Hybrid Fault Location Method for Two Terminal Mixed Lines using One Ended Measurements

被引:0
|
作者
Naidu, O. D. [1 ]
Pradhan, A. K. [2 ]
机构
[1] ABB Corp, Res Ctr, Controls Res Area, Bangalore, Karnataka, India
[2] Indian Inst Technol, Dept Elect Engn, Kharagpur, W Bengal, India
关键词
Two-terminal mixed lines; Fault section identification; Fault location; Travelling wave; IMPEDANCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There has been a huge growth in the number of mixed lines mainly due to increased renewable integration to the grid. Mixed lines consist of overhead line (OHL) is connected to underground cable (UGC). This paper presents fault location method for mixed lines by combining power frequency (impedance) and traveling wave approaches. Four fault locations are determined based on first two traveling wave reflection times measured at one end of the mixed line and propagation velocities of the mixed line. Correct fault location is selected between the four using faulted sub-section information. Faulted sub-section is identified using the impedance-based method. Traveling waves are extracted from current measurement recorded in disturbance recorder (DR) using notch (Butterworth band pass) filter without using any special sensors. PSCAD/EMTDC simulation studies shows that proposed method is found to be very accurate. This method is unaffected by fault inception angles, arc resistances, fault locations, measurement noises and fault types.
引用
收藏
页数:5
相关论文
共 50 条
  • [22] An accurate fault location algorithm for parallel transmission lines using one-terminal data
    Song Guobing
    Jiale, Suonan
    Ge Yaozhong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (2-3) : 124 - 129
  • [23] Fault location for parallel transmission lines using one-terminal current traveling waves
    徐青山
    Journal of Harbin Institute of Technology, 2009, 16 (03) : 408 - 412
  • [24] Study of fault location for parallel transmissions lines using one terminal current traveling waves
    Bian Haihong
    Xu Qingshan
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2296 - 2301
  • [25] Single-ended Fault Location Method for Overhead Cable Mixed Lines Connected with MMC-HVDC System
    Xue S.
    Lu J.
    Wang S.
    Sun Y.
    Liu C.
    Liu B.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (22): : 103 - 111
  • [26] A Single-Terminal Fault Location Method for HVDC Transmission Lines Based on a Hybrid Deep Network
    Wang, Lei
    He, Yigang
    Li, Lie
    ELECTRONICS, 2021, 10 (03) : 1 - 28
  • [27] Fault location on two-terminal transmission lines based on voltages
    Basque Country Univ, Bilbao, Spain
    IEE Proc Gener Transm Distrib, 1 (1-6):
  • [28] Wavelet Based Fault Location Technique for Two and Three Terminal Lines
    Megahed, A. I.
    Elrefaie, H. B.
    Moussa, A. Monem
    Marghany, Y. M.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [29] Fault location on two-terminal transmission lines based on voltages
    Zamora, I
    Minambres, JF
    Mazon, AJ
    ALvarezIsasi, R
    Lazaro, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) : 1 - 6
  • [30] A novel protection and fault location combined algorithm for mixed/hybrid lines
    Aminirad, Mohammad
    Shahrtash, S. Mohammad
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (10) : 2016 - 2031