A novel whole-cell biosensor for the determination of trichloroethylene

被引:16
作者
Chee, Gab-Joo [1 ,2 ]
机构
[1] Dongyang Mirae Univ, Dept Biochem Engn, 445 Gyeongin Ro, Seoul 08221, South Korea
[2] Japan Agcy Marine Earth Sci & Technol, Inst Biogeosci, 2-15 Natsushima, Yokosuka, Kanagawa 2370061, Japan
关键词
Biosensor; Chloride ion electrode; Trichloroethylene; Toluene; Pseudomonas sp strain ASA86; PSEUDOMONAS-PUTIDA F1; TOLUENE DIOXYGENASE; DEGRADATION; BIODEGRADATION; BACTERIA; TCE; BIOREACTOR; OXIDATION; SENSOR;
D O I
10.1016/j.snb.2016.07.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trichloroethylene (TCE) is one of common pollutants in soil and groundwater. TCE has a recalcitrant pollutant that is uneasy to degrade by microorganisms. A novel microbial biosensor based on Pseudomonas sp. strain ASA86 was developed for the TCE detection. A chloride ion electrode was employed as a transducer to detect the released chloride ions from TCE degraded by the bacteria, which was immobilized on a porous cellulose nitrate membrane. The performance of the biosensor was evaluated at different TCE concentrations, with different concentrations of the immobilized bacteria, pH levels, temperatures, and with different interferents. There was a linear relationship between biosensor response and TCE concentration ranging up to 4 mg/L, and the response could be detected up to 0.05 mg/L TCE concentration. The biosensor response showed good reproducibility (relative standard deviation of 6.1%) at 0.5 mg/L TCE concentration. The detection time was about 5 min under the optimum conditions of the biosensor. The optimal response was obtained at pH 8.0 and 30 degrees C. Compounds that have molecular structures similar to that of TCE did not significantly affect the response of the biosensor. The biosensor response remained stable over five days. This TCE biosensor shows enough sensitivity for environmental monitoring. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:836 / 840
页数:5
相关论文
共 31 条
[1]   Some characteristics of bacteria found in a bioreactor to treat trichloroethylene contaminated groundwater [J].
Arai, K ;
Tsubone, T ;
Takechi, T ;
Inoue, T .
JOURNAL OF VETERINARY MEDICAL SCIENCE, 1999, 61 (03) :295-298
[2]  
Bouwer E. J., ENV SCI TECHNOL, P15
[3]   Biodegradation analyses of trichloroethylene (TCE) by bacteria and its use for biosensing of TCE [J].
Chee, Gab-Joo .
TALANTA, 2011, 85 (04) :1778-1782
[4]   Abiotic degradation of trichloroethylene under thermal remediation conditions [J].
Costanza, J ;
Davis, EL ;
Mulholland, JA ;
Pennell, KD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (17) :6825-6830
[5]  
ENSLEY BD, 1991, ANNU REV MICROBIOL, V45, P283
[6]   PERFORMANCE CHARACTERIZATION OF A MODEL BIOREACTOR FOR THE BIODEGRADATION OF TRICHLOROETHYLENE BY PSEUDOMONAS-CEPACIA-G4 [J].
FOLSOM, BR ;
CHAPMAN, PJ .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (06) :1602-1608
[7]   PHENOL AND TRICHLOROETHYLENE DEGRADATION BY PSEUDOMONAS-CEPACIA G4 - KINETICS AND INTERACTIONS BETWEEN SUBSTRATES [J].
FOLSOM, BR ;
CHAPMAN, PJ ;
PRITCHARD, PH .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1990, 56 (05) :1279-1285
[8]   FORMATION OF (+)-CIS-2,3-DIHYDROXY-1-METHYLCYCLOHEXA-4,6-DIENE FROM TOLUENE BY PSEUDOMONAS-PUTIDA [J].
GIBSON, DT ;
HENSLEY, M ;
YOSHIOKA, H ;
MABRY, TJ .
BIOCHEMISTRY, 1970, 9 (07) :1626-&
[9]   Development of a reactor type bio-sensor for trichloroethylene [J].
Han, TS ;
Sasaki, S ;
Yano, K ;
Ikebukuro, K ;
Atsushi, K ;
Nagamune, T ;
Karube, I .
ANALYTICAL LETTERS, 2003, 36 (03) :539-547
[10]   Flow injection microbial trichloroethylene sensor [J].
Han, TS ;
Sasaki, S ;
Yano, K ;
Ikebukuro, K ;
Kitayama, A ;
Nagamune, T ;
Karube, I .
TALANTA, 2002, 57 (02) :271-276