Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [1] Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated
    Masoud Dashtdar
    K. Sarada
    Seyed Mohammad Sadegh Hosseinimoghadam
    C. H. Naga Sai Kalyan
    A. N. Venkateswarlu
    B. Srikanth Goud
    C. H. Rami Reddy
    Youcef Belkhier
    Mohit Bajaj
    B. Nagi Reddy
    Journal of Electrical Engineering & Technology, 2022, 17 : 2631 - 2647
  • [2] A Fault Phase Selection for Distribution Network Based on Correlation Coefficient of Three-phase Transient Voltage
    Han, Xiaoyan
    Ren, Qin
    Shu, Qin
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 765 - 771
  • [3] Fault Current & Fault voltage Analysis of Power Distribution Network
    Kadam, S. R.
    Kale, R. U.
    Deokar, T. V.
    Pawar, P. B.
    2018 3RD INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [4] An algorithm for estimating fault location in an unbalanced three-phase power system
    Soliman, SA
    Abdel-Rahman, MH
    Al-Attar, E
    El-Hawary, ME
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (07) : 515 - 520
  • [5] A direct three-phase circuit analysis-based fault location for line-to-line fault
    Choi, Myeon-Song
    Lee, Seung-Jae
    Lim, Seong-Il
    Lee, Duck-Su
    Yang, Xia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2541 - 2547
  • [6] Power Network Fault Location Based on Voltage Magnitude Measurements and Sparse Estimation
    Zhu, Yuxuan
    Jia, Yixiong
    Liu, Yu
    Lu, Dayou
    2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [7] Novel Faulted Section Location Method for Distribution Network Based on Status Information of Fault Indicating Equipment
    Li, Guanbin
    Chen, Qing
    Zhang, Jianlei
    APPLIED SCIENCES-BASEL, 2020, 10 (17):
  • [8] Accurate fault location and faulted section determination based on deep learning for a parallel-compensated three-terminal transmission line
    Mirzaei, Mahdi
    Vahidi, Behrooz
    Hosseinian, Seyed Hossein
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (13) : 2770 - 2778
  • [9] Characteristic Analysis and Fault Segment Location on Negative Sequence Voltage and Current of Single Phase Line Breakage Fault in Distribution Network
    Chang Z.
    Song G.
    Zhang W.
    Dianwang Jishu/Power System Technology, 2020, 44 (08): : 3065 - 3072
  • [10] Fault Location in Active Distribution Network Based on the Change of Current Phase
    Zhang, Chen
    Liu, Zhong
    Huang, Jun
    Wang, Bo
    Wang, Xiangnv
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,