Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study

被引:2
|
作者
Stubig, T. [1 ]
Aidarous, H. [1 ]
Khalifa, A. [1 ]
Omar, M. [1 ]
Krettek, C. [1 ]
Pacha, T. Omar [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
3D imaging; Femur fractures; Antetorsion measurements; Rotational alignement; Intraoperative imaging; COMPUTER-NAVIGATION; SYSTEM;
D O I
10.1007/s00402-020-03432-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim This study aims to test the accuracy and feasibility of a measurement of femoral torsion of a 3D C-arm system (Linea aspera method) in a cadaver setting. Materials and methods A total of 11 intact femora were used. Schanz screws were inserted in the femoral bone in a parallel manner with the help of a fixed drill sleeve. Femur bones were then fractured in a controlled manner and three different internal and external torsion angles were fixed with the help of a Goniometer. After that, a 3D scan was performed. The 3D data set was analyzed using a radiologic software (Visage 7, Visage Imaging Inc, USA). Measurements were then compared in the two methods with a dependent t test. Results Specific measurements for different angles did not show any differences between those two utilities. Conclusion Intraoperative estimation of femoral antetorsion using a 3D C-Arm system and the Linea aspera method seems to be an accurate and feasible method. Nevertheless, more studies with higher patient numbers, comparison to CT seems to be the next step and can be recommended.
引用
收藏
页码:1739 / 1743
页数:5
相关论文
共 19 条
  • [1] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743
  • [2] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [3] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    SPINE, 2018, 43 (05) : 370 - 377
  • [4] C-arm as intraoperative control in reduction of isolated zygomatic arch fractures: a randomized clinical trial
    Pedemonte C.
    Sáez F.
    Vargas I.
    González E.
    Canales M.
    Lazo D.
    Pérez H.
    Oral and Maxillofacial Surgery, 2016, 20 (1) : 79 - 83
  • [5] The Method of 3D C-arm Navigated AC Joint Stabilization-Surgical Technique
    Boehringer, Alexander
    Pankratz, Carlos
    Eickhoff, Alexander
    Gebhard, Florian
    Schuetze, Konrad
    SURGICAL TECHNIQUES DEVELOPMENT, 2024, 13 (02): : 214 - 226
  • [6] 3D C-arm navigated suture button implantation for AC joint dislocations - the pilot study
    Boehringer, Alexander
    Gebhard, Florian
    Dehner, Christoph
    Eickhoff, Alexander
    Cintean, Raffael
    Pankratz, Carlos
    Schuetze, Konrad
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (05) : 2431 - 2439
  • [7] Automated Digital Image Optimisation in Intraoperative 2D and 3D Imaging Using a Mobile C-Arm With Flat-Panel Detector
    Groh, J.
    Perl, M.
    Braeuer, L.
    Stadthalter, H.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2025, 21 (02):
  • [8] 3D Reconstruction of Wrist Bones from C-Arm Fluoroscopy Using Planar Markers
    Shrestha, Pragyan
    Xie, Chun
    Shishido, Hidehiko
    Yoshii, Yuichi
    Kitahara, Itaru
    DIAGNOSTICS, 2023, 13 (02)
  • [9] Radiation exposure of a mobile 3D C-arm with large flat-panel detector for intraoperative imaging and navigation - an experimental study using an anthropomorphic Alderson phantom
    Yashar Naseri
    Ulrich Hubbe
    Christoph Scholz
    Johannes Brönner
    Marie T. Krüger
    Jan-Helge Klingler
    BMC Medical Imaging, 20
  • [10] Radiation exposure of a mobile 3D C-arm with large flat-panel detector for intraoperative imaging and navigation-an experimental study using an anthropomorphic Alderson phantom
    Naseri, Yashar
    Hubbe, Ulrich
    Scholz, Christoph
    Broenner, Johannes
    Krueger, Marie T.
    Klingler, Jan-Helge
    BMC MEDICAL IMAGING, 2020, 20 (01)