Cost comparison of printed circuit heat exchanger to low cost periodic flow regenerator for use as recuperator in a s-CO2 Brayton cycle

被引:47
作者
Hinze, Jacob F. [1 ]
Nellis, Gregory F. [2 ]
Anderson, Mark H. [3 ]
机构
[1] Univ Wisconsin, 1500 Engn Dr,1335 Engn Res Bldg, Madison, WI 53706 USA
[2] Univ Wisconsin, 1500 Engn Dr,1303 Engn Res Bldg, Madison, WI USA
[3] Univ Wisconsin, 1500 Engn Dr,737 Engn Res Bldg, Madison, WI USA
关键词
Supercritical CO2; Brayton; Regenerator; Recuperator;
D O I
10.1016/j.apenergy.2017.09.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Supercritical Carbon Dioxide (sCO(2)) power cycles have the potential to deliver high efficiency at low cost. However, in order for an sCO(2) cycle to reach high efficiency, highly effective recuperators are needed. These recuperative heat exchangers must transfer heat at a rate that is substantially larger than the heat transfer to the cycle itself and can therefore represent a significant portion of the power block costs. Regenerators are proposed as a cost saving alternative to high cost printed circuit recuperators for this application. A regenerator is an indirect heat exchanger which periodically stores and releases heat to the working fluid. The simple design of a regenerator can be made more inexpensively compared to current options. The objective of this paper is a detailed evaluation of regenerators as a competing technology for recuperators within an sCO(2) Brayton cycle. The level of the analysis presented here is sufficient to identify issues with the regenerator system in order to direct future work and also to clarify the potential advantage of pursuing this technology. A reduced order model of a regenerator is implemented into a cycle model of an sCO(2) Brayton cycle. An economic analysis investigates the cost savings that is possible by switching from recuperative heat exchangers to switched-bed regenerators. The cost of the regenerators was estimated using the amount of material required if the pressure vessel is sized using ASME Boiler Pressure Vessel Code (BPVC) requirements. The cost of the associated valves is found to be substantial for the regenerator system and is estimated in collaboration with an industrial valve supplier. The result of this analysis suggests that a 21.2% reduction in the contribution to the Levelized Cost of Electricity (LCoE) from the power block can be realized by switching to a regenerator-based system.
引用
收藏
页码:1150 / 1161
页数:12
相关论文
共 29 条
[1]  
[Anonymous], 1995, RENEW ENERG
[2]  
[Anonymous], 2007, AM SOC MECH ENG B PV
[3]  
Barron RF, 2016, Cryogenic heat transfer, Second
[4]  
Beer FP., 2012, MECH MAT
[5]  
Carlson MD., 2016, 5 INT S SUPERCRIT CO, P1
[6]   Dry-Cooled Supercritical CO2 Power for Advanced Nuclear Reactors [J].
Conboy, T. M. ;
Carlson, M. D. ;
Rochau, G. E. .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2015, 137 (01)
[7]  
Dragutinovic G.D., 1998, OPERATION COUNTERFLO
[8]  
Driscoll MJ., 2004, SUPERCRITICAL CO2 PL
[9]  
Dyreby JJ, 2014, MODELING SUPERCRITIC
[10]  
El-Wakil MM., 2013, POWERPLANT TECHNOLOG, V1st