Bioengineering reasons for the failure of metal-on-metal hip prostheses AN ENGINEER'S PERSPECTIVE

被引:62
|
作者
Fisher, J. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2011年 / 93B卷 / 08期
基金
英国工程与自然科学研究理事会;
关键词
WEAR DEBRIS; CUP ANGLE; MICROSEPARATION; REPLACEMENTS; BEARINGS; FRICTION; LUBRICATION;
D O I
10.1302/0301-620X.93B8.26936
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Bioengineering reasons for increased wear and failure of metal-on-metal (MoM) bearings in hip prostheses have been described. Low wear occurs in MoM hips when the centre of the femoral head is concentric with the centre of the acetabular component and the implants are correctly positioned. Translational or rotational malpositioning of the components can lead to the contact-patch of the femoral component being displaced to the rim of the acetabular component, resulting in a ten- to 100-fold increase in wear and metal ion levels. This may cause adverse tissue reactions, loosening of components and failure of the prosthesis.
引用
收藏
页码:1001 / 1004
页数:4
相关论文
共 50 条
  • [21] Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses
    Maskiewicz, Victoria K.
    Williams, Paul A.
    Prates, Sarah J.
    Bowsher, John G.
    Clarke, Ian C.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 94B (02) : 429 - 440
  • [22] Metal-on-Metal Total Hip Arthroplasty: Causes and High Incidence of Early Failure
    Fabi, David
    Levine, Brett
    Paprosky, Wayne
    Della Valle, Craig
    Sporer, Scott
    Klein, Gregg
    Levine, Harlan
    Hartzband, Mark
    ORTHOPEDICS, 2012, 35 (07) : E1009 - E1016
  • [23] Wear Simulation of Metal-on-Metal Hip Replacements With Frictional Contact
    Mattei, Lorenza
    Di Puccio, Francesca
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2013, 135 (02):
  • [24] Metal-on-metal hip implants and the risk of cancer
    Rosengren, Bjorn Erik
    BMJ-BRITISH MEDICAL JOURNAL, 2012, 345
  • [25] Effect of microseparation on contact mechanics in metal-on-metal hip replacementsA finite element analysis
    Liu, Feng
    Williams, Sophie
    Fisher, John
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (06) : 1312 - 1319
  • [26] High failure rate of the R3 metal-on-metal total hip arthroplasty
    Dramis, Asterios
    Clatworthy, Elizabeth
    Jones, Stephen A.
    John, Alun
    HIP INTERNATIONAL, 2014, 24 (05) : 442 - 447
  • [27] Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies
    Affatato, Saverio
    Traina, Francesco
    Ruggeri, Oddone
    Toni, Aldo
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (12) : 1155 - 1164
  • [28] The Long-Term Survivorship and Cause of Failure of Metal-on-Metal Total Hip Arthroplasty
    Wakabayashi, Hiroki
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    ANTIBIOTICS-BASEL, 2025, 14 (02):
  • [29] The Outcome of Revision Surgery for Failed Metal-on-Metal Total Hip Arthroplasty
    Borton, Zakk M.
    Mumith, Aadil S.
    Nicholls, Alex J.
    Pearce, Andrea R.
    Briant-Evans, Toby W.
    Griffiths, Jamie T.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (08) : 1749 - 1754
  • [30] Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint
    Scholes, S. C.
    Hunt, B. J.
    Richardson, V. M.
    Langton, D. J.
    Smith, E.
    Joyce, T. J.
    BONE & JOINT RESEARCH, 2017, 6 (02): : 113 - 122