A patient-specific 3D model of the knee to compare the femoral rollback before and after total knee arthroplasty (TKA)

被引:7
作者
Mercader, Alexandra [1 ]
Roettinger, Timon [2 ]
Bigdeli, Amir [2 ]
Lueth, Tim C. [1 ]
Roettinger, Heinz [2 ]
机构
[1] Tech Univ Munich, Boltzmannstr 15, D-85748 Garching, Germany
[2] Chirurg Klinikum Munchen, Munich Ctr Arthroplasty, Sud Isarkanal 30, D-81379 Munich, Germany
关键词
Total knee Arthroplasty; Mechanism design; Rollback effect; COMPONENT ROTATION; KINEMATICS; ALIGNMENT; MOTION;
D O I
10.1186/s40634-020-00319-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Total knee arthroplasty (TKA) is nowadays performed as a standard procedure on a large number of patients suffering from arthrosis. Replacing the knee joint causes changes in the geometry and kinematics of the knee, which are unique to each individual. This research focuses on the method to detect these changes after TKA and on the impact on the knee movement. This approach could reduce complications in patients with post-operative pain and reduce the number of revisions. Methods A 3D model of a patient's knee was made by measuring the movement with a medically certified infrared stereo camera. This measurement was combined with the 3D model of the patient's bones, previously segmented from the CT scan. This model is printed in 3D, one part being the mechanism that follows the movement of the patient, and the other part being the 3D copy of the femur and tibia bones. The knee replacement operation is performed directly on the model and the resulting rollback is being measured before and after TKA. Results We observe a difference in the rollback before and after TKA on the 3D printed model. The variation in size and shape of the femoral implant compared to the natural femur condyles is one of the reasons for the changes in the rollback effect. The rollback is half as large after the prosthesis insertion, which confirms the fact that the femoral prosthesis geometry influences the knee kinematics. Conclusions In this study, a first 3D model combining the patient-specific kinematic and the geometry of his bones has been constructed. This model allows the surgeon to validate the plan of the operation, but also to understand the problems and consequences generated by the prosthesis insertion. The rollback is one of the most important motion of the knee joint and this behavior could be quantified, providing comparative analysis of the knee joint before and after the operation. As a future study, the model could be used to analyse more parameters of the TKA such as the impact of different implantation methods.
引用
收藏
页数:10
相关论文
共 39 条
[1]   Measured Resection Versus Gap Balancing for Total Knee Arthroplasty [J].
Abdel, Matthew P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (07) :2016-2022
[2]   The Impact of Mechanical and Restricted Kinematic Alignment on Knee Anatomy in Total Knee Arthroplasty [J].
Almaawi, Abdulaziz M. ;
Hutt, Jonathan R. B. ;
Masse, Vincent ;
Lavigne, Martin ;
Vendittoli, Pascal-Andre .
JOURNAL OF ARTHROPLASTY, 2017, 32 (07) :2133-2140
[3]   Kinematic and Kinetic Waveform Changes of the Knee Joint Following a Mobile Bearing Total Knee Arthroplasty-Gait Analysis and Single Step Ascent [J].
Apostolopoulos, A. P. ;
Chronopoulos, E. ;
Michos, I. V. ;
Mastrokalos, D. ;
Darras, N. ;
Nikolaou, V. S. .
JOURNAL OF KNEE SURGERY, 2020, 33 (10) :978-986
[4]   Knee motion symmetry was not restored in patients with unilateral bi-cruciate retaining total knee arthroplastyin vivo three-dimensional kinematic analysis [J].
Arauz, Paul ;
Peng, Yun ;
Kwon, Young-Min .
INTERNATIONAL ORTHOPAEDICS, 2018, 42 (12) :2817-2823
[5]   Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy [J].
Baka, Nora ;
Kaptein, Bart L. ;
Giphart, J. Erik ;
Staring, Marius ;
de Bruijne, Marleen ;
Lelieveldt, Boudewijn P. F. ;
Valstar, Edward .
JOURNAL OF BIOMECHANICS, 2014, 47 (01) :122-129
[6]  
Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
[7]   Improving outcomes in total knee arthroplasty-do navigation or customized implants have a role? [J].
Beal, Matthew D. ;
Delagramaticas, Dimitri ;
Fitz, David .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
[8]   Kinematic alignment in total knee arthroplasty better reproduces normal gait than mechanical alignment [J].
Blakeney, William ;
Clement, Julien ;
Desmeules, Francois ;
Hagemeister, Nicola ;
Riviere, Charles ;
Vendittoli, Pascal-Andre .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) :1410-1417
[9]   PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study [J].
Calliess, Tilman ;
Bauer, Kamil ;
Stukenborg-Colsman, Christina ;
Windhagen, Henning ;
Budde, Stefan ;
Ettinger, Max .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) :1743-1748
[10]   How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review [J].
De Valk, Eduard J. ;
Noorduyn, Julia C. A. ;
Mutsaerts, Eduard L. A. R. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) :3517-3528