Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [31] A Turn Fault Mitigation Strategy Based on Current Injection Technique for a Triple Three-Phase PMA SynRM
    Wang, Bo
    Wang, Jiabin
    Griffo, Antonio
    Huang, Lei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (04) : 2511 - 2522
  • [32] Fault detection, classification, and location for active distribution network based on neural network and phase angle analysis
    Zhang, Tong
    Liu, Jianchang
    Sun, Lanxiang
    Yu, Haibin
    Zhang, Yingwei
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2018, 41 (05) : 375 - 386
  • [33] A new approach to fault location in three-phase underground distribution system using combination of wavelet analysis with ANN and FLS
    Rafinia, Ali
    Moshtagh, Jamal
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 55 : 261 - 274
  • [34] A Novel Single-Phase-to-Ground Fault Location Method Based on Phase Current Differences in Power Distribution Systems
    Chang, Yongle
    Tang, Jinrui
    Li, Yang
    Xiong, Binyu
    Lu, Xiaotian
    Liu, Jianchao
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1196 - 1201
  • [35] Single phase line-broken fault detection and location based on differential voltage in radial distribution network
    Chang, Zhongxue
    Zeng, Zhihao
    Dou, Minna
    Zhang, Zhihua
    Song, Guobing
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (01) : 116 - 127
  • [36] A Transient Reconstructed Current-Instantaneous Correlation Factor Based Fault Section Location Method for Active Distribution Network
    Niu, Geng
    Ji, Yu
    Wu, Ming
    Kou, Lingfeng
    Sun, Lijing
    Li, Yijin
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [37] Single-phase-to-ground fault feeder identification based on the feature between voltage and integration of current
    Zhang, Shu
    He, Zhengyou
    Mai, Ruikun
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 12 (05) : 683 - 691
  • [38] Transmission line fault location based on three-phase state estimation framework considering measurement chain error model
    Ghaedi, Alireza
    Golshan, Mohammad Esmail Hamedani
    Sanaye-Pasand, Majid
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 178
  • [39] Fault Analysis for Distribution Networks With Current-Controlled Three-Phase Inverter-Interfaced Distributed Generators
    Wang, Qianggang
    Zhou, Niancheng
    Ye, Ling
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1532 - 1542
  • [40] Improved Three-phase Power Flow Model for Ungrounded Distribution Network Considering Controllability of Line-to-line Voltage
    Luo L.
    Zhao X.
    Yan W.
    Yu J.