Thin-layer chromatography combined with diode laser thermal vaporization inductively coupled plasma mass spectrometry for the determination of selenomethionine and selenocysteine in algae and yeast

被引:12
|
作者
Bednarik, Antonin [1 ]
Kuta, Jan [2 ]
Vu, Dai Long [3 ]
Ranglova, Karolina [3 ]
Hrouzek, Pavel [3 ]
Kanicky, Viktor [1 ,4 ]
Preisler, Jan [1 ,4 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Chem, Kamenice 5, Brno 62500, Czech Republic
[2] Masaryk Univ, Fac Sci, Res Ctr Tox Cpds Environm RECETOX, Kamenice 5, Brno 62500, Czech Republic
[3] Czech Acad Sci, Ctr Algatech, Inst Microbiol, Novohradska 237, Trebon 37981, Czech Republic
[4] Masaryk Univ, Cent European Inst Technol CEITEC, Zerotinovo Nam 9, CS-60177 Brno, Czech Republic
关键词
Diode laser thermal vaporization (DLTV); Thin-layer chromatography (TLC); Liquid chromatography (LC); Inductively coupled plasma mass spectrometry (ICP MS); Selenium speciation (selenomethionine; selenocysteine); Chlorella vulgaris algae; ANION-EXCHANGE CHROMATOGRAPHY; CONTAINING AMINO-ACIDS; HPLC-ICP-MS; SELENIUM SPECIATION; CAPILLARY-ELECTROPHORESIS; ARSENIC SPECIATION; GAS-CHROMATOGRAPHY; BIOLOGICAL SAMPLES; INORGANIC SELENIUM; ABLATION;
D O I
10.1016/j.chroma.2017.12.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work we present a simple and cost-effective approach for the determination of selenium species in algae and yeast biomass, based on a combination of thin-layer chromatography (TLC) with diode laser thermal vaporization inductively coupled plasma mass spectrometry (DLTV ICP MS). Extraction of freeze-dried biomass was performed in 4M methanesulphonic acid and the selenium species were vaporized from cellulose TLC plates employing a continuous-wave infrared diode laser with power up to 4W using a simple laboratory-built apparatus. Selenomethionine and selenocysteine were quantified with limits of detection 3 mu g L-1 in a Se-enriched microalgae Chlorella vulgaris and yeast certified reference material SELM-1. Results delivered by TLC-DLTV ICP MS were consistent with those obtained by a routine coupling of high-performance liquid chromatography (HPLC) to ICP MS. In addition, the TLC approach is capable of analyzing extract containing even undiluted crude hydrolysates that could damage HPLC columns. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 207
页数:9
相关论文
共 50 条
  • [1] Thin-layer chromatography combined with diode laser thermal vaporization inductively coupled plasma mass spectrometry
    Bednarik, Antonin
    Tomalova, Iva
    Kanicky, Viktor
    Preisler, Jan
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1364 : 271 - 275
  • [2] Diode Laser Thermal Vaporization Inductively Coupled Plasma Mass Spectrometry
    Foltynova, Pavla
    Kanicky, Viktor
    Preisler, Jan
    ANALYTICAL CHEMISTRY, 2012, 84 (05) : 2268 - 2274
  • [3] Determination of selenomethionine, selenocysteine, and inorganic selenium in eggs by HPLC–inductively coupled plasma mass spectrometry
    Elżbieta Lipiec
    Grzegorz Siara
    Katarzyna Bierla
    Laurent Ouerdane
    Joanna Szpunar
    Analytical and Bioanalytical Chemistry, 2010, 397 : 731 - 741
  • [4] Determination of selenomethionine, selenocysteine, and inorganic selenium in eggs by HPLC-inductively coupled plasma mass spectrometry
    Lipiec, Elzbieta
    Siara, Grzegorz
    Bierla, Katarzyna
    Ouerdane, Laurent
    Szpunar, Joanna
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (02) : 731 - 741
  • [5] Speciation of inorganic arsenic by μ-thin-layer chromatography coupled with laser ablation inductively coupled plasma mass spectrometry based on an ion imprinted polymer
    Shushtarian, Mojgan Sadat
    Givianrad, Mohammad Hadi
    Tehrani, Mohammad Saber
    Aberoomand-Azar, Parviz
    ANALYTICAL METHODS, 2024, 16 (02) : 205 - 213
  • [6] Determination of Selenomethionine, Selenocystine, and Methylselenocysteine in Egg Sample by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
    Zhao, Yue
    Wang, Min
    Yang, Mengrui
    Zhou, Jian
    Wang, Tongtong
    SEPARATIONS, 2022, 9 (02)
  • [7] Determination of selenocystine, selenomethionine, selenite and selenate by high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry
    Quijano, MA
    Gutierrez, AM
    PerezConde, MC
    Camara, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (06) : 407 - 411
  • [8] Determination of metal uptake in single organisms, Corophium volutator, via complementary electrothermal vaporization/inductively coupled plasma mass spectrometry and laser ablation/inductively coupled plasma mass spectrometry
    von der Au, Marcus
    Karbach, Hannah
    Bell, Anna Maria
    Bauer, Oliver Bolle
    Karst, Uwe
    Meermann, Bjoern
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (02)
  • [9] Determination of Lead Species in Algae by Capillary Electrophoresis-Inductively Coupled Plasma-Mass Spectrometry
    Li Jing-Xi
    Sun Cheng-Jun
    Zheng Li
    Jiang Feng-Hua
    Yin Xiao-Fei
    Chen Jun-Hui
    Wang Xiao-Ru
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (11) : 1659 - 1664
  • [10] μ-Thin-layer chromatography coupled with laser ablation-inductively coupled plasma-mass spectrometry using tin(II)-imprinted polymer nanoparticles as a stationary phase for speciation of tin
    Kisomi, Amir Shafiee
    Alizadeh, Taher
    Shakeri, Alireza