Experimental study of concrete-filled CHS stub columns with inner FRP tubes

被引:42
|
作者
Long, Yue-Ling [1 ,3 ]
Li, Wen-Tao [1 ]
Dai, Jian-Guo [2 ]
Gardner, Leroy [3 ]
机构
[1] Guangdong Univ Technol, Dept Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Axial compression; Composite; Concrete-filled steel tube; Ductility; Experiments; Inner FRP tube; Load bearing capacity; STEEL TUBULAR COLUMNS; STRESS-STRAIN MODEL; CONFINED CONCRETE; BOX COLUMNS; BEHAVIOR; STRENGTH; TESTS; HOLLOW; HSC;
D O I
10.1016/j.tws.2017.10.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study into the axial compressive behaviour of concrete-filled circular hollow section (CHS) steel columns with internal fibre reinforced polymer (FRP) tubes is presented in this paper. A total of 17 concrete filled steel tubular (CFST) columns were tested, 15 with an inner FRP tube and 2 with no inner tube. Complementary material tests and tests on 15 FRP-confined concrete (FCC) columns were also carried out. The varied test parameters included the concrete strength, the ratio of the diameter of the steel tube to that of the FRP tube, the diameter to wall thickness ratio of the inner FRP tube and the type (influencing principally the rupture strain) of the FRP. It was found that the presence of the inner FRP tube led to considerably improved axial compressive behaviour due to the greater levels of confinement afforded to the 'doubly-confined' inner concrete core; the load-bearing capacity was increased by between about 10% and 50% and the ductility was also enhanced. Greater benefits arose with (1) increasing diameter of the inner FRP tube due to the increased portion of the cross-section that is doubly-confined and (2) increasing wall thickness of the inner FRP tube due to the increased level of confinement afforded to the inner concrete core. The load-deflection responses of all tested specimens were reported, revealing that failure was generally gradual with no sharp loss in load-bearing capacity, implying that the embedment of the inner FRP tube within the concrete enables it to continue to provide a reasonable degree of confinement even after the initiation of fibre rupture; this is different to the sudden loss of confinement typically observed in FRP externally jacketed concrete columns.
引用
收藏
页码:606 / 621
页数:16
相关论文
共 50 条
  • [1] Analytical study of concrete-filled steel tubular stub columns with double inner steel tubes
    Ayough, Pouria
    Wang, Yu-Hang
    Ibrahim, Zainah
    STEEL AND COMPOSITE STRUCTURES, 2023, 47 (05) : 645 - 661
  • [2] Experimental and numerical investigation of square concrete-filled double-skin steel stiffened tubular stub columns with CHS inner tubes under axial compression
    Huang, Wei-Feng
    Shao, Yong-Bo
    Hassanein, M. F.
    Hadzima-Nyarko, Marijana
    Radu, Dorin
    Cashell, K. A.
    THIN-WALLED STRUCTURES, 2024, 199
  • [3] EXPERIMENTAL INVESTIGATION OF CONCRETE-FILLED DOUBLE SKIN TUBULAR STUB COLUMNS WITH STAINLESS STEEL OUTER TUBES
    Wang, Fangying
    Young, Ben
    Gardner, Leroy
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [4] Comprehensive experimental database and analysis of circular concrete-filled double-skin tube stub columns: A review
    Tang, Hongyuan
    Tan, Hongfei
    Ge, Sisi
    Qin, Jieyu
    Wang, Yuzhuo
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2023, 17 (12) : 1830 - 1848
  • [5] Experimental study on concrete-filled steel tube columns with inner distributed seawater and sea sand concrete-filled fiber-reinforced polymer tubes under axial compression
    Miao, Kunting
    Wei, Yang
    Dong, Fenghui
    Zheng, Kaiqi
    Wang, Jiaqing
    COMPOSITE STRUCTURES, 2023, 320
  • [6] Theoretical model for seawater and sea sand concrete-filled circular FRP tubular stub columns under axial compression
    Li, Y. L.
    Teng, J. G.
    Zhao, X. L.
    Raman, R. K. Singh
    ENGINEERING STRUCTURES, 2018, 160 : 71 - 84
  • [7] Experimental and numerical analysis of circular concrete-filled double steel tubular stub columns with inner square hollow section
    Ci, Junchang
    Jia, Hong
    Ahmed, Mizan
    Chen, Shicai
    Zhou, Daxing
    Hou, Liqun
    ENGINEERING STRUCTURES, 2021, 227
  • [8] Experimental study of clay concrete filled steel tubular stub columns under axial compression
    Ren, Qing-Xin
    Zhou, Kan
    Li, Wei
    STRUCTURES, 2024, 70
  • [9] Compressive performance of concrete-filled steel tube columns with in-built seawater and sea sand concrete-filled FRP tubes
    Wei, Yang
    Zhu, Chao
    Miao, Kunting
    Zheng, Kaiqi
    Tang, Yu
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 317
  • [10] Axial compressive behaviour of circular concrete-filled steel tubular stub columns with an inner bamboo culm
    Gan, Dan
    Li, Zexiang
    Zhang, Tao
    Zhou, Xuhong
    Chung, Kwok-fai
    STRUCTURES, 2020, 26 : 156 - 168