Determination of Entrance Surface dose for Three Common Planar Diagnostic X-Ray Examinations

被引:1
|
作者
Jeyasugiththan, Jeyasingam [1 ]
Ehalagasthanna, G. P. N. T. [1 ]
Hishaam, Urshella [1 ]
Satharasinghe, D. M. [1 ]
机构
[1] Univ Colombo, Fac Sci, Dept Nucl Sci, Colombo 03, Sri Lanka
关键词
RADIOGRAPHY; QUALITY;
D O I
10.1093/rpd/ncac177
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Patient dose during diagnostic radiography procedures primarily depends on the entrance surface dose (ESD) and the exposure area. The purpose of this study was to determine ESD for five common diagnostic X-ray examinations using dose area product and X-ray tube output. The ESDs were estimated in a sample of 340 patients using normalised X-ray output from Philips-PrimaryDiagnost digital X-ray machine equipped with digital flat panel scintillator detector. The resultant mean ESDs for chest postero-anterior/lateral, lumbar spine antero-posterior (AP)/lateral and abdomen AP were 0.49, 2.00, 5.74, 12.79 and 4.62 mGy, respectively. The mean and third quartile ESD values of this study were significantly higher than the values found in the literature. This can be attributed to the lower tube potential (kV(p)) values and the higher tube current-time products (mAs). The methodology used here is a better option for low-resources countries for routine dose monitoring.
引用
收藏
页码:1361 / 1367
页数:7
相关论文
共 50 条
  • [31] Monte Carlo simulator of realistic x-ray beam for diagnostic applications
    Bontempi, Marco
    Andreani, Lucia
    Rossi, Pier Luca
    Visani, Andrea
    MEDICAL PHYSICS, 2010, 37 (08) : 4201 - 4209
  • [32] Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians
    Taqi, Ali H.
    Faraj, Kharman A.
    Zaynal, Sarah A.
    Hameed, Ahmed M.
    Mahmood, Abd-Alkader A.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 147 : 45 - 52
  • [33] Paediatric x-ray radiation dose reduction and image quality analysis
    Martin, L.
    Ruddlesden, R.
    Makepeace, C.
    Robinson, L.
    Mistry, T.
    Starritt, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 621 - 633
  • [34] X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
    Burion, Steve
    Funk, Tobias
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (55):
  • [35] X-ray examination dose surveys: how accurate are my results?
    Stephen Taylor
    Alain Van Muylem
    Nigel Howarth
    Pierre Alain Gevenois
    Denis Tack
    European Radiology, 2019, 29 : 5307 - 5313
  • [36] PAEDIATRIC RADIATION DOSE MEASUREMENTS UNDERGOING X-RAY EXAMINATION IN TASMANIA
    Agarwal, Vipul
    Newbery, Stephen
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 382 - 386
  • [37] Fetal radiation doses and subsequent risks from X-ray examinations: Should we be concerned?
    Chaparian, Ali
    Aghabagheri, Mahdi
    IRANIAN JOURNAL OF REPRODUCTIVE MEDICINE, 2013, 11 (11) : 899 - 904
  • [38] Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields
    Kelaranta, Anna
    Ekholm, Marja
    Toroi, Paula
    Kortesniemi, Mika
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
  • [39] Towards the establishment of national diagnostic reference levels for abdomen, KUB, and lumbar spine x-ray examinations in Sri Lanka: a multi-centric study
    Welarathna, Sachith
    Velautham, Sivakumar
    Sarasanandarajah, Sivananthan
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [40] X-ray examination dose surveys: how accurate are my results?
    Taylor, Stephen
    Van Muylem, Alain
    Howarth, Nigel
    Gevenois, Pierre Alain
    Tack, Denis
    EUROPEAN RADIOLOGY, 2019, 29 (10) : 5307 - 5313