Ultra high resolution X-ray detectors

被引:0
|
作者
Hess, U [1 ]
Bühler, M [1 ]
Von Hentig, R [1 ]
Hertrich, T [1 ]
Phelan, K [1 ]
Wernicke, D [1 ]
Höhne, J [1 ]
机构
[1] CSP Cryogen Spectrometers GmbH, D-85737 Ismaning, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CSP Cryogenic Spectrometers GmbH is developing cryogenic energy dispersive Xray spectrometers based on superconducting detector technology. Superconducting sensors exhibit at least a 10 fold improvement in energy resolution due to their low energy gap compared to conventional Si(Li) or Ge detectors. These capabilities are extremely valuable for the analysis of light elements and in general for the analysis of the low energy range of the Xray spectrum. The spectrometer is based on a mechanical cooler needing no liquid coolants and an adiabatic demagnetization refrigerator (ADR) stage which supplies the operating temperature of below 100 mK for the superconducting sensor. Applications include surface analysis in semiconductor industry as well material analysis for material composition e.g. in ceramics or automobile industry.
引用
收藏
页码:568 / 569
页数:2
相关论文
共 50 条
  • [41] Linearity investigations and pulse shape analysis of high resolution STJ X-ray detectors
    Huber, M
    Angloher, G
    von Feilitzsch, F
    Jagemann, T
    Jochum, J
    Lachenmaier, T
    Lanfranchi, JC
    Potzel, W
    Rüdig, A
    Schnagl, J
    Stark, M
    Wulandari, H
    LOW TEMPERATURE DETECTORS, 2002, 605 : 63 - 66
  • [42] On the use of CCD area detectors for high-resolution specular X-ray reflectivity
    Fenter, P.
    Catalano, J. G.
    Park, C.
    Zhang, Z.
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 293 - 303
  • [43] Silicon Drift Detectors and CUBE Preamplifiers for High-Resolution X-ray Spectroscopy
    Quaglia, R.
    Bombelli, L.
    Busca, P.
    Fiorini, C.
    Occhipinti, M.
    Giacomini, G.
    Ficorella, F.
    Picciotto, A.
    Piemonte, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 221 - 227
  • [44] Application of Low-Temperature Detectors to High-Resolution X-ray Spectroscopy
    Kilbourne, Caroline A.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 419 - 425
  • [45] HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT DETECTORS AND INTEGRATED ELECTRONICS
    BERTUCCIO, G
    SAMPIETRO, M
    FAZZI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 538 - 542
  • [46] Silicon carbide for high resolution X-ray detectors operating up to 100°C
    Bertuccio, G
    Casiraghi, R
    Cetronio, A
    Lanzieri, C
    Nava, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03): : 413 - 419
  • [47] Modular multichannel acquisition system for high-resolution X-ray spectroscopy detectors
    Guazzoni, C
    Buzzetti, S
    Longoni, A
    Arnaboldi, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1199 - 1203
  • [48] High resolution X-ray and infrared detectors using magnetic penetration depth thermometers
    Yeager, C.J.
    Finkbeiner, Fred
    Shirron, P.J.
    DiPirro, M.J.
    IEEE Transactions on Applied Superconductivity, 1999, 9 (2 III): : 3334 - 3337
  • [49] High resolution X-ray emission and X-ray absorption spectroscopy
    de Groot, F
    CHEMICAL REVIEWS, 2001, 101 (06) : 1779 - 1808
  • [50] HIGH RESOLUTION X-RAY DIFFRACTOMETER
    SYKORA, B
    PEISL, H
    ZEITSCHRIFT FUR ANGEWANDTE PHYSIK, 1970, 30 (04): : 320 - &