Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [41] Three-phase state estimation of a distribution network based on multi-branch current mixing measurement
    Ge W.
    Cai Y.
    Li J.
    Cao C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (09): : 1 - 10
  • [42] A new approach to ungrounded fault location in a three-phase underground distribution system using combined neural networks & wavelet analysis
    Moshtagh, Jamal
    Aggarwal, R. K.
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 498 - +
  • [43] Power Flow Calculation of Three-phase Distribution Network Based on Constant Jacobian Matrix and Newton Method
    Wang, ShaoFang
    Liu, Guangyi
    Xu, Jie
    Lang, YanShen
    Yang, ZhangYong
    Dou, Chenlong
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [44] Fault location method for low voltage active distribution network based on phase-angle differences of the clark currents
    Niu, Geng
    Zhou, Long
    Pei, Wei
    Qi, Zhiping
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 : 15 - 24
  • [45] Fault Location in Double-Circuit Transmission Lines Compensated by Generalized Unified Power Flow Controller (GUPFC) Based on Synchronous Current and Voltage Phasors
    Abasi, Mahyar
    Saffarian, Alireza
    Joorabian, Mahmood
    Seifossadat, Seyyed Ghodratollah
    IEEE SYSTEMS JOURNAL, 2021, 15 (02): : 2190 - 2200
  • [46] Traveling-Wave Fault Location Techniques in Power System Based on Wavelet Analysis and Neural Network Using GPS Timing
    Mosavi, Mohammad-Reza
    Tabatabaei, Amir
    WIRELESS PERSONAL COMMUNICATIONS, 2016, 86 (02) : 835 - 850
  • [47] Power Flow Calculation for Unbalanced Three-phase Distribution Network with DGs Based on Phase-sequence Hybrid Modeling
    Yang, Xiong
    Wei, Zhinong
    Sun, Guoqiang
    Sun, Yonghui
    Yuan, Yang
    Lu, Zigang
    Xu, Xiaohui
    Huang, Li
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE), 2013,
  • [48] Artificial Neural Network-based Fault Location in Terminal-hybrid High Voltage Direct Current Transmission Lines
    Hadaeghi, A.
    Iliyaeifar, M. M.
    Chirani, A. Abdollahi
    INTERNATIONAL JOURNAL OF ENGINEERING, 2023, 36 (02): : 215 - 225
  • [49] Graph-Based Power Flow Algorithm for Three-Phase Distribution Network Considering Regulators and Distributed Generations
    Murari, Krishna
    Kamalasadan, Sukumar
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (04) : 5409 - 5422
  • [50] Line-to-Line Fault Analysis and Location in a VSC-Based Low-Voltage DC Distribution Network
    Xue, Shi-Min
    Liu, Chong
    ENERGIES, 2018, 11 (03)