Assessment of an ECG-Based System for Localizing Ventricular Arrhythmias in Patients With Structural Heart Disease

被引:7
作者
Zhou, Shijie [1 ]
AbdelWahab, Amir [2 ]
Sapp, John L. [2 ,4 ]
Sung, Eric [1 ,6 ]
Aronis, Konstantinos N. [3 ,6 ]
Warren, James W. [4 ]
MacInnis, Paul J. [4 ]
Shah, Rushil [3 ]
Horacek, B. Milan [5 ]
Berger, Ronald [1 ,3 ]
Tandri, Harikrishna [1 ,3 ]
Trayanova, Natalia A. [1 ,6 ]
Chrispin, Jonathan [1 ,3 ]
机构
[1] Johns Hopkins Univ, Alliance Cardiovasc Diagnost & Treatment Innovat, Hackerman Hall,Suite 218,3400 North Charles St, Baltimore, MD 21218 USA
[2] Queen Elizabeth 2 Hlth Sci Ctr, Dept Med, Halifax, NS, Canada
[3] Johns Hopkins Univ Hosp, Dept Med, Div Cardiol, Sect Cardiac Electrophysiol, Baltimore, MD 21287 USA
[4] Dalhousie Univ, Dept Physiol & Biophys, Halifax, NS, Canada
[5] Dalhousie Univ, Sch Biomed Engn, Halifax, NS, Canada
[6] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2021年 / 10卷 / 20期
基金
美国国家卫生研究院;
关键词
ECG; pace-mapping; premature ventricular contraction (PVC); radiofrequency (RF) ablation; structural heart disease (SHD); ventricular tachycardia (VT); 12-LEAD ELECTROCARDIOGRAM; CATHETER ABLATION; TACHYCARDIA; ACCESS; SITE;
D O I
10.1161/JAHA.121.022217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We have previously developed an intraprocedural automatic arrhythmia-origin localization (AAOL) system to identify idiopathic ventricular arrhythmia origins in real time using a 3-lead ECG. The objective was to assess the localization accuracy of ventricular tachycardia (VT) exit and premature ventricular contraction (PVC) origin sites in patients with structural heart disease using the AAOL system. Methods and Results In retrospective and prospective case series studies, a total of 42 patients who underwent VT/PVC ablation in the setting of structural heart disease were recruited at 2 different centers. The AAOL system combines 120-ms QRS integrals of 3 leads (III, V2, V6) with pace mapping to predict VT exit/PVC origin site and projects that site onto the patient-specific electroanatomic mapping surface. VT exit/PVC origin sites were clinically identified by activation mapping and/or pace mapping. The localization error of the VT exit/PVC origin site was assessed by the distance between the clinically identified site and the estimated site. In the retrospective study of 19 patients with structural heart disease, the AAOL system achieved a mean localization accuracy of 6.5 +/- 2.6 mm for 25 induced VTs. In the prospective study with 23 patients, mean localization accuracy was 5.9 +/- 2.6 mm for 26 VT exit and PVC origin sites. There was no difference in mean localization error in epicardial sites compared with endocardial sites using the AAOL system (6.0 versus 5.8 mm, P=0.895). Conclusions The AAOL system achieved accurate localization of VT exit/PVC origin sites in patients with structural heart disease; its performance is superior to current systems, and thus, it promises to have potential clinical utility.
引用
收藏
页数:13
相关论文
共 20 条
[1]   Learning Domain Shift in Simulated and Clinical Data: Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms [J].
Alawad, Mohammed ;
Wang, Linwei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (05) :1172-1184
[2]   Isolated potentials during sinus rhythm and pace-mapping within scars as guides for ablation of post-infarction ventricular tachycardia [J].
Bogun, F ;
Good, E ;
Reich, S ;
Elmouchi, D ;
Igic, P ;
Lemola, K ;
Tschopp, D ;
Jongnarangsin, K ;
Oral, H ;
Chugh, A ;
Pelosi, F ;
Morady, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) :2013-2019
[3]  
Dixit Sanjay, 2002, Card Electrophysiol Rev, V6, P436, DOI 10.1023/A:1021196627551
[4]   Sequential Factorized Autoencoder for Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms [J].
Gyawali, Prashnna Kumar ;
Horacek, B. Milan ;
Sapp, John L. ;
Wang, Linwei .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (05) :1505-1516
[5]   Localization of origins of premature ventricular contraction in the whole ventricle based on machine learning and automatic beat recognition from 12-lead ECG [J].
He, Kaiyue ;
Nie, Zhenning ;
Zhong, Gaoyan ;
Yang, Cuiwei ;
Sun, Jian .
PHYSIOLOGICAL MEASUREMENT, 2020, 41 (05)
[6]   Anterior pericardial access to facilitate electrophysiology study and catheter ablation of ventricular arrhythmias: A single tertiary center experience [J].
Keramati, Ali R. ;
DeMazumder, Deeptankar ;
Misra, Satish ;
Chrispin, Jonathan ;
Assis, Fabrizio R. ;
Raghuram, Chava ;
Dey, Swati ;
Calkins, Hugh ;
Tandri, Harikrishna .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (10) :1189-1195
[7]   Proof of concept study of a novel pacemapping algorithm as a basis to guide ablation of ventricular arrhythmias [J].
Li, Anthony ;
Davis, Joseph Samuel ;
Grimster, Alexander ;
Wierwille, Jeremiah ;
Herold, Keith ;
Morgan, Dennis ;
Behr, Elijah R. ;
Shorofsky, Stephen ;
Saba, Magdi .
EUROPACE, 2018, 20 (10) :1647-1656
[8]   RELATIONSHIP BETWEEN THE 12-LEAD ELECTROCARDIOGRAM DURING VENTRICULAR-TACHYCARDIA AND ENDOCARDIAL SITE OF ORIGIN IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
MILLER, JM ;
MARCHLINSKI, FE ;
BUXTON, AE ;
JOSEPHSON, ME .
CIRCULATION, 1988, 77 (04) :759-766
[9]   Catheter Ablation of Idiopathic Ventricular Arrhythmias [J].
Pathak, Rajeev K. ;
Ariyarathna, Nilshan ;
Garcia, Fermin C. ;
Sanders, Prashanthan ;
Marchlinski, Francis E. .
HEART LUNG AND CIRCULATION, 2019, 28 (01) :102-109
[10]  
Sapp John L, 2017, JACC Clin Electrophysiol, V3, P687, DOI 10.1016/j.jacep.2017.02.024