Wear of PEEK-OPTIMA® and PEEK-OPTIMA®-Wear Performance articulating against highly cross-linked polyethylene

被引:32
作者
East, Rebecca H. [1 ]
Briscoe, Adam [2 ]
Unsworth, Anthony [3 ]
机构
[1] Kings Coll Hosp London, London, England
[2] Invibio Biomat Solut Ltd, Thornton Cleveleys, England
[3] Univ Durham, Sch Engn & Comp Sci, Durham DH1 3LE, England
关键词
Polymer on polymer tribology; polyetheretherketone against highly cross-linked polyethylene wear; ETHER-ETHER-KETONE; JOINT; REPLACEMENT; ITSELF;
D O I
10.1177/0954411915576353
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The idea of all polymer artificial joints, particularly for the knee and finger, has been raised several times in the past 20 years. This is partly because of weight but also to reduce stress shielding in the bone when stiffer materials such as metals or ceramics are used. With this in mind, pin-on-plate studies of various polyetheretherketone preparations against highly cross-linked polyethylene were conducted to investigate the possibility of using such a combination in the design of a new generation of artificial joints. PEEK-OPTIMA((R)) (no fibre) against highly cross-linked polyethylene gave very low wear factors of 0.0384x10(-6)mm(3)/N m for the polyetheretherketone pins and -0.025x10(-6)mm(3)/N m for the highly cross-linked polyethylene plates. The carbon-fibre-reinforced polyetheretherketone (PEEK-OPTIMA((R))-Wear Performance) also produced very low wear rates in the polyetheretherketone pins but produced very high wear in the highly cross-linked polyethylene, as might have been predicted since the carbon fibres are quite abrasive. When the fibres were predominantly tangential to the sliding plane, the mean wear factor was 0.052x10(-6)mm(3)/N m for the pins and 49.3x10(-6)mm(3)/N m for the highly cross-linked polyethylene plates; a half of that when the fibres ran axially in the pins (0.138x10(-6)mm(3)/N m for the pins and 97.5x10(-6)mm/ N m for the cross-linked polyethylene plates). PEEK-OPTIMA((R)) against highly cross-linked polyethylene merits further investigation.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 15 条
[1]   FTIR spectroscopic analysis of ion irradiated poly (ether ether ketone) [J].
Al Lafi, Abdul G. .
POLYMER DEGRADATION AND STABILITY, 2014, 105 :122-133
[2]   The influence of nominal stress on wear factors of carbon fibre-reinforced polyetheretherketone (PEEK-OPTIMA® Wear Performance) against zirconia toughened alumina (Biolox® delta ceramic) [J].
Evans, Andrew ;
Horton, Henrietta ;
Unsworth, Anthony ;
Briscoe, Adam .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (06) :587-592
[3]  
Joyce T J, 2005, J Appl Biomater Biomech, V3, P141
[4]  
Joyce T J, 1996, Proc Inst Mech Eng H, V210, P297, DOI 10.1243/PIME_PROC_1996_210_386_02
[5]  
Joyce TJ, 2000, BIO-MED MATER ENG, V10, P241
[6]  
Joyce TJ, 1996, J BONE JOINT SURG BR, V78, P40
[7]   Comparison between highly cross-linked and conventional polyethylene in total knee arthroplasty [J].
Minoda, Yukihide ;
Aihara, Masaharu ;
Sakawa, Akira ;
Fukuoka, Shinichi ;
Hayakawa, Keiko ;
Tomita, Masuhiro ;
Umeda, Naoya ;
Ohzono, Kenji .
KNEE, 2009, 16 (05) :348-351
[8]   Can a total knee replacement prosthesis be made entirely of polymers? [J].
Moore, DJ ;
Freeman, MAR ;
Revell, PA ;
Bradley, GW ;
Tuke, M .
JOURNAL OF ARTHROPLASTY, 1998, 13 (04) :388-395
[9]   Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head [J].
Scholes, S. C. ;
Inman, I. A. ;
Unsworth, A. ;
Jones, E. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H3) :273-283
[10]   The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine [J].
Scholes, S. C. ;
Unsworth, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H3) :281-289