Transtympanic Visualization of Cochlear Implant Placement With Optical Coherence Tomography: A Pilot Study

被引:4
作者
Wang, Junzhe [1 ]
Chawdhary, Gaurav [2 ]
Farrell, Joshua [1 ]
Yang, Xiaojie [1 ,3 ]
Farrell, Matthew [4 ]
MacDougall, Dan [4 ]
Trudel, Mathieu [5 ]
Shoman, Nael [6 ]
Morris, David P. [7 ]
Adamson, Robert B. A. [1 ,7 ,8 ]
机构
[1] Dalhousie Univ, Sch Biomed Engn, 5981 Univ Ave,POB 15000, Halifax, NS B3H 4R2, Canada
[2] Royal Hallamshire Hosp, Dept Otolaryngol, Sheffield, S Yorkshire, England
[3] Southern Univ Sci & Technol, Dept Biomed Engn, Shenzhen, Guangdong, Peoples R China
[4] Audiopt Med Inc, Halifax, NS, Canada
[5] CHU Quebec Univ Laval, Dept Otolaryngol Head & Neck Surg, Quebec City, PQ, Canada
[6] Dalhousie Univ, Dept Otolaryngol Head & Neck Surg, Halifax, NS, Canada
[7] Dalhousie Univ, Dept Surg, Div Otolaryngol Head & Neck Surg, Halifax, NS, Canada
[8] Dalhousie Univ, Elect & Comp Engn Dept, Halifax, NS, Canada
关键词
Cochlear implant; Noninvasive imaging; Nonradiation imaging; Optical coherence tomography; Point-of-care; Postsurgical monitoring; MIDDLE-EAR; VIBROMETRY;
D O I
10.1097/MAO.0000000000003635
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective This study aimed to evaluate the ability of transtympanic middle ear optical coherence tomography (ME-OCT) to assess placement of cochlear implants (CIs) in situ. Patient A 72-year-old man with bilateral progressive heredodegenerative sensorineural hearing loss due to work-related noise exposure received a CI with a slim modiolar electrode for his right ear 3 months before his scheduled checkup. Intervention A custom-built swept source ME-OCT system (lambda(o) = 1550 nm, increment lambda = 40 nm) designed for transtympanic middle ear imaging was used to capture a series of two- and three-dimensional images of the patient's CI in situ. Separately, transtympanic OCT two-dimensional video imaging and three-dimensional imaging were used to visualize insertion and removal of a CI with a slim modiolar electrode in a human cadaveric temporal bone through a posterior tympanotomy. Main Outcome Measure Images and video were analyzed qualitatively to determine the visibility of implant features under ME-OCT imaging and quantitatively to determine insertion depth of the CI. Results After implantation, the CI electrode could be readily visualized in the round window niche under transtympanic ME-OCT in both the patient and the temporal bone. In both cases, characteristic design features of the slim modiolar electrode allowed us to quantify the insertion depth from our images. Conclusions ME-OCT could potentially be used in a clinic as a noninvasive, nonionizing means to confirm implant placement. This study shows that features of the CI electrode visible under ME-OCT can be used to quantify insertion depth in the postoperative ear.
引用
收藏
页码:E824 / E828
页数:5
相关论文
共 35 条
  • [1] Arweiler-Harbeck D., 2012, ISRN OTOLARYNGOL, V2012, P1
  • [2] Cochlear implantation outcomes in adults: A scoping review
    Boisvert, Isabelle
    Reis, Mariana
    Au, Agnes
    Cowan, Robert
    Dowell, Richard C.
    [J]. PLOS ONE, 2020, 15 (05):
  • [3] Revealing the morphology and function of the cochlea and middle ear with optical coherence tomography
    Burwood, George W. S.
    Fridberger, Anders
    Wang, Ruikang K.
    Nuttall, Alfred L.
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (05) : 858 - 881
  • [4] Utilization potential of intraluminal optical coherence tomography for the Eustachian tube
    Byun, Hayoung
    Kim, Yeon Hoon
    Xing, Jingchao
    Shin, Su-Jin
    Lee, Seung Hwan
    Yoo, Hongki
    Chung, Jae Ho
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [5] Cochlear Ltd, 2020, Nucleus ® CI632 cochlear implant with slim Modiolar electrode: physicians guide
  • [6] Standardization of CT Depiction of Cochlear Implant Insertion Depth
    Colby, C. C.
    Todd, N. W.
    Harnsberger, H. R.
    Hudgins, P. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 368 - 371
  • [7] Cochlear Implantation: An Overview
    Deep, Nicholas L.
    Dowling, Eric M.
    Jethanamest, Daniel
    Carlson, Matthew L.
    [J]. JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2019, 80 (02) : 169 - 177
  • [8] Entwisle Lavin K., 2018, Seminars in Hearing, V39, P390, DOI 10.1055/s-0038-1670705
  • [9] Effectiveness of skull X-RAY to determine cochlear implant insertion depth
    Fernandes, Vinay
    Wang, Yiqiao
    Yeung, Robert
    Symons, Sean
    Lin, Vincent
    [J]. JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2018, 47
  • [10] Radio logic and Functional Evaluation of Electrode Dislocation from the Scala Tympani to the Scala Vestibuli in Patients with Cochlear Implants
    Fischer, N.
    Pinggera, L.
    Weichbold, V.
    Dejaco, D.
    Schmutzhard, J.
    Widmann, G.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 372 - 377