Robust strategies for automated AFM force curve Analysis-II: Adhesion-influenced indentation of soft, elastic materials

被引:115
作者
Lin, David C.
Dmitriadis, Emilios K. [1 ]
Horkay, Farenc [1 ]
机构
[1] Natl Inst Biomed Imaging & Bioengn, NIH, Bethesda, MD 20892 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 06期
关键词
adhesive contact; atomic force microscopy; contact mechanics; elasticity; indentation;
D O I
10.1115/1.2800826
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the first of this two-part discourse on the extraction of elastic properties from atomic force microscopy (AFM) data, a scheme,for automating the analysis of force-distance curves was introduced and experimentally validated for the Hertzian (i.e., linearly elastic and noninteractive probe-sample pairs) indentation of soft, inhomogeneous materials. In the presence of probe-sample adhesive interactions, which are common especially during retraction of the rigid tip from soft materials, the Hertzian models are no longer adequate. A number of theories (e.g., Johnson-Kendall-Roberts and Derjaguin-Muller-Toporov), covering the full range of sample compliance relative to adhesive force and tip radius, are available for analysis of such data. We incorporated Pietrement and Troyon's approximation (2000, "General Equations Describing Elastic Indentation Depth and Normal Contact Stiffness Versus Load, " J. Colloid Interface Sci., 226(1), pp. 166-171) of the Maugis-Dugdale model into the automated procedure. The scheme developed for the processing of Hertzian data was extended to allow for adhesive contact by applying the Pietrement-Troyon equation. Retraction force-displacement data from the indentation of polyvinyl alcohol gels were processed using the customized software. Many of the retraction curves exhibited strong adhesive interactions that were absent in extension. We compared the values of Young's modulus extracted from the retraction data to the values obtained from the extension data and tom macroscopic uniaxial compression tests. Application of adhesive contact models and the automated scheme to the retraction curves yielded average values of Young's modulus close to those obtained with Hertzian models for the extension curves. The Pietrement-Troyon equation provided a good fit to the data as indicated by small values of the mean-square error. The Maugis-Dugdale theory is capable of accurately modeling adhesive contact between a rigid spherical indenter and a soft, elastic sample. Pietrement and Troyon's empirical equation greatly simplifies the theory and renders it compatible with the general automation strategies that we developed for Hertzian analysis. Our comprehensive algorithm for automated extraction of Young's moduli from AFM indentation data has been expanded to recognize the presence of either adhesive or Hertzian behavior and apply the appropriate contact model.
引用
收藏
页码:904 / 912
页数:9
相关论文
共 24 条