Obturation of root canals with different sealers using non-instrumentation technology

被引:14
作者
Lussi, A [1 ]
Imwinkelried, S [1 ]
Stich, H [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Operat Prevent & Paediat Dent, Bern, Switzerland
关键词
lateral condensation; leakage; root canal obturation; root canal preparation; vacuum technique;
D O I
10.1046/j.1365-2591.1999.00178.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate and compare the,sealing quality of hand- or vacuum-obturated root canals after hand preparation or hydrodynamic cleansing of root canals, respectively, Methodology After assessing root curvature, 96 single-rooted deep-frozen teeth were divided into eight comparable groups, The root canals of four groups were instrumented with the balanced force technique. The remaining uninstrumented teeth were connected to a reduced-pressure device (NIT) and the root-canal system perfused with 2.5% NaOCl under alternating pressure fields, This dissolved the pulpal tissues and removed debris from the root-canal system. The canals of the hand-instrumented groups were obturated using the cold lateral condensation method with guttapercha and one of four different sealers (AH26, AH Plus, Apexit and Pulp Canal Sealer EWT), The teeth treated with the alternating pressure device (NIT) were obturated by a vacuum obturation method (NIT) with the same four sealers. The quality of the coronal seal was assessed using a dye penetration method, In order to minimize errors the roots were perfused with water before exposure to the dye, under vacuum. The teeth were then rendered transparent and the depth of penetration of the dye between the wall of the canal and the obturating material was measured with a stereomicroscope. Results The canals cleaned and filled by NIT showed statistically significantly less dye penetration than those obturated by lateral condensation (P < 0.05), Within the NIT group, Pulp Canal Sealer EWT exhibited significantly more dye penetration than Apexit. Amongst the control lateral condensation groups no significant differences were found between the various sealers, Conclusions The present investigation demonstrated the validity of the NIT obturation method in combination with commonly used root-canal sealers.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 22 条
  • [1] DYE PENETRATION IN ROOT CANALS FILLED WITH AH26 IN DIFFERENT CONSISTENCIES
    BARTHEL, CR
    LOSCHE, GM
    ZIMMER, S
    ROULET, JF
    [J]. JOURNAL OF ENDODONTICS, 1994, 20 (09) : 436 - 439
  • [2] THE USEFULNESS OF DYE-PENETRATION STUDIES REEXAMINED
    GOLDMAN, M
    SIMMONDS, S
    RUSH, R
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 67 (03): : 327 - 332
  • [3] COMPARISON OF ROOT-CANAL PREPARATION USING DIFFERENT AUTOMATED DEVICES AND HAND INSTRUMENTATION
    HULSMANN, M
    STRYGA, F
    [J]. JOURNAL OF ENDODONTICS, 1993, 19 (03) : 141 - 145
  • [4] Langer SZ, 1985, J CARDIOVASC PHAR S8, V7, P1
  • [5] A NEW NONINSTRUMENTAL TECHNIQUE FOR CLEANING AND FILLING ROOT CANALS
    LUSSI, A
    MESSERLI, L
    HOTZ, P
    GROSREY, J
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (01) : 1 - 6
  • [6] Obturation of root canals in vivo with a new vacuum technique
    Lussi, A
    Suter, B
    Grosrey, J
    [J]. JOURNAL OF ENDODONTICS, 1997, 23 (10) : 629 - 631
  • [7] THE INFLUENCE OF DIFFERENT FACTORS ON IN-VITRO ENAMEL EROSION
    LUSSI, A
    JAGGI, T
    SCHARER, S
    [J]. CARIES RESEARCH, 1993, 27 (05) : 387 - 393
  • [8] LUSSI A, 1993, J ENDODONT, V19, P237
  • [9] LUSSI A, 1996, ENDODONTIE, V3, P189
  • [10] LUSSI A, 1998, IN PRESS J ENDODONTI