Hybrid Fault Location Method for Two Terminal Mixed Lines using One Ended Measurements

被引:0
|
作者
Naidu, O. D. [1 ]
Pradhan, A. K. [2 ]
机构
[1] ABB Corp, Res Ctr, Controls Res Area, Bangalore, Karnataka, India
[2] Indian Inst Technol, Dept Elect Engn, Kharagpur, W Bengal, India
关键词
Two-terminal mixed lines; Fault section identification; Fault location; Travelling wave; IMPEDANCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There has been a huge growth in the number of mixed lines mainly due to increased renewable integration to the grid. Mixed lines consist of overhead line (OHL) is connected to underground cable (UGC). This paper presents fault location method for mixed lines by combining power frequency (impedance) and traveling wave approaches. Four fault locations are determined based on first two traveling wave reflection times measured at one end of the mixed line and propagation velocities of the mixed line. Correct fault location is selected between the four using faulted sub-section information. Faulted sub-section is identified using the impedance-based method. Traveling waves are extracted from current measurement recorded in disturbance recorder (DR) using notch (Butterworth band pass) filter without using any special sensors. PSCAD/EMTDC simulation studies shows that proposed method is found to be very accurate. This method is unaffected by fault inception angles, arc resistances, fault locations, measurement noises and fault types.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Fault location for two- and three-terminal parallel lines using synchronized data
    Stamp, Jason
    Girgis, Adly A.
    International Journal of Power and Energy Systems, 1999, 19 (03): : 212 - 217
  • [32] An Accurate Fault Location Method/or Radial Distribution System Using One Terminal Data
    Naidu, O. D.
    George, Neethu
    Ashok, S.
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY, 2015, : 187 - 192
  • [33] One-Ended Fault Location Method Based on Machine Learning Models
    Pablo Bohorquez, Juan
    Ramos, Gustavo
    2019 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2019,
  • [34] Fault Location for Transmission Lines with Voltage and Current Measurements at One Bus
    Xiu, Wanjing
    Liao, Yuan
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2014, 15 (05) : 449 - 456
  • [35] A Synchrophasor-Based Fault Location Method for Three-Terminal Hybrid Transmission Lines With One Off-Service Line Branch
    Lee, Yu-Ju
    Chao, Ching-Hsin
    Lin, Tzu-Chiao
    Liu, Chih-Wen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 3249 - 3251
  • [36] Accurate fault location in three-terminal overhead lines using two-end synchronized measurements of voltage and current phasors
    Izykowski, Jan
    Bozek, Marcin
    MolĄg, Rapal
    Archives of Electrical Engineering, 2007, 56 (221-222): : 213 - 228
  • [37] Long Transmission Lines Fault Location Based on Parameter Identification Using One-Terminal Data
    Wang, Bin
    Suonan, Jiale
    Liu, Heqing
    Song, Guobing
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [38] Single Ended Fault Location Method for Lines Connected with Inverter Based Renewable Resources
    Naidu, O. D.
    Aarthi, V
    Likhitha, Kukkala
    2023 IEEE PES 15TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE, APPEEC, 2023,
  • [39] A Fault Location Method for Multi-terminal Transmission Lines Based on Multiple Current Measurements and Phase Comparison
    Zhang Yuanyuan
    Zhu Yongli
    Zhang Meng
    Zhang Ning
    PROCEEDINGS OF THE 2016 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING, MANUFACTURING TECHNOLOGY AND CONTROL, 2016, 67 : 428 - 431
  • [40] A physics-informed data-driven fault location method for transmission lines using single-ended measurements with field data validation
    Zou, Xinchen
    Xing, Yiqi
    Lu, Dayou
    He, Xuming
    Liu, Yu
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 236