, Aizhu
    Lu, Yong
    Zhu, Hongping
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 1994 - 2004
  • [22] Experimental behavior of circular concrete-filled steel tube stub columns
    Yu, Zhi-wu
    Ding, Fa-xing
    Cai, C. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (02) : 165 - 174
  • [23] Torsional Behavior of Circular Concrete-Filled FRP Tubes
    St Onge, James
    Fam, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2021, 25 (03)
  • [24] Elliptical concrete-filled FRP tubes with an embedded H-shaped steel under axial compression and cyclic lateral loading: Experimental study and modelling
    Zhang, Bing
    Peng, Yutao
    Zhang, Sumei
    Lin, Shuhong
    Zhou, Chong
    Lin, Guan
    COMPOSITE STRUCTURES, 2024, 330
  • [25] Experimental investigation on lightweight concrete-filled cold-formed elliptical hollow section stub columns
    Chan, Tak-Ming
    Huai, Yun-Mei
    Wang, Wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 434 - 444
  • [26] Geopolymer concrete-filled FRP tubes: Behavior of circular and square columns under axial compression
    Ozbakkaloglu, Togay
    Xie, Tianyu
    COMPOSITES PART B-ENGINEERING, 2016, 96 : 215 - 230
  • [27] Compressive behavior of concrete-filled FRP tubes with FRP solid waste as recycled aggregates: Experimental study and analytical modelling
    Zhang, Bing
    Sun, Jiaming
    Zhang, Sumei
    Zhou, Chong
    Fan, Zhihong
    Yan, Yunhao
    Lin, Guan
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [28] Behaviour of square concrete-filled stiffened steel tubular stub columns under axial compression
    Yuan, Fang
    Huang, Hong
    Chen, Mengcheng
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (08) : 1878 - 1894
  • [29] Experimental study on the tensile behavior of square concrete-filled steel tubes
    Zhou, Meng
    Fan, Jian-Sheng
    Tao, Mu-Xuan
    Nie, Jian-Guo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 121 : 202 - 215
  • [30] Experimental investigation of axial strength of damaged concrete-filled FRP tubes
    Taveras, Osvaldo
    Fam, Amir
    Hadhood, Abdeldayem
    Song, Bhum-Keun
    STRUCTURES, 2022, 44 : 1783 - 1796