Effect of residual noise level on reproducibility of the signal-averaged ECG

被引:3
|
作者
Christiansen, EH
Frost, L
Molgaard, H
Nielsen, TT
Pedersen, AK
机构
[1] Department of Cardiology, Skejby Sygehus, University Hospital, Aarhus
[2] Department of Cardiology, Skejby Sygehus, University Hospital
关键词
reproducibility; signal averaging; late potentials; signal processing; noise reduction; electro cardiography;
D O I
10.1016/S0022-0736(96)80086-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Late potentials are detected at various noise levels in clinical studies. The aim of this study was to assess the effect of residual noise level on the reproducibility of the signal-averaged electrocardiogram (EGG). Two consecutive raw 15-minute ECG from each of 188 patients with coronary artery disease were digitized and stored on optical discs. Each raw ECG was analyzed by two signal-averaging procedures to noise level 0.2 mu V or 0.4 mu V. Standard time-domain parameters were measured: QRS duration (SA-QRS), late potential (LP) duration, and root-mean-square voltage of the terminal 40 ms of the filtered QRS (RMS40). The SA-QRS was prolonged by 12 +/- 14 ms by the reduction in noise level from 0.4 mu V to 0.2 mu V, LP duration was prolonged by 10 +/- 10 ms, and RMS40 was reduced by 19 +/- 22 mu V. The temporal variation of the measured SA-QRS from ECG1 to ECG2 was significantly lower at noise level 0.2 mu V (9 +/- 13 ms) than at noise level 0.4 mu V (13 +/- 14 ms) (P < .001). The LP duration was also more stable at noise level 0.2 mu V than al noise level 0.4 mu V (0.5 +/- 11 ms vs 2 +/- 13 ms, P < .05). The presence of any two of three abnormal parameters (SA-QRS >120 ms, RMS40 < 25 mu V, LP duration > 40 ms) was used as the criterion for the presence of LPs. At noise level 0.4 mu V, the proportion of patients with diagnosed LPs in ECG1 was 25% and at noise level 0.2 mu V it was 62%. At noise level 0.4 mu V, 20% were reclassified from LP-negative in ECG1 to LP-positive in ECG2, and 7% were reclassified from LP-positive in ECG1 to LP-negative in ECG2. At noise level 0.2 mu V, 20% were reclassified from LP-negative in ECG1 to LP-positive in ECG2, and 9% were reclassified from LP-positive in ECG1 Co LP-negative in ECG2. It was concluded that (1) the diagnosis of LPs is significantly dependent on the extent of noise reduction by signal averaging; and (2) the numerical reproducibility of signal-averaged QRS duration and LP duration is lower at noise level 0.4 mu V then at noise level 0.2 mu V; and the diagnostic reproducibility of LPs is similar at both noise levels.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 50 条
  • [41] VALUE OF THE SIGNAL-AVERAGED ECG IN PATIENTS WITH ARRHYTHMOGENIC RIGHT VENTRICULAR DISEASE
    WICHTER, T
    MARTINEZRUBIO, A
    CIRCULATION, 1992, 86 (04) : 319 - 319
  • [42] ADVANCED TIME-FREQUENCY METHODS FOR SIGNAL-AVERAGED ECG ANALYSIS
    JONES, DL
    TOUVANNAS, JS
    LANDER, P
    ALBERT, DE
    JOURNAL OF ELECTROCARDIOLOGY, 1993, 25 : 188 - 194
  • [43] Signal-averaged electrocardiography
    Cain, ME
    Mason, JW
    Anderson, JL
    Sheinman, MM
    Arnsdorf, MF
    Waldo, AL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (01) : 238 - 249
  • [44] Late effects of anthracycline therapy in childhood on signal-averaged ECG parameters
    Mladosievicova, B
    Foltinova, A
    Petrasova, H
    Hulin, I
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2000, 5 (04) : 411 - 414
  • [45] Prediction of arrhythmia risk based on signal-averaged ECG in postinfarction patients
    Borggrefe, M
    Fetsch, T
    MartinezRubio, A
    Makijarvi, M
    Breithardt, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (10): : 2566 - 2576
  • [46] COMPARISON OF TECHNIQUES FOR ANALYSIS OF THE P-WAVE SIGNAL-AVERAGED ECG
    STEINBERG, JS
    KORENSTEIN, D
    CIRCULATION, 1993, 88 (04) : 311 - 311
  • [47] Effect of parasympathetic blockade on the signal-averaged electrocardiogram
    Christiansen, EH
    Frobert, O
    CLINICAL AUTONOMIC RESEARCH, 1998, 8 (03) : 165 - 171
  • [48] THE INFLUENCE OF PRAJMALINE AND TOCAINIDE ON THE SIGNAL-AVERAGED ECG - A COMPARATIVE-STUDY
    GOEDELMEINEN, L
    HOFMANN, M
    SCHMIDT, G
    MAIERRUDOLPH, W
    BARTHEL, P
    BAEDEKER, W
    BLOMER, H
    HERZ KREISLAUF, 1989, 21 (12): : 515 - 519
  • [49] Reduction of electromyographic noise in the signal-averaged electrocardiogram by spectral decomposition
    Barbosa, PRB
    Barbosa-Filho, J
    de Sá, CAM
    Barbosa, EC
    Nadal, J
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (01) : 114 - 117
  • [50] Effect of Hemodialysis on the signal-averaged electrocardiogram(SAECG).
    Kim, HY
    Kwon, SG
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 487A - 487A