Introduction Arthrodesis of the distal interphalangeal joint (DIPJ) is an accepted operative procedure to treat osteoarthritis, instability and joint deformity. There is a wide spectrum of recommended operative techniques including cerclage wires, headless screws, bio-resorbable pins and lag screws. Lag screw fixation remains one of the most accepted methods of fixation; however, problems can occur in particular subsidence of the screw head leading to loss of compression and prominence of the screw head in the finger tip necessitating removal. We describe here a new technique of DIPJ arthrodesis that avoids these problems. Methods and patients The technique is described here in detail, and clinical results are given for 18 joints (17 patients) followed-up at a mean 24 months (range 6-44). Results Mean post-operative DASH score was 15. There were no cases of non-union; only four complications were seen, one case of nail growth disturbance and one of early screw breakage necessitating revision. Two infections necessitated early hardware removal although both arthodesis were united. Conclusion The technique is simple and reliable giving consistent clinical results.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 14 条
[1]   Arthrodesis of the distal interphalangeal joint using a bioabsorbable rod as an intramedullary nail [J].
Arata, J ;
Ishikawa, K ;
Soeda, H ;
Kitayama, T .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2003, 37 (04) :228-231
[2]  
Beaton D E, 2001, J Hand Ther, V14, P128
[3]   Use of a headless compressive screw for distal interphalangeal joint arthrodesis in digits: Clinical outcome and review of complications [J].
Brutus, JP ;
Palmer, AK ;
Mosher, JF ;
Harley, BJ ;
Loftus, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01) :85-89
[4]  
El-Hadidi Shaher, 2003, Hand Surg, V8, P21, DOI 10.1142/S0218810403001364
[5]   SMALL JOINT FUSIONS OF THE HAND USING THE HERBERT BONE SCREW [J].
FAITHFULL, DK ;
HERBERT, TJ .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1984, 9B (02) :167-168
[6]  
Germann G, 1999, Handchir Mikrochir Plast Chir, V31, P149, DOI 10.1055/s-1999-13902
[7]  
ISELIN F, 1972, NOUV PRESSE MED, V1, P1520
[8]  
Ishizuki Masafumi, 2002, Tech Hand Up Extrem Surg, V6, P200, DOI 10.1097/00130911-200212000-00008
[9]  
Lamas Gomez C, 2003, J South Orthop Assoc, V12, P154
[10]  
Offenbächer M, 2003, Z RHEUMATOL, V62, P168, DOI 10.1007/s00393-003-0461-7