The assessment of environmental conditioning techniques and their energy performance in historic churches located in Mediterranean climate

被引:29
|
作者
Ma Munoz-Gonzalez, Carmen [1 ]
Leon-Rodriguez, A. L. [1 ]
Campano-Laborda, M. [1 ]
Teeling, C. [1 ]
Baglioni, R. [1 ]
机构
[1] Univ Seville, Escuela Tecn Super Arquitectura, Inst Univ Arquitectura & Ciencias Construcc, AV Reina Mercedes S-N, E-41012 Seville, Spain
关键词
Hygrothermal building simulation; Energy efficiency; Modelling; HVAC; Historic buildings; Mechanical degradation; THERMAL COMFORT; IMPACT;
D O I
10.1016/j.culher.2018.02.012
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
There is a particular approach to the energy performance and indoor microclimate of historic buildings. However, the implementation of energy efficiency in historic buildings is limited, given that the materials, structure, geometry and artworks to be conserved inhibit the improvement of microclimate parameters or energy performance. The main aim of this work is to study the use of environmental conditioning techniques in a historic building and its impact on the conservation of artworks prior to the refurbishment project. This study describes experimental research carried out on the church of Nuestra Senora de la Merced, a historic building in a Mediterranean climate. The building was monitored and measured to validate numerical codes using Design Builder 4.7.027 and Energy Plus 8.3. Software building models made it possible to evaluate the implementation of different environmental techniques - passive, active and combined - in the church with a view to conserving artworks. This study concluded that the use of passive environmental techniques does not completely eliminate the mechanical risk or bio-deterioration that are inherent to movable heritage. Proposals for the use of active systems in combination with passive techniques improve the initial conservation of artworks and decrease the risk of biological degradation. Although energy consumption is high due to the large size and thermal inertia of the building, consumption is considerably reduced when active and passive systems are combined. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 50 条
  • [11] Impact of radiative cooling on the energy performance of courtyards in Mediterranean climate
    Dominguez-Torres, Carlos-Antonio
    Dominguez-Delgado, Antonio
    BUILDING SIMULATION, 2024, 17 (09) : 1491 - 1513
  • [12] Energy, comfort, and environmental assessment of passive techniques integrated into low-energy residential buildings in semi-arid climate
    Mousavi, Seyedehniloufar
    Gijon-Rivera, M.
    Rivera-Solorio, C., I
    Godoy Rangel, Caribay
    ENERGY AND BUILDINGS, 2022, 263
  • [13] An approach for energy performance and indoor climate assessment in a Portuguese school building
    Bernardo, Hermano
    Antunes, Carlos Henggeler
    Gaspar, Adelio
    Pereira, Luisa Dias
    da Silva, Manuel Gameiro
    SUSTAINABLE CITIES AND SOCIETY, 2017, 30 : 184 - 194
  • [14] An Energy-Resilient Retrofit Methodology to Climate Change for Historic Districts. Application in the Mediterranean Area
    Cantatore, Elena
    Fatiguso, Fabio
    SUSTAINABILITY, 2021, 13 (03) : 1 - 33
  • [15] Field assessment of thermal comfort conditions and energy performance of social housing: The case of hot summers in the Mediterranean climate
    Escandon, Rocio
    Suarez, Rafael
    Jose Sendra, Juan
    ENERGY POLICY, 2019, 128 : 377 - 392
  • [16] Energy retrofit of historic buildings: Environmental assessment of cost-optimal solutions
    Tadeu, S.
    Rodrigues, C.
    Tadeu, A.
    Freire, F.
    Simoes, N.
    JOURNAL OF BUILDING ENGINEERING, 2015, 4 : 167 - 176
  • [17] On the assessment of the energy performance and environmental behaviour of social housing stock for the adjustment between simulated and measured data: The case of mild winters in the Mediterranean climate of southern Europe
    Escandon, Rocio
    Suarez, Rafael
    Sendra, Juan Jose
    ENERGY AND BUILDINGS, 2017, 152 : 418 - 433
  • [18] Improving Energy Performance of Historic Buildings through Hygrothermal Assessment of the Envelope
    Martin-Garin, Alexander
    Antonio Millan-Garcia, Jose
    Teres-Zubiaga, Jon
    Oregi, Xabat
    Rodriguez-Vidal, Inigo
    Bairi, Abderrahmane
    BUILDINGS, 2021, 11 (09)
  • [19] Concept, Design and Energy Performance of a Net Zero-Energy Building in Mediterranean Climate
    Ascione, Fabrizio
    Bianco, Nicola
    de Rossi, Filippo
    De Masi, Rosa Francesca
    Vanoli, Giuseppe Peter
    FOURTH INTERNATIONAL CONFERENCE ON COUNTERMEASURES TO URBAN HEAT ISLAND, (UHI 2016), 2016, 169 : 26 - 37
  • [20] Irrigation proposals for improving the energy performance of green roofs in Mediterranean climate
    Borras, Julia G.
    Lerma, Carlos
    Mas, Angeles
    Vercher, Jose
    Gil, Enrique
    JOURNAL OF BUILDING ENGINEERING, 2023, 75