Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [21] A Fault Location Method for Distribution network with DG System Based on Amplitude and Phase of the Current
    Zhao, Dongmei
    Zheng, Lixin
    Xu, Ruiqing
    Zhang, Xu
    2016 5TH INTERNATIONAL SYMPOSIUM ON NEXT-GENERATION ELECTRONICS (ISNE), 2016,
  • [22] Fault location in series capacitor compensated three-terminal transmission lines based on the analysis of voltage and current phasor equations and asynchronous data transfer
    Saffarian, Alireza
    Abasi, Mahyar
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187 (187)
  • [23] Nonfault Detection for Three-phase Reclosure in Reactor-compensated Transmission Lines Based on Fault Location
    Shao, Wenquan
    Liu, Yue
    Zhang, Wangni
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 974 - 977
  • [24] An interval power flow for unbalanced distribution systems based on the Three-Phase Current Method
    Rodrigues Junior, Heitor M.
    Melo, Igor D.
    Nepomuceno, Erivelton G.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 139
  • [25] Three-phase harmonic power flow algorithm of distribution network based on matrix paradigm
    Lin J.
    Zhang Y.
    Li C.
    Shao Z.
    Li K.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (04): : 165 - 171
  • [26] A Segmented Network Method Based Faulted Line Selection Strategy for Single-phase Earth Fault in Small Current Grounding Distribution Network
    Zhang, Hai
    Li, Jianfang
    Li, Yajie
    Zhang, Yanqi
    Lin, Tao
    Chen, Rusi
    Sheng, Yibiao
    Leng, Hua
    Zhang, Zhidan
    2017 INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS, ELECTRONICS AND CONTROL (ICCSEC), 2017, : 1582 - 1585
  • [27] High-impedance fault location method of three-phase distribution lines based on electromagnetic time reversal
    Sun, Jian
    Zhang, Xindong
    Wei, Siyu
    Luo, Qingliang
    Hu, Yi
    Yang, Qing
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 212
  • [28] Compensation of Systematic Errors for Improved PMU-Based Fault Detection and Location in Three-Phase Distribution Grids
    Pegoraro P.A.
    Sitzia C.
    Solinas A.V.
    Sulis S.
    Carta D.
    Benigni A.
    IEEE Transactions on Instrumentation and Measurement, 2024, 73
  • [29] Wavelet and Neural Network-Based Fault Location in Power Systems Using Statistical Analysis of Traveling Wave
    Mosavi, M. R.
    Tabatabaei, A.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (08) : 6207 - 6214
  • [30] Fault Location Method for Three-Terminal Lines in Distribution Network Based on Line Voltage Measured by μMPMU
    Yun, Zhihao
    Wen, Tao
    Wang, Chengbin
    IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (06) : 5095 - 5112