Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR

被引:66
作者
de Graaf, Wolter L. [1 ,2 ]
Zwanenburg, Jaco J. M. [3 ,4 ]
Visser, Fredy [3 ,4 ,8 ]
Wattjes, Mike P. [2 ]
Pouwels, Petra J. W. [3 ,5 ]
Geurts, Jeroen J. G. [6 ]
Polman, Chris H. [7 ]
Barkhof, Frederik [2 ]
Luijten, Peter R. [4 ]
Castelijns, Jonas A. [2 ]
机构
[1] Vrije Univ Amsterdam, Dept Radiol, Med Ctr Amsterdam, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Radiol, Med Ctr Amsterdam, NL-1081 HV Amsterdam, Netherlands
[3] Univ Med Ctr Utrecht, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[5] Vrije Univ Amsterdam, Dept Phys & Med Technol, Med Ctr Amsterdam, NL-1081 HV Amsterdam, Netherlands
[6] Vrije Univ Amsterdam, Dept Anat & Neurosci, Med Ctr Amsterdam, NL-1081 HV Amsterdam, Netherlands
[7] Vrije Univ Amsterdam, Dept Neurol, Med Ctr Amsterdam, NL-1081 HV Amsterdam, Netherlands
[8] Philips Healthcare, Best, Netherlands
关键词
Magnetic Resonance Imaging/methods; Imaging; Three-Dimensional; Multiple Sclerosis/diagnosis; Multiple Sclerosis/pathology; Cerebral Cortex/pathology; HIGH-FIELD MRI; HUMAN BRAIN; FLUID; HETEROGENEITY; DIAGNOSIS; 3T;
D O I
10.1007/s00330-011-2242-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To examine the feasibility and value of 7 T 3D T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) and Double Inversion Recovery (DIR) MR sequences for lesion detection in multiple sclerosis (MS). High-resolution 3D-FLAIR and 3D-DIR MR sequences at 7 T were obtained using magnetisation preparation (MP), and compared with 2D-T2-weighted and 3D-T1-weighted sequences in 10 MS patients and five healthy controls. We determined contrast ratios and counted lesions according to anatomical location. MR imaging at 7 T was safe and allowed multi-contrast imaging within clinically acceptable imaging times. Lesion to white matter (WM) and grey matter (GM) contrast ratios were higher in 3D-MP-FLAIR and 3D-MP-DIR compared with 2D-T2 and 3D-T1. Cortical (mixed+intra-cortical) and total lesion counts were 97/592 on 3D-MP-FLAIR and 100/558 on 3D-MP-DIR compared with 84/384 on 2D-T2 and 42/442 on 3D-T1. More juxta-cortical lesions were seen with 3D-MP-FLAIR (205) and 3D-MP-DIR (133) than with 2D-T2 (125) and 3D-T1 (70). Finally, higher numbers of lesions were found for deep WM lesions: 176 for 3D-MP-FLAIR and 196 for 3D-MP-DIR vs. 155 for 2D-T2 and 131 for 3D-T1. Near isotropic 3D-MP-FLAIR and 3D-MP-DIR allows high quality T2-weighted MR imaging in MS at 7 T, improving (cortical) lesion detection. Key Points aEuro cent Magnetization prepared 3D-FLAIR and 3D-DIR 7 T MRI provide high quality isotropic images. aEuro cent MS lesions are well demonstrated by 3D-MP-FLAIR and 3D-MP-DIR at 7 T MRI. aEuro cent 3D-MP-FLAIR and 3D-MP-DIR at 7 T MRI show many more Virchov-Robin spaces.
引用
收藏
页码:221 / 231
页数:11
相关论文
共 30 条
  • [1] Evidence for bulk flow of brain interstitial fluid: significance for physiology and pathology
    Abbott, NJ
    [J]. NEUROCHEMISTRY INTERNATIONAL, 2004, 45 (04) : 545 - 552
  • [2] Bagnato F, 2006, AM J NEURORADIOL, V27, P2161
  • [3] Fujita Hiroyuki, 2007, Magn Reson Med Sci, V6, P29, DOI 10.2463/mrms.6.29
  • [4] Grey matter pathology in multiple sclerosis
    Geurts, Jeroen J. G.
    Barkhof, Frederik
    [J]. LANCET NEUROLOGY, 2008, 7 (09) : 841 - 851
  • [5] Does high-field MR imaging improve cortical lesion detection in multiple sclerosis?
    Geurts, Jeroen J. G.
    Blezer, Erwin L. A.
    Vrenken, Hugo
    van der Toom, Annette
    Castelijns, Jonas A.
    Polman, Chris H.
    Pouwels, Petra J. W.
    Boe, Lars
    Barkhof, Frederik
    [J]. JOURNAL OF NEUROLOGY, 2008, 255 (02) : 183 - 191
  • [6] Intracortical lesions in multiple sclerosis: Improved detection with 3D double inversion-recovery MR imaging
    Geurts, JJG
    Pouwels, PJW
    Uitdehaag, BMJ
    Polman, CH
    Barkhof, F
    Castelijns, JA
    [J]. RADIOLOGY, 2005, 236 (01) : 254 - 260
  • [7] Quantitative In Vivo Magnetic Resonance Imaging of Multiple Sclerosis at 7 Tesla with Sensitivity to Iron
    Hammond, Kathryn E.
    Metcalf, Meredith
    Carvajal, Lucas
    Okuda, Darin T.
    Srinivasan, Radhika
    Vigneron, Dan
    Nelson, Sarah J.
    Pelletier, Daniel
    [J]. ANNALS OF NEUROLOGY, 2008, 64 (06) : 707 - 713
  • [8] Multiplicity of cerebrospinal fluid functions: New challenges in health and disease
    Johanson C.E.
    Duncan III J.A.
    Klinge P.M.
    Brinker T.
    Stopa E.G.
    Silverberg G.D.
    [J]. Cerebrospinal Fluid Research, 5 (1):
  • [9] Triple-Layer Appearance of Brodmann Area 4 at Thin-Section Double Inversion-Recovery MR Imaging
    Kim, Eung Yeop
    Kim, Dong-Hyun
    Chang, Jong-Hee
    Yoo, Eunhye
    Lee, Jae-Wook
    Park, Hae-Jeong
    [J]. RADIOLOGY, 2009, 250 (02) : 515 - 522
  • [10] First Clinical Study on Ultra-High-Field MR Imaging in Patients with Multiple Sclerosis: Comparison of 1.5T and 7T
    Kollia, K.
    Maderwald, S.
    Putzki, N.
    Schlamann, M.
    Theysohn, J. M.
    Kraff, O.
    Ladd, M. E.
    Forsting, M.
    Wanke, I.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) : 699 - 702