A comparison of the disposable versus the reusable laryngeal mask airway in paralyzed adult patients

被引:64
作者
Brimacombe, J
Keller, C
Morris, R
Mecklem, D
机构
[1] Cairns Base Hosp, Dept Anaesthesia & Intens Care, Cairns, Australia
[2] Leopold Franzens Univ, Dept Anaesthesia & Intens Care Med, Innsbruck, Austria
关键词
D O I
10.1097/00000539-199810000-00033
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A disposable (polyvinyl chloride) laryngeal mask airway (LMA) with dimensions identical to, but physical properties different from (stiffer tube/thicker cuff), the reusable (silicone) LMA has recently become available. We performed a randomized, cross-over study of 60 paralyzed, anesthetized patients to test the hypothesis that the use of these devices was different in terms of ease of insertion, airway sealing pressure, fiberoptic position, and changes in intracuff pressure during N2O anesthesia. We also tested the hypothesis that the airway sealing pressure of the LMA is suboptimal if the cuff is inflated to a high intracuff pressure. Both the devices were inserted into each patient in random order, and their performance was assessed at two intracuff pressures (60 and 180 cm H2O) by a blind observer. Subsequently, intracuff pressures were measured during N2O anesthesia for the second device. Ease of insertion was similar: there was no difference in first attempt success rates (97% vs 98%) and insertion times (15 vs 13 s) for the disposable and reusable LMA, respectively. There were no differences in airway sealing pressure or fiberoptic position. Airway sealing pressure was significantly higher at 60 cm H2O intracuff pressure compared with the airway sealing pressure at 180 cm H2O for both devices (P < 0.02). During N2O anesthesia, the intracuff pressure remained stable for the disposable LMA but increased significantly for the reusable LMA. We conclude that the disposable and reusable LMAs perform similarly in paralyzed adult patients, but that the disposable LMA has more stable intracuff pressures during N2O anesthesia, inflation of the LMA to high intracuff pressures produces a subpotimal seal. Implications: This randomized, single-blind, within-patient study of 60 adult patients shows that the disposable (polyvinyl chloride) and reusable (silicone) laryngeal mask airways perform similarly, but that the disposable laryngeal mask airway has more stable intracuff pressures during N2O anesthesia. Inflation of either device to high intracuff pressures produces a suboptimal seal.
引用
收藏
页码:921 / 924
页数:4
相关论文
共 15 条
  • [1] Laryngeal mask airway and the ASA difficult airway algorithm
    Benumof, JL
    [J]. ANESTHESIOLOGY, 1996, 84 (03) : 686 - 699
  • [2] BIGNELL S, 1994, ANAESTH INTENSIVE CA, V22, P745
  • [3] BRIMACOMBE J, 1993, ANESTH ANALG, V76, P457
  • [4] NEUROMUSCULAR BLOCK AND INSERTION OF THE LARYNGEAL MASK AIRWAY
    BRIMACOMBE, J
    BERRY, A
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (01) : 166 - 167
  • [5] Brimacombe J, 1996, LARYNGEAL MASK AIRWA, V3rd
  • [6] A comparison of the laryngeal mask airway and cuffed oropharyngeal airway in anesthetized adult patients
    Brimacombe, JR
    Brimacombe, JC
    Berry, AM
    Morris, R
    Mecklem, D
    Clarke, G
    Barry, J
    Kirk, T
    [J]. ANESTHESIA AND ANALGESIA, 1998, 87 (01) : 147 - 152
  • [7] Brimacombe JR, 1997, The Laryngeal Mask Airway: A Review and Practical Guide
  • [8] THE LARYNGEAL MASK AIRWAY AND POSITIVE-PRESSURE VENTILATION
    DEVITT, JH
    WENSTONE, R
    NOEL, AG
    ODONNELL, MP
    [J]. ANESTHESIOLOGY, 1994, 80 (03) : 550 - 555
  • [9] THE EFFECT OF NITROUS-OXIDE ON LARYNGEAL MASK CUFF PRESSURE - INVITRO AND INVIVO STUDIES
    LUMB, AB
    WRIGLEY, MW
    [J]. ANAESTHESIA, 1992, 47 (04) : 320 - 323
  • [10] The effect of laryngeal mask airway insertion on the position of the internal jugular vein
    Nandwani, N
    Fairfield, MC
    Krarup, K
    Thompson, J
    [J]. ANAESTHESIA, 1997, 52 (01) : 77 - 79