Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement

被引:88
作者
Anderst, William J. [1 ]
Baillargeon, Emma [2 ]
Donaldson, William F., III [1 ]
Lee, Joon Y. [1 ]
Kang, James D. [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
关键词
accuracy; image registration; kinematics; RSA; x-ray; INTERVERTEBRAL MOTION; SAGITTAL PLANE; KINEMATICS; ROTATION; BIOMECHANICS; RADIATION; EXTENSION; TRACKING; FLEXION; CT;
D O I
10.1097/BRS.0b013e31820b7e2f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vivo validation during functional loading. Objective. To determine the accuracy and repeatability of a model-based tracking technique that combines subject-specific computed tomographic (CT) models and high-speed biplane x-ray images to measure three-dimensional (3D) in vivo cervical spine motion. Summary of Background Data. Accurate 3D spine motion is difficult to obtain in vivo during physiological loading because of the inability to directly attach measurement equipment to individual vertebrae. Previous measurement systems were limited by two-dimensional (2D) results and/or their need for manual identification of anatomical landmarks, precipitating unreliable and inaccurate results. All previous techniques lack the ability to capture true 3D motion during dynamic functional loading. Methods. Three subjects had 1.0-mm-diameter tantalum beads implanted into their fused and adjacent vertebrae during anterior cervical discectomy and fusion surgery. High-resolution CT scans were obtained after surgery and used to create subject-specific 3D models of each cervical vertebra. Biplane x-ray images were collected at 30 frames per second while the subjects performed flexion/extension and axial rotation movements 6 months after surgery. Individual bone motion, intervertebral kinematics, and arthrokinematics derived from dynamic radiostereophotogrammetric analysis served as a gold standard to evaluate the accuracy of the model-based tracking technique. Results. Individual bones were tracked with an average precision of 0.19 and 0.33 mm in nonfused and fused bones, respectively. Precision in measuring 3D joint kinematics in fused and adjacent segments averaged 0.4 mm for translations and 1.1 degrees for rotations, while anterior and posterior disc height above and below the fusion were measured with a precision ranging between 0.2 and 0.4 mm. The variability in 3D joint kinematics associated with tracking the same trial repeatedly was 0.02 mm in translation and 0.06 degrees in rotation. Conclusion. The 3D cervical spine motion can be precisely measured in vivo with submillimeter accuracy during functional loading without the need for bead implantation. Fusion instrumentation did not diminish the accuracy of kinematic and arthrokinematic results. The semiautomated model-based tracking technique has excellent repeatability.
引用
收藏
页码:E393 / E400
页数:8
相关论文
共 23 条
[1]   Validation of three-dimensional model-based tibio-femoral tracking during running [J].
Anderst, William ;
Zauel, Roger ;
Bishop, Jennifer ;
Demps, Erinn ;
Tashman, Scott .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) :10-16
[2]  
[Anonymous], STAND PRACT US TERMS
[3]   Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics [J].
Bey, Michael J. ;
Zauel, Roger ;
Brock, Stephanie K. ;
Tashman, Scott .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :604-609
[4]   Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion [J].
Bey M.J. ;
Kline S.K. ;
Tashman S. ;
Zauel R. .
Journal of Orthopaedic Surgery and Research, 3 (1)
[5]   Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[6]   Biomechanics of the cervical spine. I: Normal kinematics [J].
Bogduk, N ;
Mercer, S .
CLINICAL BIOMECHANICS, 2000, 15 (09) :633-648
[7]   Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know [J].
Brenner, DJ ;
Doll, R ;
Goodhead, DT ;
Hall, EJ ;
Land, CE ;
Little, JB ;
Lubin, JH ;
Preston, DL ;
Preston, RJ ;
Puskin, JS ;
Ron, E ;
Sachs, RK ;
Samet, JM ;
Setlow, RB ;
Zaider, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :13761-13766
[8]  
Dunsker S B, 1978, Clin Neurosurg, V25, P174
[9]   FUNCTIONAL RADIOGRAPHIC DIAGNOSIS OF THE CERVICAL-SPINE - FLEXION EXTENSION [J].
DVORAK, J ;
FROEHLICH, D ;
PENNING, L ;
BAUMGARTNER, H ;
PANJABI, MM .
SPINE, 1988, 13 (07) :748-755
[10]   Sagittal plane segmental motion of the cervical spine. A new precision measurement protocol and normal motion data of healthy adults [J].
Frobin, W ;
Leivseth, G ;
Biggemann, M ;
Brinckmann, P .
CLINICAL BIOMECHANICS, 2002, 17 (01) :21-31