Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement

被引:88
|
作者
Anderst, William J. [1 ]
Baillargeon, Emma [2 ]
Donaldson, William F., III [1 ]
Lee, Joon Y. [1 ]
Kang, James D. [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
关键词
accuracy; image registration; kinematics; RSA; x-ray; INTERVERTEBRAL MOTION; SAGITTAL PLANE; KINEMATICS; ROTATION; BIOMECHANICS; RADIATION; EXTENSION; TRACKING; FLEXION; CT;
D O I
10.1097/BRS.0b013e31820b7e2f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vivo validation during functional loading. Objective. To determine the accuracy and repeatability of a model-based tracking technique that combines subject-specific computed tomographic (CT) models and high-speed biplane x-ray images to measure three-dimensional (3D) in vivo cervical spine motion. Summary of Background Data. Accurate 3D spine motion is difficult to obtain in vivo during physiological loading because of the inability to directly attach measurement equipment to individual vertebrae. Previous measurement systems were limited by two-dimensional (2D) results and/or their need for manual identification of anatomical landmarks, precipitating unreliable and inaccurate results. All previous techniques lack the ability to capture true 3D motion during dynamic functional loading. Methods. Three subjects had 1.0-mm-diameter tantalum beads implanted into their fused and adjacent vertebrae during anterior cervical discectomy and fusion surgery. High-resolution CT scans were obtained after surgery and used to create subject-specific 3D models of each cervical vertebra. Biplane x-ray images were collected at 30 frames per second while the subjects performed flexion/extension and axial rotation movements 6 months after surgery. Individual bone motion, intervertebral kinematics, and arthrokinematics derived from dynamic radiostereophotogrammetric analysis served as a gold standard to evaluate the accuracy of the model-based tracking technique. Results. Individual bones were tracked with an average precision of 0.19 and 0.33 mm in nonfused and fused bones, respectively. Precision in measuring 3D joint kinematics in fused and adjacent segments averaged 0.4 mm for translations and 1.1 degrees for rotations, while anterior and posterior disc height above and below the fusion were measured with a precision ranging between 0.2 and 0.4 mm. The variability in 3D joint kinematics associated with tracking the same trial repeatedly was 0.02 mm in translation and 0.06 degrees in rotation. Conclusion. The 3D cervical spine motion can be precisely measured in vivo with submillimeter accuracy during functional loading without the need for bead implantation. Fusion instrumentation did not diminish the accuracy of kinematic and arthrokinematic results. The semiautomated model-based tracking technique has excellent repeatability.
引用
收藏
页码:E393 / E400
页数:8
相关论文
共 50 条
  • [1] Three-dimensional flexibility characteristics of the human cervical spine in vivo
    McClure, P
    Siegler, S
    Nobilini, R
    SPINE, 1998, 23 (02) : 216 - 223
  • [2] Kinematics of the cervical spine in lateral bending in vivo three-dimensional analysis
    Ishii, T
    Mukai, Y
    Hosono, N
    Sakaura, H
    Fujii, R
    Nakajima, Y
    Tamura, S
    Iwasaki, M
    Yoshikawa, H
    Sugamoto, K
    SPINE, 2006, 31 (02) : 155 - 160
  • [3] Kinematics of the subaxial cervical spine in rotation in vivo three-dimensional analysis
    Ishii, T
    Mukai, Y
    Hosono, N
    Sakaura, H
    Fujii, R
    Nakajima, Y
    Tamura, S
    Sugamoto, K
    Yoshikawa, H
    SPINE, 2004, 29 (24) : 2826 - 2831
  • [4] Kinematics of the upper cervical spine in rotation -: In vivo three-dimensional analysis
    Ishii, T
    Mukai, Y
    Hosono, N
    Sakaura, H
    Nakajima, Y
    Sato, Y
    Sugamoto, K
    Yoshikawa, H
    SPINE, 2004, 29 (07) : E139 - E144
  • [5] Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics
    Crisco, TJ
    McGovern, RD
    Wolfe, SW
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (01) : 96 - 100
  • [6] In vivo three-dimensional kinematics of the cervical spine during maximal axial rotation
    Salem, Walid
    Lenders, Cyrille
    Mathieu, Jacques
    Hermanus, Nicole
    Klein, Paul
    MANUAL THERAPY, 2013, 18 (04) : 339 - 344
  • [7] Cervical Spine Disc Deformation During In Vivo Three-Dimensional Head Movements
    William Anderst
    William Donaldson
    Joon Lee
    James Kang
    Annals of Biomedical Engineering, 2016, 44 : 1598 - 1612
  • [8] Cervical Spine Disc Deformation During In Vivo Three-Dimensional Head Movements
    Anderst, William
    Donaldson, William
    Lee, Joon
    Kang, James
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (05) : 1598 - 1612
  • [9] In Vivo Three-Dimensional Kinematics of the Cervical Spine During Head Rotation in Patients With Cervical Spondylosis
    Nagamoto, Yukitaka
    Ishii, Takahiro
    Sakaura, Hironobu
    Iwasaki, Motoki
    Moritomo, Hisao
    Kashii, Masafumi
    Hattori, Takako
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    SPINE, 2011, 36 (10) : 778 - 783
  • [10] Validation of a software to measure the true three-dimensional length of the spine from radiographic images
    Hasler, Carol
    Berger, Steve
    Buchler, Philippe
    SWISS MEDICAL WEEKLY, 2017, 147 : 2S - 2S