Risk assessment of formaldehyde in typical office buildings in Taiwan

被引:42
作者
Wu, PC
Li, YY
Lee, CC
Chiang, CM
Su, HJJ
机构
[1] Natl Cheng Kung Univ, Coll Med, Grad Inst Environm & Occupat Hlth, Tainan 70428, Taiwan
[2] Natl Cheng Kung Univ, Coll Engn, Dept Architecture, Tainan 70428, Taiwan
关键词
formaldehyde; office building; risk assessment; lifetime cancer probability; hazard index; AIR; EXPOSURE;
D O I
10.1111/j.1600-0668.2003.00205.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Bruel Kjaer). The 8-h average concentrations in working hours were used to estimate the lifetime cancer probability (LCP) and chronic non-carcinogenic hazard index (HI). The carcinogenic effect of formaldehyde estimate by LCP (70 years old) is about 2.06 x 10(-4) to 1.75 x 10(-3) after adjusting their working time. The levels of risk are 100-1000 times of the acceptable carcinogenic risk. A similar trend is observed for the levels of HI calculated. Many studies have suggested that exposure to high levels of formaldehyde may cause nasal cancer and other health effects. Therefore, promoting the labeling system for low emission materials to protect consumers from exposure to excessive emissions and helping the industry to develop low emission materials is evidently urgent and deserves greater efforts.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 27 条
[1]   INDOOR AIR-POLLUTION DUE TO CHIPBOARD USED AS A CONSTRUCTION MATERIAL [J].
ANDERSEN, I ;
LUNDQVIST, GR ;
MOLHAVE, L .
ATMOSPHERIC ENVIRONMENT, 1975, 9 (12) :1121-1127
[2]  
[Anonymous], GUID CARC RISK ASS
[3]  
[Anonymous], AIR QUAL GUID EUR
[4]  
[Anonymous], 1998, Integrated Risk Information System
[5]  
*ASHRAE, 1999, 62 ASHRAE
[6]  
BREYSSE PA, 1985, INDOOR AIR, V3, P315
[7]  
*CA EPA, 1997, TECHN SUPP DOC DET N
[8]  
*CAPCOA, 1993, AIR TOX HOT SPOT PRO
[9]   Development and application of an indoor air quality audit to an air-conditioned building in Singapore [J].
Cheong, KW ;
Chong, KY .
BUILDING AND ENVIRONMENT, 2001, 36 (02) :181-188
[10]  
DALLY KA, 1981, ARCH ENVIRON HEALTH, V36, P277, DOI 10.1080/00039896.1981.10667638