Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement

被引:87
|
作者
Anderst, William J. [1 ]
Baillargeon, Emma [2 ]
Donaldson, William F., III [1 ]
Lee, Joon Y. [1 ]
Kang, James D. [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
关键词
accuracy; image registration; kinematics; RSA; x-ray; INTERVERTEBRAL MOTION; SAGITTAL PLANE; KINEMATICS; ROTATION; BIOMECHANICS; RADIATION; EXTENSION; TRACKING; FLEXION; CT;
D O I
10.1097/BRS.0b013e31820b7e2f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vivo validation during functional loading. Objective. To determine the accuracy and repeatability of a model-based tracking technique that combines subject-specific computed tomographic (CT) models and high-speed biplane x-ray images to measure three-dimensional (3D) in vivo cervical spine motion. Summary of Background Data. Accurate 3D spine motion is difficult to obtain in vivo during physiological loading because of the inability to directly attach measurement equipment to individual vertebrae. Previous measurement systems were limited by two-dimensional (2D) results and/or their need for manual identification of anatomical landmarks, precipitating unreliable and inaccurate results. All previous techniques lack the ability to capture true 3D motion during dynamic functional loading. Methods. Three subjects had 1.0-mm-diameter tantalum beads implanted into their fused and adjacent vertebrae during anterior cervical discectomy and fusion surgery. High-resolution CT scans were obtained after surgery and used to create subject-specific 3D models of each cervical vertebra. Biplane x-ray images were collected at 30 frames per second while the subjects performed flexion/extension and axial rotation movements 6 months after surgery. Individual bone motion, intervertebral kinematics, and arthrokinematics derived from dynamic radiostereophotogrammetric analysis served as a gold standard to evaluate the accuracy of the model-based tracking technique. Results. Individual bones were tracked with an average precision of 0.19 and 0.33 mm in nonfused and fused bones, respectively. Precision in measuring 3D joint kinematics in fused and adjacent segments averaged 0.4 mm for translations and 1.1 degrees for rotations, while anterior and posterior disc height above and below the fusion were measured with a precision ranging between 0.2 and 0.4 mm. The variability in 3D joint kinematics associated with tracking the same trial repeatedly was 0.02 mm in translation and 0.06 degrees in rotation. Conclusion. The 3D cervical spine motion can be precisely measured in vivo with submillimeter accuracy during functional loading without the need for bead implantation. Fusion instrumentation did not diminish the accuracy of kinematic and arthrokinematic results. The semiautomated model-based tracking technique has excellent repeatability.
引用
收藏
页码:E393 / E400
页数:8
相关论文
共 50 条
  • [21] Three-dimensional analysis of cervical spine segmental motion in rotation
    Zhao, Xiong
    Wu, Zi-xiang
    Han, Bao-jun
    Yan, Ya-bo
    Zhang, Yang
    Lei, Wei
    ARCHIVES OF MEDICAL SCIENCE, 2013, 9 (03) : 515 - 520
  • [22] Registration of three-dimensional MR and CT studies of the cervical spine
    Panigrahy, A
    Caruthers, SD
    Krejza, J
    Barnes, PD
    Faddoul, SG
    Sleeper, LA
    Melhem, ER
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (02) : 282 - 289
  • [23] Influence of cranio-cervical posture on three-dimensional motion of the cervical spine
    Edmondston, SJ
    Henne, SE
    Loh, W
    Ostvold, E
    MANUAL THERAPY, 2005, 10 (01) : 44 - 51
  • [24] Bootstrap prediction bands for cervical spine intervertebral kinematics during in vivo three-dimensional head movements
    Anderst, William J.
    JOURNAL OF BIOMECHANICS, 2015, 48 (07) : 1270 - 1276
  • [25] Three-dimensional in vivo measurement of lumbar spine segmental motion
    Ochia, Ruth S.
    Inoue, Nozomu
    Renner, Susan M.
    Lorenz, Eric P.
    Lim, Tae-Hong
    Andersson, Gunnar B. J.
    An, Howard S.
    SPINE, 2006, 31 (18) : 2073 - 2078
  • [26] Describing three-dimensional cervical spine movement in a diseased and a non-diseased group using multilevel modelling
    Jordan, K
    Jones, PW
    Dziedzic, K
    STATISTICS IN MEDICINE, 2003, 22 (14) : 2365 - 2380
  • [27] A new technique for the three-dimensional study of the spine in vitro and in vivo by using a motion-analysis system
    Liu, XC
    Fabry, G
    Labey, L
    VanDenBerghe, L
    VanAudekercke, R
    Molenaers, G
    Moens, P
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (04): : 329 - 338
  • [28] Development and Validation of a Three-Dimensional Finite Element Model of Cervical Spine (C3-C5)
    Bahramshahi, N.
    Ghaemi, H.
    Behdinan, K.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 2, 2012, : 167 - 174
  • [29] Effects of orthoses on three-dimensional load–displacement properties of the cervical spine
    Paul C. Ivancic
    European Spine Journal, 2013, 22 : 169 - 177
  • [30] THREE-DIMENSIONAL IN-VIVO CERVICAL SPINE KINEMATICS: PRELIMINARY COMPARISON OF FUSION PATIENTS AND NORMAL CONTROL SUBJECTS
    McDonald, Colin P.
    Bilkhu, Sukhinder K.
    Chang, Victor
    Bachison, Casey
    Bartol, Stephen W.
    Bey, Michael J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 193 - 194